House Wires

We are among the renowned Housing Wires Manufacturers in India. We serve high quality House Wires broadly applied for installation in surface mounted or embedded conduits. Our House Wiring Cable is made up of high quality raw materials.

Features
  • Consistent Impedance
  • Consistent Capacitance
  • Consistent Impedance
  • Cross talk
  • Attenuation
ApplicationsInstallation in surface mounted or embedded conduits or similar closed systems. Indoors, building wires, power cord and domestic electrical wiring purpose QualityStringent checks at every stage to ensure that material, machines and men work in perfect harmony to produce a product of envious quality. Design & TechnologyOn line annealed fine wires bunched to a smooth finish with uniform lay. Extrusion with self-centering devices coupled with on line diameter controller to ensure the insulation fits the conductor perfectly eliminating any risk of weak spot. A double layered PVC insulation outlined with an extruded thin colour film to ensure the insulation remains strong through out the life of the wire.

House Wires

Single Core Pvc Insulated Copper Conductor (Unsheathed) House Wires in Voiltage Grade Upto & Including 1100 V (IS : 694 : 1990)
Nominal Cross Section Area of Conductor mm2Number/Nom. Dia. of wires (nom.) No./mmThickness of Insulation (Nom.) mmOverall Diameter Max. (mm)Current carrying capacity AmpsResistance (Max.) per Km. at 20 ' C Ohms
1 14/0.3 0.7 3.2 11 18.1
1.5 22/0.3 0.7 3.4 13 12.1
2.5 36/0.3 0.8 4.2 18 7.41
4 56/0.3 0.8 4.8 24 4.95
6 84/0.3 0.8 5.6 31 3.3
Note : Supplied in 100 meters length; packing as required.

Single Core Flexibles

Single Core Pvc Insulated Copper Conductor (Unsheathed) House Wires in Voiltage Grade Upto & Including 1100 V (IS : 694 : 1990)
Nominal Cross Section Area of Conductor mm2Number/Nom. Dia. of wires (nom.) No./mmThickness of Insulation (Nom.) mmOverall Diameter Max. (mm)Current carrying capacity AmpsResistance (Max.) per Km. at 20 ' C Ohms
10 141/0.3 1 8 51 1.91
16 126/0.4 1 9.6 68 1.21
25 196/0.4 1.2 11.5 86 0.78
35 276/0.4 1.2 13 110 0.55
50 396/0.4 1.4 15 145 0.39

Multi Core Flexibles

Multicore Circular PVC Insulated Copper Conductor and Sheathed Cables in Voiltage Grade upto & Including 1100 V (IS : 694 : 1990)
Nominal Cross Section Area of Conductormm2 Number/Nom. Dia. of wires No./mm Thickness of Insulation (Nom.) mm Thickness of Sheath (Nom.) 2core, 3core, 4core Overall Diameter Max. (mm) Current carrying capacity Resistance (Max.) per Km. at 20 ' C Ohms
mmmmmm2core3core4core
0.5 16/02 0.6 0.9 0.9 0.9 7.2 7.6 8.2 4 39
0.75 24/0.2 0.6 0.9 0.9 0.9 7.8 8.2 8.8 7 26
1 32/0.2 0.6 0.9 0.9 0.9 8 8.6 9.4 11 19.5
1.5 48/0.2 0.6 0.9 0.9 1 8.6 9.2 10.5 15 13.3
2.5 80/0.2 0.7 1 1 1 10.5 11 12 20 7.98
4 56/0.3 0.8 1 1 1 12 12.5 14 26 4.95
  • * Sizes upto 120 sq mm
  • Note : Supplied in 100 meters length; packing as required
Sheath :
Tough outer sheath of PVC compound abrasion resistant, impervious to water, oil & grease thereby giving long life and electrical safety.
The use of flat cable often eliminates much of the conventional round wire weight and bulk. The copper cross-section can thus be reduced to that required to carry the current load or to satisfy voltage drop requirements. Flat cable is extremely flexible when bent in the plane of its thin cross-section. Because the conductor spacing is fixed and the geometry of the cable is constant, the electrical characteristics, such as impedance, capacitance, inductance, time delay, cross talk and attenuation are consistent.

Motor HP Vs Current

The full kload current for submersible pump motors, 3phase, 50 Cycles, 415 V.
H.P 5 7.5 10 12.5 15 17.5 20 25 30 35
Amp 7.5 11 14.9 18.9 22.5 25.2 28.4 35.6 42.3 50.4

Dearting Factors in Ground

Multiply the current capacity of the cable by factors given below for various ground temperatures.
Ambient Temperature (Deg. C)3035404550
Derating Factor1.091.0410.950.77

Three-core Flat Submersible Cables in Voiltage Grade upto & Including 1100 V (IS : 694 : 1990)

Area (Nom.) Sq. mmNumber/size of WireInsulation Thickness (Nom.) mmSheath Thickness (Nom.) mmWidth 'W' (Approx) mmThickness 'T' (Approx) mmResistance at 20C (Max.) ohm/KmCurrent carrying capacity at 40C Amps
1.5 22/0.3 0.6 0.9 11 5 12.1 14
2.5 36/0.3 0.7 1 13 6 7.4 18
4 56/0.3 0.8 1 15.3 6.7 4.95 26
6 84.0.3 1 1.15 18.7 7.9 3.3 31
10 140/0.3 1 1.4 23.7 9.9 1.91 42
16 226/0.3 1 1.4 28 11.4 1.21 57
25 354/0.3 1.2 2 35.5 14.7 0.78 72
35 495/0.3 1.2 2 39.5 16.2 0.55 90
50 703/0.3 1.4 2.2 45.5 18.3 0.39 115
70 360/0.5 1.4 2.2 51 20 0.27 143
95 475/0.5 1.6 2.4 60 23.5 0.21 165