My ExportersIndia

For Buyer

For Seller

For Help

Hematology Analyzer

Leading Manufacturer, Supplier & Retailer of Four Channel Coagulation Analyser, 3 Part Differential Hematology Analyzer and 20 Parameters Haematology Analyzer.

Four Channel Coagulation Analyser

  • Computer Interface RS 232 Serial Port , USB
  • Power 50 Watts / 115 – 230 Volts ± 50 / 60 Hz
  • Operating Position On Horizontal Flat, Rigid and Vibration Free Surface
  • Temperature From + 18 C to 35 C
  • Relative Humidity Up to 85 %
  • Dimensions in mm (lxbxh) 345 X 300 X 140 (Approx)
  • Weight 5.4 kg (Approx)

Features
Coagulation

  • Four independent programmable coagulation channels for faster throughput.
  • Display online results of all four channels simultaneously on single screen.
  • Designed to perform all routine & special tests such as PT, APTT, TT, Fibrinogen, Factor II, V, VII, VIII, IX, X, XI, XII.
  • Uniform mixing of Sample & Reagent with magnetic stirrer.
  • Automatic sensing of sample/reagent dispensing to start the measurement.
  • Multipoint Calibration curve with user entered standard dilution % in FIB and Factor Assay.


Photometer :

  • Independent channel for Photometric assays.
  • Multipoint calibration curve with maximum 7 calibrators for Photometric assays.
  • Chromogenic assays antithrombin III (AT-III), protein C (PC), protein S (PS), D-dimer.


Common :

  • Effective temperature regulation system.
  • Robust system with built in stabilizer.
  • Storage Capacity of 250 open tests with QC and more than 2500 results.
  • Independent memory for Coagulation and Photometric mode.
  • Unique circuitry for long lamp life.
  • Human machine interface : Touchpad, Keypad.
  • Quality Control with Levey Jennings and standard deviation graphs.


Technical Specifications
Coagulation

  • Measuring System: Photometric / Mechanical
  • Optical Measurement: Photodiode
  • Measuring Volume: 150 μl
  • Sample & Reagent Mixing: With Magnetic Stirrer
  • Dry Block Incubator : 24 Positions Temperature at 37 c
  • Light Source: LED
  • Analysis Mode: PT, APTT, TT, Fibrinogen, Factor Assay (Factor II, V, VII, VIII, IX, X, XI, XII)
  • Results Displayed in: Seconds, Ratio, INR, Concentration and %


Photometer :

  • Linear Measurement Range : 0.000 to 3.000 Absorbance Units (A)
  • Photometric Accuracy : ± 2% or 0.007 Whichever is Higher, From 0 to 1.5 A, ± 3% from 1.5 A to 3.0 A
  • Optical Measurement : Photodiode
  • Cuvette Volume : 500 μl
  • Filters Interference : 405, 630 nm
  • Light Source : Tungsten Halogen
  • Warm Up Time : 90 Seconds
  • Analysis Mode : Absorbance, Kinetic, End Point, Fixed Time

Download


Download Detail File : Click Here
View Complete Details

3 Part Differential Hematology Analyzer

  • Display Color LCD with Touch Screen
  • Availability 18.5 kg. (approx)
  • Results and Histograms Display with three histograms WBC, RBC, PLT
  • Measurement Principle Electronic impedance WBC, RBC, PLT, photometric HGB
  • Measurement Chamber Dual chamber
  • Counting Modes Whole blood Predilute (with auto dispensing facility of diluent)
  • Sample Volume Whole blood mode 8 μl, Pre-dilute mode 20 μl
  • Data Storage 10, 000 results
  • Sample Type Whole blood with EDTA well homogenized, fresh sample
  • Sample Data Management Alphanumeric key 15 digits PID, Results review PID wise, Date wise
  • Patient Demography Patient Name, Age, Sex, Referred by Dr/Physician
  • Peripheral Outputs Integrated thermal printer, USB & Optional external printer
  • Diagnostic Mode User-friendly self-diagnostic mode
  • Interface USB
  • Alerts & Flagging Instrument prompts alerts on abnormality, high and low results in print and display
  • Waste Bottle With sensor for waste bottle full alarm
  • Dimensions in mm (lxbxh) 379 x 453 x 457 (approx)

Our new generation priecount with simplified operation and precise dilutor technology ensures results are of highest quality.

 

Features

  • Intuitive Software
  • Low consumable cost
  • Accurate measurement of sample by volume and time method
  • Floating discriminator
  • Innovative technology
  • High precision maintenance free dilutors
  • Easy operation and maintenance
  • Accurate and reliable results
  • Liquid level sensor for Diluent, Lyse and Rinse bottles

 

Whole Blood Linearity Range

  • WBC 0.2-99.9 x 10 /μl
  • 6 RBC 0.30-7.00 x 10 /μl
  • HGB 0.1-25.0 g/dl
  • 3 PLT upto-999 x 10 /μl
  • HCT 10.0-60 %


Operating Conditions
Power

  • 115 – 230 Volts AC 50 Hz +/- 10%
  • Proper Earthing / grounding <5 Volts
  • Power 100 VA


Environmental
Temperature

  • 18 to 40 ° C
  • Relative Humidity up to 80%

Download


Download Detail File : Click Here
View Complete Details

20 Parameters Haematology Analyzer

  • Availability 9 kg
  • Automation Grade Fully Automatic
  • Throughput 60 samples per hour
  • Sample volume < 10 μl
  • Curves RBC Curve, WBC curve, PLT curve
  • Dimensions 250 x 340 x 350 mm (W x D x H)

Download


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back