Our Products
Condition - Hard Or Annelead
Product Application Areas -Refrigeration, Air Conditioning, Thermostate, Relay.
Characteristics -A Commercially pure copper that has been deoxidized with phosphorous in such a manner as to leave a high residual phosphorous content which is not readily susceptible It has good thermal conductivity.
Packing Styles :
Technical Description
Outside Diameter in. (mm) | Inside Diameter in. (mm) | Mean Wall Thickness in. (mm) | Weight in/ft. (Kg/m) | Maximum Allowable Residue g/ft. g/m) |
---|---|---|---|---|
0.072(1.83) | 0.026(0.660) | 0.023(0.584) | 0.01373(0.0204) | 0.00020(0.000656) |
0.072(1.83) | 0.028(0.711) | 0.022(0.558) | 0.01340(0.0199) | 0.00021(0.000689) |
0.081(2.06) | 0.031(0.787) | 0.025(0.635) | 0.01705(0.0254) | 0.00023(0.000754) |
0.081(2.06) | 0.033(0.838) | 0.024(0.606) | 0.01666(0.0248) | 0.00025(0.000820) |
0.087(2.21) | 0.036(0.914) | 0.0255(0.648) | 0.01910(0.0284) | 0.00027(0.000886) |
0.087(2.21) | 0.039(0.991) | 0.024(0.606) | 0.01842(0.0239) | 0.00029(0.000951) |
0.093(2.36) | 0.042(1.07) | 0.0255(0.648) | 0.02096(0.0312) | 0.00032(0.00105) |
0.097(2.47) | 0.046(1.17) | 0.025(0.648) | 0.02221(0.0331) | 0.00035(0.00115) |
0.099(2.51) | 0.049(1.24) | 0.025(0.635) | 0.02253(0.0335) | 0.00037(0.00121) |
0.106(2.69) | 0.054(1.37) | 0.026(0.660) | 0.02533(0.0377) | 0.00041(0.00134) |
0.112(2.84) | 0.059(1.50) | 0.0265(0.673) | 0.02760(0.0411) | 0.00044(0.00144) |
0.125(3.18) | 0.064(1.63) | 0.0305(0.775) | 0.03511(0.0522) | 0.00048(0.00157) |
0.125(3.18) | 0.070(1.78) | 0.0275(0.698) | 0.03266(0.0486) | 0.00053(0.00174) |
0.125(3.18) | 0.075(1.91) | 0.025(0.635) | 0.03054(0.0454) | 0.00057(0.00187) |
0.145(3.68) | 0.080(2.03) | 0.0325(0.826) | 0.04453(0.0663) | 0.00060(0.00197) |
0.145(3.68) | 0.085(2.16) | 0.030(0.762) | 0.04202(0.0625) | 0.00064(0.00210) |
0.145(3.68) | 0.090(2.29) | 0.0275(0.698) | 0.03936(0.0586) | 0.00068(0.00223) |
0.160(4.06) | 0.100(2.54) | 0.030(0.762) | 0.04750(0.0707) | 0.00075(0.00246) |
0.160(4.06) | 0.110(2.79) | 0.025(0.635) | 0.04111(0.0611) | 0.00083(0.00272) |
0.188(4.78) | 0.120(3.03) | 0.034(0.864) | 0.06377(0.0949) | 0.00090(0.00295) |
Technical Data :
Mexflow meets the mandatory inspection requirements:
Copper Tubes :
Applicable Standard :
Copper Tubes :
Requirements as per EN 1057 :
Max Pressure
Condition | F(N/mm2) | ||||
---|---|---|---|---|---|
Anneoled O,R220 | 46 | ||||
Half-hard 1/2H.R250 | 60 | ||||
HardH,R290 | 72.5 | ||||
Flowrate Assuming good design practice and installation the maximum recommended flow velocities of oxygenated water at different temperatures are as follows : Maximum recommended flow velocities. | |||||
Degree C | 10 | 50 | 70 | 90 | |
Flowm/s | 2 | 1.5 | 1.3 | 1 |
Tolerances On Wall Thickness
Nominal Outside | Tolerance on wall thickness e” | |
---|---|---|
diameter (mm) | e < 1 mm(%) | e > 1 mm(%) |
< 18 | 10 | 13 |
> 18 | 10 | 15 |
Mechanical Properties
Material Temper | Outside Diameter in mm | Tensile Strength Mpa | Elogation % | Hardness (only indicative) Hv | ||
---|---|---|---|---|---|---|
Designated in Accordance with EN 1173 | Common Term used | Min. | Max. | Min. | Max. | - |
R220 | Annealed | 6 | 54 | 220 | 40 | (40 to 70) |
R250 | Half-hard | 6 | 67 | 250 | 30 | (75 to 100) |
- | 6 | 159 | 20 | - | ||
R290 | Hard | 6 | 267 | 290 | 3 | (min. 100) |
Indigo tubes are 100% carbon free. All tubes are cleaned and the sample tested to meet the residual requirements as specified by the codes at 0.038g/m2 (0.35g/ft2). Coils are normally furnished in ‘O60’ temper and straight lengths in H58 temper. 100% RoHS Compliance.