Post Buy Requirement
KE
Bangalore, Karnataka, India
Add Review

Our Products

  1. UPS 3 Products available
  2. Circuit Breaker 6 Products available
  3. Industrial Motors 4 Products available
  4. Transformers 21 Products available
  5. AC Motor 7 Products available
  6. Electric Fittings And Components 3 Products available
  7. Electric Motors & Components 10 Products available
  8. Generators 16 Products available
  9. Others 35 Products available

Circuit Breaker #2189817

Vacuum Circuit Breaker

Features
  • Maintenance free design
  • Horizontal drawout and isolation
  • Positive racking mechanism
  • Interlocks to prevent insertion/withdrawal of closed CB
  • CB can operate in test or service position only
  • Identically rated CBs are fully interchangable
  • Easy retro fitting with cassette system
  • Fully type tested as per IEC60056/IS 13118/IEC 62271-100

 

Operating Mechanism
  • Proven spring operated mechanism
  • Designed to closed and latch
  • Positive racking mechanism
  • Manual/motorised option
  • In built trip free mechanism
  • In built anti pumping feature
  • Mechanical ON/OFF indication

 

 

    VCB C500 VRK 12-4 VRK 24 VRK 36
Rated Voltage kV 12 12 24 36
Insulation level kVrms/kVp 28/75 28/75 50/125 70/170
Rated Current A 1250 2500 1600 1600
Braking Capacity kA 26.2 40 40 26.2
Making Capacity kAp 65.5 100 100 78.75
Short Time Current
(1 or 3 Sec)
kA 26.2 40 40 26.2
Operating Sequence   O - 0.3 Sec - CO - 3 min - CO
Auxiliary Switch Contacts   8NO + 8NC
Spring Charging Motor Power W 250
Spring Charging Motor Voltage V 230V AC, 110V DC, 220V DC
Closing / Tripping Coil Power W 180
Closing / Tripping Coil Voltage V 24, 30, 48, 110, 220DC
Weight (approx) kG 150 140 140 360

View Complete Details

Vacuum Circuit Breakers

Maintenance free design, Horizontal drawout and isolation, Positive racking mechanism, Interlocks to prevent insertionwithdrawal of closed CB, CB can operate in test or service position only, Fully type tested as per IEC60056IS 13118IEC 62271-100, Easy retro fitting with cassette system, Spring Charging Motor Voltage:230V AC, 110V DC, 220V DC.
View Complete Details

Electrical Circuit Breaker

Even in the event of a complete gas leak, our SF6 CBs are capable of breaking 100% normal current & with stand system voltage. Our SF6 CBs operate at low pressure. The internal pressure rise at the instant of current interruption also stays low. Due to this, and the high degree of gas tightness, adequate for entire life of the breaker is ensured.No degradation of main current carrying contacts, as there are separate currents carrying and arcing contacts. Weight (approx) :200, 225, kG.
View Complete Details

Circuit Breaker

Features
  • Even in the event of a complete gas leak, our SF6 CBs are capable of breaking 100% normal current & with stand system voltage
  • Advance warning of gas leak by continuous pressure monitoring
  • Explosion proof and fail-safe CB by means of safety membrane for each pole
  • Automatic safety shutters to cover live parts when CB is withdrawn
  • No degradation of main current carrying contacts, as there are separate currents carrying and arcing contacts
  • Our SF6 CBs operate at low pressure. The internal pressure rise at the instant of current interruption also stays low. Due to this, and the high degree of gas tightness, adequate for entire life of the breaker is ensured.

Operating Mechanism
  • Proven spring operated mechanism
  • Designed to closed and latch
  • Manual/motorised option
  • In built trip free mechanism
  • In built anti pumping feature
  • Mechanical ON/OFF indication

    FP62D FP63G FP62D FP63G FP72D FP73D
Rated Voltage kV 12 12 24 24 36 36
Insulation level kVrms / kVp 28 / 75 28 / 75 50 / 125 50 / 125 70 / 170 70 / 170
Rated Current A 1250 2500 1250 2500 1600 1600
Braking Capacity kA 26.2 40 26.2 26.2 16 26.2
Making Capacity kAp 65.5 100 65.5 65.5 40 65.5
Short Time Current (1 or 3 Sec) kA 26.2 40 26.2 26.2 16 26.2
Operating Sequence   O - 0.3 Sec - CO - 3 min - CO
Auxiliary Switch Contacts   8NO + 8NC
Spring Charging Motor Power W 250
Spring Charging Motor Voltage V 230V AC, 110V DC, 220V DC
Closing / Tripping Coil Power W 80
Closing / Tripping Coil Voltage V 24, 30, 48, 110, 220DC
View Complete Details

Porcelain Clad Vaccum Circuit Breaker

Features
  • Suitable for auto-reclosure duty
  • Fully type tested
  • High electrical and mechanical life
  • Low contact resistance
  • Suitable for capacitive current switching
  • High reliability due to simple linkages
  • Low maintenance
  • Long life - more than 100 short circuit operations

Rated Voltage kV 36
Insulation level kVrms / kVp 70/170
Rated Current A 1600
Braking Capacity kA 26.2
Making Capacity kAp 65.5
Short Time Current (1 or 3 Sec) kA 26.2
Operating Sequence   O - 0.3 Sec - CO - 3 min - CO
Auxiliary Switch Contacts   8NO + 8NC
Spring Charging Motor Power W 250
Spring Charging Motor Voltage V 230V AC, 110V DC, 220V DC
Closing / Tripping Coil Power W 180
Closing / Tripping Coil Voltage V 24, 30, 48, 110, 220DC
Opening time ms <50
Closing time ms <100
Weight kGS 650
View Complete Details

SF6 Circuit Breaker

We offer sf6 circuit breaker. Fp62dfp63gfp62dfp63gfp72dfp73drated voltage kv121224243636insulation level kvrms kvp28 7528 7550 12550 12570 17070 170rated current a125025001250250016001600braking capacity ka26.24026.226.21626.2making capacity kap65.510065.565.54065.5short time current (1 or 3 sec) ka26.24026.226.21626.2operating sequence o - 0.3 sec - co - 3 min - coauxiliary switch contacts 8no + 8ncspring charging motor power w250spring charging motor voltage v230v ac, 110v dc, 220v dcclosing tripping coil power w80closing tripping coil voltage v24, 30, 48, 110, 220dcweight (approx) kg200225200225 225 250.
View Complete Details