Post Buy Requirement
KI
Mumbai, Maharashtra, India
Add Review

Measuring Instruments & Equipment #414160

Visiguard Scattered Light Intensity Meter

The VisGuard measures the scattered light intensity of a sample drawn into the instrument. Filtered purge air is fed through the flow cell, thus enveloping the sample in a protective shroud of clean air. This effectively keeps the optics clean. Installations are either in the tunnel cavity/niches (in-situ) OR alternatively away from the area of measurement extracting the sample from the area through pipes via an external arrangement. An optional sample heater eliminates the influence of any mist effects.


APPLICATION


Dust concentration in air, oil mist detection in ship industry, machine & metal industry, visibility monitoring in rail and road tunnels





  • Easy to service, high sensitivity, stability and accuracy

  • Easy zero-point checking, even when visibility is poor

  • A special sample flow concept entirely eliminates the danger of flow cell contamination

  • Easy calibration check with checking rod, even at high dust levels

  • Continuous monitoring of visibility using scattered light principle







  • Dual-beam method

  • Operation via local control unit or central multi-channel control unit

  • Installation in tunnel tube or niche

  • Optional sample heater: Choice of measurement with/without fog compensation





SPECIFICATIONS




  • Nominal range:
    0 . 100 PLA (Polystyrol-Latex-Aerosols)
    0 . 3 E/m

  • Scale ranges: 0 . 15 10-3 E/m

  • Protection: IP65

  • Sample temperature: -20 . +50 C

  • Sample pressure: max. 3000 Pa (30 mbar)

  • Interfaces:
    RS232 or Profibus DP
    0/4 . 20 mA
    relay contacts








  • Control unit

  • Ambient environment:
    Temperature range -20 . +50C
    0 . 100% r.h.

  • Maximum service altitude 3, 000 m above sea level

  • Power supply: 85 . 264 V / 47 . 440 Hz



View Complete Details

ColorPlus - Color Measuring Equipment

he ColorPlus measures the colour/absorbance online at up to three different wavelengths in the UV and visible range, also combined. Turbidity can be compensated at the same time by selecting an appropriate wavelength. The modular design of the instrument enables to cover various applications by selecting the most suitable measuring cell. In many cases, a standard housing like e.g. Varivent is used. Alternatively, custom-specific flow cells in different materials and designs are available. For inspecting the instrument, checking units on the basis of reference filters can easily be inserted. Operation is done intuitive using the intelligent control system SICON via touch screen technology and colour display. Values, graphs, alarm and status messages can be presented. An internal data logger allows recalling and displaying measured data from the last 32 days. A variety of analogue and digital interfaces allows smooth system integration and control.





  • Color/absorption measurement in liquids

  • Concentration measurement of substances by absorption at characteristic wavelengths.

  • Calibration in E/m, APHA-Hazen, EBC, ASTM, Saybolt, etc.

  • Dual-beam measurement for high stability.







  • Installation on standard Varivent housing or custom-specific flow cells

  • Fast and simple verification with control unit.

  • Option: Turbidity compensation using a second wavelength.





SPECIFICATIONS




  • Measuring principle : Absorption

  • Nominal range: 0 . 3 E

  • Scale ranges: 8 ranges, freely configurable

  • Resolution: 0.001 E

  • Flow cell material: Stainless steel 316L, Titanium, Hastelloy, PVDF, etc.







  • Ambient temperature: -20 . +50 C

  • Flow cells: Varivent, custom-specific

  • Wavelengths UV: 254, 313, 365, 436, 546 nm

  • Wavelengths VIS: 365, 380 . 700 nm

  • Units: E, E/m, APHA-Hazen, EBC, Saybolt, ASTM, GOST, etc.



View Complete Details

TurbiGuard

The TurbiGuard monitors medium to high turbidity, in process liquids using transmitted light (880 nm). A single version of the TurbiGuard featuring two measuring ranges can be widely used for monitoring medium to high turbidity. The TurbiGuard is factory calibrated with a true, linearized Formazine calibration. For simple applications and system integration the instrument configuration and communication can be easily done using the serial interface in combination with the existing outputs. For a more comfortable installation and operation the optional control unit SICON with touch screen technology and colour display can be connected.


APPLICATION

Applications include SEPARATORS/CENTRIFUGES in Breweries & Beverages, Foods & Dairy, Pharmaceuticals & Chemicals





  • Seal less design

  • Extremely low maintenance

  • Wide nominal range

  • Linearized factory calibration over the whole nominal range

  • Easy configuration and system integration






For simple applications and system integration the instrument configuration can be easily done using the serial interface.


For a more comfortable installation and operation the optional control unit SICON with touch screen technology and colour display can be connected.





SPECIFICATIONS




  • Wavelength: LED 880 nm

  • Measuring principle: Absorption

  • Scale ranges:
    0 . 100 / 0 . 1, 000 EBC
    0 . 400 / 0 . 4, 000 NTU

  • Resolution: 0.5 EBC / 2 NTU

  • Installation: In-line housing Varivent or compatible

  • Protection: IP66

  • Sample temperature: -10 . +100 C







  • Outputs:
    1 x 0/4 . 20 mA
    2 x Open-Collector Transistor

  • Supply voltage: 9 . 30 VDC

  • Power input: < 2 W (with Profibus DP: < 3 W)

  • Sample pressure: 1 MPa (10 bar) @ 100 C

  • Interfaces: Profibus DP or Modbus RTU (option)

  • Ambient environment: -10 . +50 C / 0 . 100 % RH

  • Cleaning: CIP/SIP compatible up to 120 C



View Complete Details

Laboratory Turbidity Meter

The LabScat 2 monitors Turbidity in liquids, using a single light source to detect transmitted light and scattered light at 90 and 25. Sample ID and handling measuring data are performed using digital interfaces (USB, Ethernet with web browser).


APPLICATIONS


Applications include Breweries & Beverages





  • Compact design

  • High measuring span

  • Precise and reliable measurement also at 0 C / 32 F

  • Colour compensated dual-angle measurement according to EBC- / MEBAK Standard

  • Bottle rotation and water bath to minimize disturbing influences







  • Monitoring of the water bath quality

  • Integrated control panel with colour touch screen display

  • Quick adjustment with secondary standard

  • Easy maintenance, no tools required





SPECIFICATIONS





  • Measuring principle: Scattered light 90/25

  • Nominal range: 0 . 200 (500 with cuvette) EBC 0 . 13, 800 (34, 500 with cuvette) ASBC

  • Wavelength: LED 650 nm

  • Resolution: 0.001 EBC / 0.07 ASBC







  • Water bath temperature: 0 . 40 C (0 . 104 F)

  • Recalibration: Secondary solid reference

  • Power input: 10 W (max.)

  • Options : Temperature controlled measurement

  • Interfaces: Ethernet, USB



View Complete Details

Water Turbidity Meter

The AquaScat measures turbidity of potable water according to IEC 27027 using 90+ scattered light detection in a free-falling water stream (models WTM, WTM A, HT). This contactless design eliminates window foiling and minimizes servicing to a minimum. Calibration check is performed with a calibration unit that is either mounted to perform the check or that is already built in (depending on variant).


APPLICATIONS



  • Turbidity measurement in raw water

  • Monitoring of flocculation and dosage of flocculants

  • Filtration monitoring of filter performance and back-wash control

  • Turbidity measurement in treated and final waters

  • Turbidity monitoring of water in storage and distribution networks

  • Turbidity measurement in process and waste waters





    • True non-contact measurement in free-fall stream (models WTM, WTM A, HT) making it virtually maintenance free

    • Dual beam measurement in optimized cell (model P)

    • Re-calibration with secondary standard (fully automatic at model WTM A)







    • Lowest stray light levels

    • Convenient operation via touch screen

    • Graphical display of trends and/or values

    • Visualization of measured values over the previous month





    SPECIFICATIONS



    • Measuring principle:
      90 Scattered light according to
      ISO 7027/EN27027

    • Light source: LED 880 nm

    • Measuring span:
      0 . 4000 FNU (WTM, WTM A, HT)
      0 . 100 FNU (P)

    • Measuring ranges: 8, freely programmable

    • Resolution:
      0.001 FNU (WTM, WTM A, P);
      0.1 FNU (HT)







    • Sample temperature: 0 . +40 C

    • Ambient temperature: 10 . +50 C

    • Operation: Touchscreen

    • Outputs:
      2 0/4 . 20 mA, galv. isolated
      2 Relays 250 VAC, 4A

    • Inputs:
      1 for optional flow meter
      2 0/4 . 20 mA

    • Digital interfaces: Ethernet, Modbus TCP, SD-card

    • Optional: Profibus DP, Modbus RTU







View Complete Details

Nitrogen Pressure Meter

Laboratory Nitrogen Pressure Meter LAB.N2 determines non-destructively and precisely thecontainer pressure of bottled still beverages with dosed N2 in PET and glass, like juices, waters and still wines. Longterm tests on the same sample are now possible.Also, measurements on PET containers closed with sportscaps are enabled.


Disposal of sample common with invasivemanometer methods is economized.





  • No moving parts, maintenance-free

  • Extremely fast, easy handling

  • Loss-free sample treatment







  • Non-invasive, non-destructive

  • Precisepressure determination





SPECIFICATIONS




  • Measuring range: 0-3, 5 bar

  • Accuracy: +/- 0, 05 bar

  • Repeatability: +/- 0, 02 bar







  • Measuring result: within 1 minute

  • Data interface: to ACM QUATROL




View Complete Details

Carbon Dioxide Meter

Laboratory CO2-Meter LAB.CO for non-destructive, high precision dissolved CO2 content measurement in bottled beverages.


Laser technology, in combination with state-of-the-art electronics and mathematics, lead to a revolutionary new method for CO2 determination in bottled carbonated waters, lemonades, beer, cider, sparkling wines and champagne.


No piercing of package is required, therefore no change of physical system; non-invasive measurement.


Only ACMs direct CO2 content measurement in the closed bottle provides you with the very true CO2 content of your package.


ACM also has aCO2 monitor for inline / online CO2 measurement.





  • No moving parts, maintenance-free

  • Extremely fast, easy handling







  • CO2 selective measurement

  • Loss-free sample treatment





SPECIFICATIONS




  • Measuring range: 0 10 Vol. / 0 20 g/l CO2

  • Accuracy: +/- 0, 025 Vol. / 0, 05 g/l

  • Reproducability: +/- 0, 01 Vol. / 0, 02 g/l








  • Measuring time: within 1 minute

  • Data interface: to ACM process monitors incorporated



View Complete Details

TURBISCAT

The TurBiScat monitors turbidity in liquids using scattered light; optionally also the (beer) colour in EBC. The combination of Hastelloy and sapphire in a sealless design allows operating the unit in practically all process applications. Turbidity measurement is done with colour compensation. Window fouling is monitored, compensated and can be checked using an anti-fouling control. Calibration is easily done using a secondary reference standard.


APPLICATION

Applications include Breweries & Beverages, Foods & Dairy, Pharmaceuticals & Chemicals





  • Seal-less design makes it maintenance free.

  • Measuring span: 0.1000 EBC (0.4000 NTU)

  • Extended sensor check with anti-fouling control







  • 2-Angle measurement with colour compensation

  • Optional colour measurement

  • Easy adjustment with secondary standard





SPECIFICATIONS




  • Wavelength turbidity: LED 650 nm

  • Wavelength color (optional): LED 430 nm

  • Measuring principle: 90/25 scattered light measurement

  • Resolution: < 0.001 EBC of full scale

  • Repeatability: 0.001 EBC or 0.25% of full scale

  • Protection class: IP 66

  • Installation: In-line housing Varivent

  • Supply voltage: 9 . 30 VDC, 3 W (of control unit)

  • Sample temperature:
    -10 . +100 C
    120 C max. 2 h
    150 C max. 1 h
    180 C max. with cooling (optional)







  • Sample pressure:
    2 MPa (20 bar) @ 180 C
    4 MPa (40 bar) @ 100 C

  • Ambient environment:
    -10 . +50 C
    0 . 100 % relative humidity

  • Nominal range color: 0 . 50 EBC

  • Nominal range turbidity:
    0 . 1, 000 EBC
    0 . 4, 000 NTU

  • Material sensor head: Hastelloy C-22

  • Windows material: Sapphire




View Complete Details

Viscosity Meter

Karishma Instruments Pvt. Ltd - We are offering a wide range of viscosity meter from India.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Sashi Nair (Karishma Instruments Private Limited)
  • 204, A Wing, Solaris 1, Saki Vihar Road, Andheri (East), Mumbai 400 072. Maharashtra., Andheri East - 400097
  • Share us via
Retailer of Measuring Instruments & Equipment from Mumbai, Maharashtra by Karishma Instruments Private Limited
Post Buy Requirement
KI
Mumbai, Maharashtra, India
Add Review

Measuring Instruments & Equipment #414160

Visiguard Scattered Light Intensity Meter

The VisGuard measures the scattered light intensity of a sample drawn into the instrument. Filtered purge air is fed through the flow cell, thus enveloping the sample in a protective shroud of clean air. This effectively keeps the optics clean. Installations are either in the tunnel cavity/niches (in-situ) OR alternatively away from the area of measurement extracting the sample from the area through pipes via an external arrangement. An optional sample heater eliminates the influence of any mist effects.

APPLICATION

Dust concentration in air, oil mist detection in ship industry, machine & metal industry, visibility monitoring in rail and road tunnels

  • Easy to service, high sensitivity, stability and accuracy
  • Easy zero-point checking, even when visibility is poor
  • A special sample flow concept entirely eliminates the danger of flow cell contamination
  • Easy calibration check with checking rod, even at high dust levels
  • Continuous monitoring of visibility using scattered light principle
  • Dual-beam method
  • Operation via local control unit or central multi-channel control unit
  • Installation in tunnel tube or niche
  • Optional sample heater: Choice of measurement with/without fog compensation
SPECIFICATIONS
  • Nominal range:
    0 . 100 PLA (Polystyrol-Latex-Aerosols)
    0 . 3 E/m
  • Scale ranges: 0 . 15 10-3 E/m
  • Protection: IP65
  • Sample temperature: -20 . +50 C
  • Sample pressure: max. 3000 Pa (30 mbar)
  • Interfaces:
    RS232 or Profibus DP
    0/4 . 20 mA
    relay contacts

  • Control unit
  • Ambient environment:
    Temperature range -20 . +50C
    0 . 100% r.h.
  • Maximum service altitude 3, 000 m above sea level
  • Power supply: 85 . 264 V / 47 . 440 Hz
View Complete Details

ColorPlus - Color Measuring Equipment

he ColorPlus measures the colour/absorbance online at up to three different wavelengths in the UV and visible range, also combined. Turbidity can be compensated at the same time by selecting an appropriate wavelength. The modular design of the instrument enables to cover various applications by selecting the most suitable measuring cell. In many cases, a standard housing like e.g. Varivent is used. Alternatively, custom-specific flow cells in different materials and designs are available. For inspecting the instrument, checking units on the basis of reference filters can easily be inserted. Operation is done intuitive using the intelligent control system SICON via touch screen technology and colour display. Values, graphs, alarm and status messages can be presented. An internal data logger allows recalling and displaying measured data from the last 32 days. A variety of analogue and digital interfaces allows smooth system integration and control.

  • Color/absorption measurement in liquids
  • Concentration measurement of substances by absorption at characteristic wavelengths.
  • Calibration in E/m, APHA-Hazen, EBC, ASTM, Saybolt, etc.
  • Dual-beam measurement for high stability.
  • Installation on standard Varivent housing or custom-specific flow cells
  • Fast and simple verification with control unit.
  • Option: Turbidity compensation using a second wavelength.
SPECIFICATIONS
  • Measuring principle : Absorption
  • Nominal range: 0 . 3 E
  • Scale ranges: 8 ranges, freely configurable
  • Resolution: 0.001 E
  • Flow cell material: Stainless steel 316L, Titanium, Hastelloy, PVDF, etc.
  • Ambient temperature: -20 . +50 C
  • Flow cells: Varivent, custom-specific
  • Wavelengths UV: 254, 313, 365, 436, 546 nm
  • Wavelengths VIS: 365, 380 . 700 nm
  • Units: E, E/m, APHA-Hazen, EBC, Saybolt, ASTM, GOST, etc.
View Complete Details

TurbiGuard

The TurbiGuard monitors medium to high turbidity, in process liquids using transmitted light (880 nm). A single version of the TurbiGuard featuring two measuring ranges can be widely used for monitoring medium to high turbidity. The TurbiGuard is factory calibrated with a true, linearized Formazine calibration. For simple applications and system integration the instrument configuration and communication can be easily done using the serial interface in combination with the existing outputs. For a more comfortable installation and operation the optional control unit SICON with touch screen technology and colour display can be connected.

APPLICATION

Applications include SEPARATORS/CENTRIFUGES in Breweries & Beverages, Foods & Dairy, Pharmaceuticals & Chemicals

  • Seal less design
  • Extremely low maintenance
  • Wide nominal range
  • Linearized factory calibration over the whole nominal range
  • Easy configuration and system integration

For simple applications and system integration the instrument configuration can be easily done using the serial interface.

For a more comfortable installation and operation the optional control unit SICON with touch screen technology and colour display can be connected.

SPECIFICATIONS
  • Wavelength: LED 880 nm
  • Measuring principle: Absorption
  • Scale ranges:
    0 . 100 / 0 . 1, 000 EBC
    0 . 400 / 0 . 4, 000 NTU
  • Resolution: 0.5 EBC / 2 NTU
  • Installation: In-line housing Varivent or compatible
  • Protection: IP66
  • Sample temperature: -10 . +100 C
  • Outputs:
    1 x 0/4 . 20 mA
    2 x Open-Collector Transistor
  • Supply voltage: 9 . 30 VDC
  • Power input: < 2 W (with Profibus DP: < 3 W)
  • Sample pressure: 1 MPa (10 bar) @ 100 C
  • Interfaces: Profibus DP or Modbus RTU (option)
  • Ambient environment: -10 . +50 C / 0 . 100 % RH
  • Cleaning: CIP/SIP compatible up to 120 C
View Complete Details

Laboratory Turbidity Meter

The LabScat 2 monitors Turbidity in liquids, using a single light source to detect transmitted light and scattered light at 90 and 25. Sample ID and handling measuring data are performed using digital interfaces (USB, Ethernet with web browser).

APPLICATIONS

Applications include Breweries & Beverages

  • Compact design
  • High measuring span
  • Precise and reliable measurement also at 0 C / 32 F
  • Colour compensated dual-angle measurement according to EBC- / MEBAK Standard
  • Bottle rotation and water bath to minimize disturbing influences
  • Monitoring of the water bath quality
  • Integrated control panel with colour touch screen display
  • Quick adjustment with secondary standard
  • Easy maintenance, no tools required

SPECIFICATIONS

  • Measuring principle: Scattered light 90/25
  • Nominal range: 0 . 200 (500 with cuvette) EBC 0 . 13, 800 (34, 500 with cuvette) ASBC
  • Wavelength: LED 650 nm
  • Resolution: 0.001 EBC / 0.07 ASBC
  • Water bath temperature: 0 . 40 C (0 . 104 F)
  • Recalibration: Secondary solid reference
  • Power input: 10 W (max.)
  • Options : Temperature controlled measurement
  • Interfaces: Ethernet, USB
View Complete Details

Water Turbidity Meter

The AquaScat measures turbidity of potable water according to IEC 27027 using 90+ scattered light detection in a free-falling water stream (models WTM, WTM A, HT). This contactless design eliminates window foiling and minimizes servicing to a minimum. Calibration check is performed with a calibration unit that is either mounted to perform the check or that is already built in (depending on variant).

APPLICATIONS

  • Turbidity measurement in raw water
  • Monitoring of flocculation and dosage of flocculants
  • Filtration monitoring of filter performance and back-wash control
  • Turbidity measurement in treated and final waters
  • Turbidity monitoring of water in storage and distribution networks
  • Turbidity measurement in process and waste waters
    • True non-contact measurement in free-fall stream (models WTM, WTM A, HT) making it virtually maintenance free
    • Dual beam measurement in optimized cell (model P)
    • Re-calibration with secondary standard (fully automatic at model WTM A)
    • Lowest stray light levels
    • Convenient operation via touch screen
    • Graphical display of trends and/or values
    • Visualization of measured values over the previous month
    SPECIFICATIONS
    • Measuring principle:
      90 Scattered light according to
      ISO 7027/EN27027
    • Light source: LED 880 nm
    • Measuring span:
      0 . 4000 FNU (WTM, WTM A, HT)
      0 . 100 FNU (P)
    • Measuring ranges: 8, freely programmable
    • Resolution:
      0.001 FNU (WTM, WTM A, P);
      0.1 FNU (HT)
    • Sample temperature: 0 . +40 C
    • Ambient temperature: 10 . +50 C
    • Operation: Touchscreen
    • Outputs:
      2 0/4 . 20 mA, galv. isolated
      2 Relays 250 VAC, 4A
    • Inputs:
      1 for optional flow meter
      2 0/4 . 20 mA
    • Digital interfaces: Ethernet, Modbus TCP, SD-card
    • Optional: Profibus DP, Modbus RTU
View Complete Details

Nitrogen Pressure Meter

Laboratory Nitrogen Pressure Meter LAB.N2 determines non-destructively and precisely thecontainer pressure of bottled still beverages with dosed N2 in PET and glass, like juices, waters and still wines. Longterm tests on the same sample are now possible.Also, measurements on PET containers closed with sportscaps are enabled.

Disposal of sample common with invasivemanometer methods is economized.

  • No moving parts, maintenance-free
  • Extremely fast, easy handling
  • Loss-free sample treatment
  • Non-invasive, non-destructive
  • Precisepressure determination
SPECIFICATIONS
  • Measuring range: 0-3, 5 bar
  • Accuracy: +/- 0, 05 bar
  • Repeatability: +/- 0, 02 bar
  • Measuring result: within 1 minute
  • Data interface: to ACM QUATROL
View Complete Details

Carbon Dioxide Meter

Laboratory CO2-Meter LAB.CO for non-destructive, high precision dissolved CO2 content measurement in bottled beverages.

Laser technology, in combination with state-of-the-art electronics and mathematics, lead to a revolutionary new method for CO2 determination in bottled carbonated waters, lemonades, beer, cider, sparkling wines and champagne.

No piercing of package is required, therefore no change of physical system; non-invasive measurement.

Only ACMs direct CO2 content measurement in the closed bottle provides you with the very true CO2 content of your package.

ACM also has aCO2 monitor for inline / online CO2 measurement.

  • No moving parts, maintenance-free
  • Extremely fast, easy handling
  • CO2 selective measurement
  • Loss-free sample treatment
SPECIFICATIONS
  • Measuring range: 0 10 Vol. / 0 20 g/l CO2
  • Accuracy: +/- 0, 025 Vol. / 0, 05 g/l
  • Reproducability: +/- 0, 01 Vol. / 0, 02 g/l

  • Measuring time: within 1 minute
  • Data interface: to ACM process monitors incorporated
View Complete Details

TURBISCAT

The TurBiScat monitors turbidity in liquids using scattered light; optionally also the (beer) colour in EBC. The combination of Hastelloy and sapphire in a sealless design allows operating the unit in practically all process applications. Turbidity measurement is done with colour compensation. Window fouling is monitored, compensated and can be checked using an anti-fouling control. Calibration is easily done using a secondary reference standard.

APPLICATION

Applications include Breweries & Beverages, Foods & Dairy, Pharmaceuticals & Chemicals

  • Seal-less design makes it maintenance free.
  • Measuring span: 0.1000 EBC (0.4000 NTU)
  • Extended sensor check with anti-fouling control
  • 2-Angle measurement with colour compensation
  • Optional colour measurement
  • Easy adjustment with secondary standard
SPECIFICATIONS
  • Wavelength turbidity: LED 650 nm
  • Wavelength color (optional): LED 430 nm
  • Measuring principle: 90/25 scattered light measurement
  • Resolution: < 0.001 EBC of full scale
  • Repeatability: 0.001 EBC or 0.25% of full scale
  • Protection class: IP 66
  • Installation: In-line housing Varivent
  • Supply voltage: 9 . 30 VDC, 3 W (of control unit)
  • Sample temperature:
    -10 . +100 C
    120 C max. 2 h
    150 C max. 1 h
    180 C max. with cooling (optional)
  • Sample pressure:
    2 MPa (20 bar) @ 180 C
    4 MPa (40 bar) @ 100 C
  • Ambient environment:
    -10 . +50 C
    0 . 100 % relative humidity
  • Nominal range color: 0 . 50 EBC
  • Nominal range turbidity:
    0 . 1, 000 EBC
    0 . 4, 000 NTU
  • Material sensor head: Hastelloy C-22
  • Windows material: Sapphire
View Complete Details

Viscosity Meter

Karishma Instruments Pvt. Ltd - We are offering a wide range of viscosity meter from India.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Sashi Nair (Karishma Instruments Private Limited)
  • 204, A Wing, Solaris 1, Saki Vihar Road, Andheri (East), Mumbai 400 072. Maharashtra., Andheri East - 400097
  • Share us via