Our Products
Technical Specifications
Input Mode | |
Voltage | 170-280 V |
Tolerance | ± 5 V |
Frequency | 50 Hz ± 10% (10 Hz Window) |
Phase | Single Phase |
Input Power Factor | Uncontrolled |
Output Mode | |
Voltage | 230V ± 1% |
Frequency | 50 Hz ± 0.5 Hz |
Crest Factor | 4 : 1 |
Output Power Factor | 0.8 |
Harmonic Distortion | < 3 % |
Output Wave Form | Pure Sine Wave |
Transit Response | 5% Recovery within 1. 5 Cycle (For 100% Dynamic Loading) |
Overall Efficiency (at 100% Load) | > 87 % |
Output Voltage Low Protection | 180 V (22% below nominal Voltage) |
Output Voltage High Protection | 253 V (10% above nominal Voltage) |
Output Shortage Circuit Protection | Load > 300 % |
Overload Capacity | 110% for 5 minutes 150% for 10 seconds 200% for 2 seconds 300% for 1 seconds |
Transfer Time | |
AC To DC | Zero |
Battery Parameters | |
Battery Voltage (Nominal) | 180 V |
Number of Batteries | 15 |
Battery Size | 12 V (12AH to 80AH) |
Battery Type | Lead Acid Battery / SMF Battery |
Battery Charging Current | 0.8A ± 0.2A to 8.0A ± 0.5A |
Battery Low Alarm | 165 V ± 1 V |
Battery Low Protection | 162 V ± 1 V |
Battery High Protection | 225 V ± 1 V |
Battery Charger Cut Level | 198 V ± 1 V |
Display | |
Mains Voltage | Low Battery Voltage Alarm |
Mains Frequency | Short Cut Protection |
Output Voltage | Low Battery Cut Off |
Output Load % | Output Frequency |
Battery Voltage | Over Load Protection |
The Technical specifications are subjected to change without prior notice for the further Improvement in products. |
Specifications
Output Power | 3.0KVA/48V | 5.0KVA/120V | 10.0KVA/180V | Above then 10KVA |
---|---|---|---|---|
Output Voltage at No Load | 220 V ± 7V | 220 V ± 7V | 220 V ± 7V | 220 V ± 7V |
Output Voltage Regulation in mains mode | Only 12% | Only 12% | Only 12% | Only 12% |
Output Frequency | 50Hz ± 0.5Hz | 50Hz ± 0.5Hz | 50Hz ± 0.5Hz | 50Hz ± 0.5Hz |
Low Battery Cut - Off | 40V ± 0.8V | 100V ± 2V | 150V ± 3V | 10.0V ± 0.2 per Battery ( Depending on DC Bus Voltage) |
Input Voltage Range | 100V 280V | 100V 280V | 100V 280V | 100V 280V |
Charging Current | 10A ± 1A | 10A ± 1A | 10A ± 1A | 10A ± 1A |
Boost Charging Voltage | 57.6V ± 0.8V | 144V ± 2V | 216.0V ± 3V | 14.4V ± 0.2 per Battery ( Depending on DC Bus Voltage) |
Trigger Charging Voltage | 54.4V ± 0.8V | 136V ± 2V | 204.0V ± 3V | 13.6V ± 0.2 per Battery ( Depending on DC Bus Voltage) |
Change Over Time UPS Mode | Less then 10mSec | Less then 10mSec | Less then 10mSec | Less then 10mSec |
Change Over Time Inverter Mode | Less then 50mSec | Less then 50mSec | Less then 50mSec | Less then 50mSec |
Efficiency | 85% | 85% | 85% | 85% |
Surge Current Capacity | UpTo 300% | UpTo 300% | UpTo 300% | UpTo 300% |
Dimensions w/o packing | 350 x 300 x 280 mm | 300 x 350 x 540 mm | 350 x 400 x 660 | Depending on Capacity |
Dimensions with Packaging | 470 x 420 x 370 mm | 425 x 475 x 620 mm | 475 x 525 x 720 mm | Depending on Capacity |
Weight | 34.5 Kg | 50 kg | 90 kg | Depending on Capacity |
Protections | Thermal Shutdown, Short Circuit Shut Down, Overload Shut Down with 6 Retry, Battery High Cut | Thermal Shutdown, Short Circuit Shut Down, Overload Shut Down with 6 Retry, Battery High Cut | Thermal Shutdown, Short Circuit Shut Down, Overload Shut Down with 6 Retry, Battery High Cut | Thermal Shutdown, Short Circuit Shut Down, Overload Shut Down with 6 Retry, Battery High Cut |
LCD Panel Display | Battery Level & Load Levels with Bar Graph All Protections Output & AC Mains voltage and Frequency Battery charging/Charged & Battery voltage Switch States & Capacity | Battery Level & Load Levels with Bar Graph All Protections Output & AC Mains voltage and Frequency Battery charging/Charged & Battery voltage Switch States & Capacity | Battery Level & Load Levels with Bar Graph All Protections Output & AC Mains voltage and Frequency Battery charging/Charged & Battery voltage Switch States & Capacity | Battery Level & Load Levels with Bar Graph All Protections Output & AC Mains voltage and Frequency Battery charging/Charged & Battery voltage Switch States & Capacity |