Flat Flexible Cable

Flexible copper conductors are made from high conductivity Copper rods of 8 mm diameter. The rod is drawn to required sizes of fine wires for the construction of conductors of different areas of cross section. Annealed plain copper conductors used in the flexible cables. The construction of conductor is also made according to customer specification.
View Complete Details

Flexible Power Cable

  • Nominal Area in Sq. mm. 1.50
  • Nos. & Dia. of wire Nos. / mm 22/0.30
Meets the requirement of CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.Designed for heavy duty use. Cur, tear & abrasion resistant. Exceptional long term performance. Excellent resistant to oils, chemicals, ozone & solvents.
View Complete Details

Flexible Copper Cables

  • Nominal Area in Sq. mm. 1.50
  • Nos. & Dia. of wire Nos. / mm 30/0.25
Flexible copper conductors are made from high conductivity Copper rods of 8 mm diameter. The rod is drawn to required sizes of fine wires for the construction of conductors of different areas of cross section. Annealed plain copper conductors used in the flexible cables. The construction of conductor is also made according to customer specification.
View Complete Details

Copper Welding Cable

  • Cross - Sectional area mm2 10
  • Max. Conductor resistance at 200C 1.91ohm/km
Welding : Designed for the secondary (high current) connection to automatic or hand held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines and conveyor systems, in machine tool and automatically operated line and spot welding machines.Power : Earthingreturn leads, power feeds to electrolytic plating process, Busbar connection, transformers, generators, aircraft servicing equipments etc.Based on CENELEC HD 22-6 31, VDE 0282 , IEC 245-6, IS 473, BS 638-4.
View Complete Details

Rubber 4 Core Round Cables

FEATURES & PROPERTIES :
Meets the requirement of CENELEC HD 22.1.S2, DIN
VDE 0282PART 810, IEC 245, CEI 20-19 & BS6007, BS 6899.
Designed for heavy duty use.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils, acids, chemicals,
ozone &solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize Rubber.
Excellent Electrical Properties.

APPLICATION :
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
CONSTRUCTION :
Conductor :Finely stranded bare copper flexible conductor.
Insulation :Oil & water resistant thermoplastic rubber,
Sheath :Black heavy duty thermoplastic rubber.
Core Colours :4core: Red, Yellow, Blue, Green Or BlackOR4core: Black, Light Blue, Brown, Yellow with green lineOr Green with yellow line

CONDUCTOR RUBBER INSULATION TOTAL THICKNESS OF DOUBLE RUBBER SHEATH Conductor Resistance at 20°C (max) ohms/km CURRENT 
Rating at 
40°C
Amps.
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Nominal 
Core Dia.
Nominal 
Thickness
Approx. Overall 
Dimensions
Sq. mm. Nos. / mm mm mm mm
mm
1.50 22/0.30 0.80 3.25 1.50 10.80 12.10 14
2.50 36/0.30 0.90 3.84 1.65 12.50 7.41 18
4.00 56/0.30 1.00 4.50 1.65 14.10 4.95 26
6.00 85/0.30 1.00 5.30 1.65 16.00 3.30 31
10.00 140/0.30 1.00 6.50 2.00 20.35 1.91 42
16.00 226/0.30 1.00 8.00 2.00 23.40 1.21 57
25.00 354/0.30 1.20 10.10 2.20 28.80 0.780 72
35.00 495/0.30 1.20 11.50 2.20 31.50 0.554 90
50.00 703/0.30 1.40 13.60 2.30 37.30 0.386 115
70.00 440/0.30 1.40 15.30 2.60 42.20 0.272 143
95.00 475/0.50 1.60 18.00 2.65 48.80 0.206 165









View Complete Details

DRINCABLE

FEATURES & PROPERTIES :
Meets the requirement of CENELEC HD 22.1.S2, DIN VDE 0282PART 810, IEC 245, CEI 20-19 & BS6007, BS 6899.
Designed for heavy duty use.
Non toxic cable.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils, chemicals,
ozone, solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize Rubber.
Excellent Electrical Properties.

APPLICATION :
Cables for drinking water.
CONSTRUCTION :

Conductor :Finely stranded bare copper flexible conductor.
Insulation :Water resistant EPDM base rubber,
Sheath :Black heavy duty EPDM base rubber.
Core Colours :4core: Black, Light Blue, Brown, Yellowwith green line Or Green with yellow lineOR4core: Red , Yellow Blue, Green Or Black

CONDUCTOR RUBBER INSULATION RUBBER SHEATH Conductor Resistance at 20°C (max) ohms/km CURRENT 
Rating at 
40°C
Amps.
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Nominal 
Core Dia.
Nominal 
Thickness
Approx. Overall 
Dimensions
Sq. mm. Nos. / mm mm mm mm Thickness
mm
Width 
mm
1.50 22/0.30 0.80 3.25 1.15 6.00 12.80 12.10 14
2.50 36/0.30 0.90 3.84 1.15 6.40 14.60 7.41 18
4.00 56/0.30 1.00 4.50 1.15 7.40 16.80 4.95 26
6.00 85/0.30 1.00 5.30 1.15 7.90 18.70 3.30 31
10.00 140/0.30 1.00 6.50 1.40 9.90 23.70 1.91 42
16.00 226/0.30 1.00 8.00 1.40 11.40 28.00 1.21 57
25.00 354/0.30 1.20 10.10 2.00 14.70 35.50 0.780 72
35.00 495/0.30 1.20 11.30 2.00 16.20 39.50 0.554 90
50.00 703/0.30 1.40 13.60 2.20 18.30 45.50 0.386 115
70.00 440/0.45 1.40 15.30 2.20 20.00 51.00 0.272 143
95.00 475/0.50 1.60 18.00 2.40 23.50 60.00 0.206 165










View Complete Details

H07RN Submersible Pump Cables

CABLE DESIGN:Submersible Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Jainson is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability

Technical Details :Rubber Sheathed cable CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.

FEATURES & PROPERTIES :Designed for heavy duty use.Cur, tear & abrasion resistant.Exceptional long term performance.Excellent resistant to oils, chemicals, ozone &solvents.Excellent Impact Resistant.Excellent Weather Resistant.Performs & Looks like Vulcanize Rubber.Excellent Electrical Properties.Temperature range -40 to +90
APPLICATION :
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
CONSTRUCTION :
Conductor :Plain annealed flexible copper
Insulation :EPR
Sheath/Jacket :PCP Or Synthetic Rubber (Oil resistant & flame retardant)
Core Colours :3core : Brown, Blue & Green / Yellow4core : Brown, Blue, Black & Green / Yellow

CONDUCTOR PVC INSULATION TOTAL THICKNESS OF DOUBLE PVC SHEATH
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Mean Overall Diameter
Lower Limit Upper Limit
Sq. mm. Nos. / mm mm mm
mm
1.50 22/0.30 0.80 09.20 11.90
2.50 36/0.30 0.90 10.90 14.00
4.00 56/0.30 1.00 12.70 16.20
6.00 85/0.30 1.00 14.10 18.00
10.00 140/0.30 1.20 19.10 24.20
16.00 226/0.30 1.20 21.80 27.60
25.00 354/0.30 1.40 26.10 33.00
35.00 495/0.30 1.40 29.30 37.10
50.00 703/0.30 1.60 34.10 42.90
70.00 440/0.45 1.60 38.40 48.30
95.00 475/0.50 1.80 43.30 54.00
RUBBER 4CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (450/750 VOLTS)
CONDUCTOR PVC INSULATION TOTAL THICKNESS OF DOUBLE PVC SHEATH
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Mean Overall Diameter
Lower Limit Upper Limit
Sq. mm. Nos. / mm mm mm
mm
1.50 22/0.30 0.80 10.20 13.10
2.50 36/0.30 0.90 12.10 15.50
4.00 56/0.30 1.00 14.00 17.90
6.00 85/0.30 1.00 15.70 20.00
10.00 140/0.30 1.20 20.90 26.50
16.00 226/0.30 1.20 23.80 30.10
25.00 354/0.30 1.40 28.90 36.60
35.00 495/0.30 1.40 32.50 41.10
50.00 703/0.30 1.60 37.70 47.50
70.00 440/0.45 1.60 42.70 54.00
95.00 475/0.50 1.80 48.40 61.00








View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Electrical Cables & Wires from Ahmedabad, Gujarat by jainson cable india pvt ltd
Post Buy Requirement
JC
Ahmedabad, Gujarat, India
Add Review

Electrical Cables & Wires #1779217

Flat Flexible Cable

Flexible copper conductors are made from high conductivity Copper rods of 8 mm diameter. The rod is drawn to required sizes of fine wires for the construction of conductors of different areas of cross section. Annealed plain copper conductors used in the flexible cables. The construction of conductor is also made according to customer specification.
View Complete Details

Flexible Power Cable

  • Nominal Area in Sq. mm. 1.50
  • Nos. & Dia. of wire Nos. / mm 22/0.30
Meets the requirement of CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.Designed for heavy duty use. Cur, tear & abrasion resistant. Exceptional long term performance. Excellent resistant to oils, chemicals, ozone & solvents.
View Complete Details

Flexible Copper Cables

  • Nominal Area in Sq. mm. 1.50
  • Nos. & Dia. of wire Nos. / mm 30/0.25
Flexible copper conductors are made from high conductivity Copper rods of 8 mm diameter. The rod is drawn to required sizes of fine wires for the construction of conductors of different areas of cross section. Annealed plain copper conductors used in the flexible cables. The construction of conductor is also made according to customer specification.
View Complete Details

Copper Welding Cable

  • Cross - Sectional area mm2 10
  • Max. Conductor resistance at 200C 1.91ohm/km
Welding : Designed for the secondary (high current) connection to automatic or hand held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines and conveyor systems, in machine tool and automatically operated line and spot welding machines.Power : Earthingreturn leads, power feeds to electrolytic plating process, Busbar connection, transformers, generators, aircraft servicing equipments etc.Based on CENELEC HD 22-6 31, VDE 0282 , IEC 245-6, IS 473, BS 638-4.
View Complete Details

Rubber 4 Core Round Cables

FEATURES & PROPERTIES :
Meets the requirement of CENELEC HD 22.1.S2, DIN
VDE 0282PART 810, IEC 245, CEI 20-19 & BS6007, BS 6899.
Designed for heavy duty use.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils, acids, chemicals,
ozone &solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize Rubber.
Excellent Electrical Properties.

APPLICATION :
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
CONSTRUCTION :
Conductor :Finely stranded bare copper flexible conductor.
Insulation :Oil & water resistant thermoplastic rubber,
Sheath :Black heavy duty thermoplastic rubber.
Core Colours :4core: Red, Yellow, Blue, Green Or BlackOR4core: Black, Light Blue, Brown, Yellow with green lineOr Green with yellow line

CONDUCTOR RUBBER INSULATION TOTAL THICKNESS OF DOUBLE RUBBER SHEATH Conductor Resistance at 20°C (max) ohms/km CURRENT 
Rating at 
40°C
Amps.
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Nominal 
Core Dia.
Nominal 
Thickness
Approx. Overall 
Dimensions
Sq. mm. Nos. / mm mm mm mm
mm
1.50 22/0.30 0.80 3.25 1.50 10.80 12.10 14
2.50 36/0.30 0.90 3.84 1.65 12.50 7.41 18
4.00 56/0.30 1.00 4.50 1.65 14.10 4.95 26
6.00 85/0.30 1.00 5.30 1.65 16.00 3.30 31
10.00 140/0.30 1.00 6.50 2.00 20.35 1.91 42
16.00 226/0.30 1.00 8.00 2.00 23.40 1.21 57
25.00 354/0.30 1.20 10.10 2.20 28.80 0.780 72
35.00 495/0.30 1.20 11.50 2.20 31.50 0.554 90
50.00 703/0.30 1.40 13.60 2.30 37.30 0.386 115
70.00 440/0.30 1.40 15.30 2.60 42.20 0.272 143
95.00 475/0.50 1.60 18.00 2.65 48.80 0.206 165









View Complete Details

DRINCABLE

FEATURES & PROPERTIES :
Meets the requirement of CENELEC HD 22.1.S2, DIN VDE 0282PART 810, IEC 245, CEI 20-19 & BS6007, BS 6899.
Designed for heavy duty use.
Non toxic cable.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils, chemicals,
ozone, solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize Rubber.
Excellent Electrical Properties.

APPLICATION :
Cables for drinking water.
CONSTRUCTION :

Conductor :Finely stranded bare copper flexible conductor.
Insulation :Water resistant EPDM base rubber,
Sheath :Black heavy duty EPDM base rubber.
Core Colours :4core: Black, Light Blue, Brown, Yellowwith green line Or Green with yellow lineOR4core: Red , Yellow Blue, Green Or Black

CONDUCTOR RUBBER INSULATION RUBBER SHEATH Conductor Resistance at 20°C (max) ohms/km CURRENT 
Rating at 
40°C
Amps.
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Nominal 
Core Dia.
Nominal 
Thickness
Approx. Overall 
Dimensions
Sq. mm. Nos. / mm mm mm mm Thickness
mm
Width 
mm
1.50 22/0.30 0.80 3.25 1.15 6.00 12.80 12.10 14
2.50 36/0.30 0.90 3.84 1.15 6.40 14.60 7.41 18
4.00 56/0.30 1.00 4.50 1.15 7.40 16.80 4.95 26
6.00 85/0.30 1.00 5.30 1.15 7.90 18.70 3.30 31
10.00 140/0.30 1.00 6.50 1.40 9.90 23.70 1.91 42
16.00 226/0.30 1.00 8.00 1.40 11.40 28.00 1.21 57
25.00 354/0.30 1.20 10.10 2.00 14.70 35.50 0.780 72
35.00 495/0.30 1.20 11.30 2.00 16.20 39.50 0.554 90
50.00 703/0.30 1.40 13.60 2.20 18.30 45.50 0.386 115
70.00 440/0.45 1.40 15.30 2.20 20.00 51.00 0.272 143
95.00 475/0.50 1.60 18.00 2.40 23.50 60.00 0.206 165










View Complete Details

H07RN Submersible Pump Cables

CABLE DESIGN:Submersible Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Jainson is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability

Technical Details :Rubber Sheathed cable CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.

FEATURES & PROPERTIES :Designed for heavy duty use.Cur, tear & abrasion resistant.Exceptional long term performance.Excellent resistant to oils, chemicals, ozone &solvents.Excellent Impact Resistant.Excellent Weather Resistant.Performs & Looks like Vulcanize Rubber.Excellent Electrical Properties.Temperature range -40 to +90
APPLICATION :
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
CONSTRUCTION :
Conductor :Plain annealed flexible copper
Insulation :EPR
Sheath/Jacket :PCP Or Synthetic Rubber (Oil resistant & flame retardant)
Core Colours :3core : Brown, Blue & Green / Yellow4core : Brown, Blue, Black & Green / Yellow

CONDUCTOR PVC INSULATION TOTAL THICKNESS OF DOUBLE PVC SHEATH
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Mean Overall Diameter
Lower Limit Upper Limit
Sq. mm. Nos. / mm mm mm
mm
1.50 22/0.30 0.80 09.20 11.90
2.50 36/0.30 0.90 10.90 14.00
4.00 56/0.30 1.00 12.70 16.20
6.00 85/0.30 1.00 14.10 18.00
10.00 140/0.30 1.20 19.10 24.20
16.00 226/0.30 1.20 21.80 27.60
25.00 354/0.30 1.40 26.10 33.00
35.00 495/0.30 1.40 29.30 37.10
50.00 703/0.30 1.60 34.10 42.90
70.00 440/0.45 1.60 38.40 48.30
95.00 475/0.50 1.80 43.30 54.00
RUBBER 4CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (450/750 VOLTS)
CONDUCTOR PVC INSULATION TOTAL THICKNESS OF DOUBLE PVC SHEATH
Nominal 
Area in 
Nos. & Dia.
of wire
Nominal 
Thickness
Mean Overall Diameter
Lower Limit Upper Limit
Sq. mm. Nos. / mm mm mm
mm
1.50 22/0.30 0.80 10.20 13.10
2.50 36/0.30 0.90 12.10 15.50
4.00 56/0.30 1.00 14.00 17.90
6.00 85/0.30 1.00 15.70 20.00
10.00 140/0.30 1.20 20.90 26.50
16.00 226/0.30 1.20 23.80 30.10
25.00 354/0.30 1.40 28.90 36.60
35.00 495/0.30 1.40 32.50 41.10
50.00 703/0.30 1.60 37.70 47.50
70.00 440/0.45 1.60 42.70 54.00
95.00 475/0.50 1.80 48.40 61.00