The special unique Krew Instruments Pvt Ltd design of the cushioned couch assist in reducing all chances of any vasovagal attack. For instance, a vasovagal attack does occur, then the donor’s current position can be prompt be changed from any position just by a switch. The trays are also used for placing all the Blood Collection Monitor, and BP apparatus along with other accessories. Krew Instruments Pvt Ltd simple and easy mechanism allows a shift in trays from a left-hand position to a right-hand position or even vice-versa accurately depending upon the requirement. We have an interface to BCM that is provided, so removing the requirement for any separate power source.
Technical Specification
Catalogue No. | KDC-1 |
---|---|
Power Supply | 230 VAC |
Weight | 60 kg |
Lifting Capacity | 150 kg |
Control | Remote |
Power Consumption | 100 W |
Movement Actuation | PM DC Motor |
Length of Seat | 100 cm |
Width | 67 cm |
Length of arm rest | 60 cm |
Width of arm rest | 15 cm |
Upholstery | - |
salient features :
.
Technical Data
Model | KOS-1 | KOS-2 | KOS-3 | KOS-4 | KOS(2T)-1 |
---|---|---|---|---|---|
Platform Size | 350x350 | 700x700 | 900x900 | 1280x1280 | 600x600x2Nos |
Motor | 50 to 250 RPM (Stepper or PDMC) | 50 to 250 RPM (AC 3Ph.) | 50 to 250 RPM (AC 3Ph.) | 50 to 200 RPM (AC 3Ph.) | 50 to 200 RPM (AC 3Ph.) |
Flask Capacity | 9 Nos of 250ml | 25x1000ml or 36x500ml or 36x250ml or 47x100ml | 49x1000ml or 64x500ml or 64x250ml or 100x100ml | 81x1000ml or 100x500ml or 121x250ml or 190x100ml | 25x1000mlx2nos or 36x500mlx2nos or 36x250mlx2nos or 47x100mlx2nos |
Salient Features
Technical Specification
Catalogue No. | KDC - 3 |
---|---|
Power Supply | 230 VAC |
Weight | 60 kg |
Lifting Capacity | 150 kg |
Control | Remote |
Power Consumption | 100 W |
Movement Actuation | PM DC Motor |
Length of Seat | 100 cm |
Width | 67 cm |
Length of arm rest | 60 cm |
Width of arm rest | 15 cm |
Upholstery | Soft upholstery of 2.5 thick |
The Platelet Agitator features the uniquely designed rack with high ventilation capability to allow oxygen flow to the platelets. Smooth sliding stainless steel trays are provided which can be removed for cleaning as well as forplacing of the bags. Fixed speed agitation with heavy duty bearings and quiet operation also marked as special aspects in the design. The agitation stops automatically when the door is opened.
Technical Specification
Model No. | KPA - 36 | KPA - 48 |
---|---|---|
Capacity | 36 bags | 48 bags |
Oscillation (stroke) | 70/Stroke Per Minute | 70/Stroke Per Minute |
Power Supply | 230 VAC 50 Hz | 230 VAC 50 Hz |
Accuracy | ± 5 Stroke | ± 5 Stroke |
Alarm | Motion Failure | Motion Failure |
Krew Instruments Pvt Ltd Special Features
Technical Data
Cat. No | KCM | KCM-B |
---|---|---|
Readability | 1 ml / 1g | 1 ml / 1g |
Display | Large LCD | Large VFT |
Alarm | Audio-Visual | Audio-Visual |
Input Voltage | 230V AC(SMPS). | 90-270V AC (SMPS) |
Battery Backup | -------- | 6 to 8Hrs |
Calibration | Automatic | Automatic |
Calibration
The equipment can be calibrated with the help of a master calibrator, which is stringently certified for its accuracy by the Electronics Regional Testing Laboratory (ERTL West) Government of India a reputed and recognized testing laboratory with traceable reference to the National Physical Laboratories (NPL).
Special Features
Krew Instruments Pvt Ltds Speciality’s Blood/Component Weighing Scale is installed with a built-in interface to help integrate an Electronic Plasma Expressor. When the programmed weight or its volume is attained then the clamp becomes activated and assist in stopping the process of any component transfer into the satellite bag.
Technical Specification
Catalogue. No. | KBS |
---|---|
Input Voltage | 230 VAC |
Power Supply | SMPS |
Transducer | Loadcell |
Weighing Range | 1 kg |
Accuracy | 1gm. / 1ml |
Calibration | Auto |
Display | LCD |
Weight | 1.5 kg |
Interface | --------- |
Salient Features :
Technical Data
Model | KOS-1 | KOS-2 | KOS-3 | KOS-4 | KOS(2T)-1 |
---|---|---|---|---|---|
Platform Size | 350x350 | 700x700 | 900x900 | 1280x1280 | 600x600x2Nos |
Motor | 50 to 250 RPM (Stepper or PDMC) | 50 to 250 RPM (AC 3Ph.) | 50 to 250 RPM (AC 3Ph.) | 50 to 200 RPM (AC 3Ph.) | 50 to 200 RPM (AC 3Ph.) |
Flask Capacity | 9 Nos of 250ml | 25x1000ml or 36x500ml or 36x250ml or 47x100ml | 49x1000ml or 64x500ml or 64x250ml or 100x100ml | 81x1000ml or 100x500ml or 121x250ml or 190x100ml | 25x1000mlx2nos or 36x500mlx2nos or 36x250mlx2nos or 47x100mlx2nos |
Our Special Features :
Cabinet Construction and Refrigeration System
The chamber cabinet comes insulated with an optimized high-density CFC free Poly Urethane Foam. The interior of the chamber is made with mirror finish surface of stainless Steel (304 SS, 0.8 mm thick) and the exterior with white powder coated (1.0 mm thick) mild steel. The door has a systematic magnetic door gasket with a single keyed door lock. The stainless steel trays are provided for storage inside. The perfect cooling is achieved by a hermetically sealed compressor unit of premium quality. Complete stainless steel GMP models (Inside SS 316 with mirror finished and outside. SS 304) is also manufactured by us.
Our Bio safety Cabinets are designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertrical laminar airflow to create a work area free of airborne particles and micro organisms and also to prevent these particles from flowing into the operator. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaustive HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter.
Biosafety Cabinets are classified into three categories : Class I, Class II, Class III.
There are four types of Class II cabinets
Technical Data
Name of the Equipment | Bio Safety Cabinet Class II Type A2 | |||
---|---|---|---|---|
Model | MFI BSC 2X2 | MFI BSC 3X2 | MFI BSC 4X2 | MFI BSC 6X2 |
External Dimensions (LXWXH) in Inches & MM | 29.5" x 38.9" x 83.2" 750 x 990 x 2115 | 41.3"x 38.9" x 83.2” 1050 x 990 x 2115 | 53.3"x 38.9" x 83.2" 1355 x 990 x 2115 | 77.3" x 38.9" x 83.2' 1965 x 990 x 2115 |
Work Area Dimensions (LXWXH) in Inches & MM | 26.3" x 25.5"x 25.9" 670 x 650 x 660 | 38" x 25.5" x 25.9" 970 x 650 x 660 | 46.4" x 25.5" x 25.9" 1180 X 650 X 660 | 46.6" x 25.5" x 25.9" 1885 x 650 x 660 |
Features
Internal Work Area | Stainless Steel 304 with rounded joint less corners. |
---|---|
Material of Construction | Galvanized Iron Sheet with Epoxy Polyester Thermosetting Powder Coating of 60-80 microns, 1.5 mm Thickness I Stainless Steel grade 304, 1.2 mm Thickness for SS Models |
Body Finish | Glossy Off White Colour for GI Powder Coated I Matt grit finish for Stainless Steel 304 |
Table Top | 1.5 mm Stainless Steel 304 sheet1.5 mm Stainless Steel 304 sheet |
Front Door | Frameless auto Sliding Glass Door of Toughened glass 6 mm thickness |
Wheels & Leveling Lugs | PU solid wheels with plated brackets & Metallic Powder Coated Leveling Lugs for GI Model PU solid wheels with SS 304 Brackets a Solid SS 304 Leveling Lugs For S.S. Models |
Design & Classification | Class II Type A2 complaint and approximately 30% of the air volume exhausted as sterile air back into the environment and approximately 70%of the air is re-circulated inside the work area |
Cleanliness Class | ISO Standard 14644 - 1 ISO Class 3ISO Standard 14644 - 1 ISO Class 3 |
Stages Of Filtration | 1) ULPA final = 0.12µ with an efficiency of 99.9995%1) ULPA final = 0.12µ with an efficiency of 99.9995% 2) ULPA Exhaust = 0.12µ with an ef ficiency of 99.9995%2) ULPA Exhaust = 0.12µ with an ef ficiency of 99.9995% (Anti-Microbial treated media) (ULPA Media :Made in Italy) |
Motor Blower Assembly | "Godrej"make variable speed motor mounted on PU coated" FRP Blowers wi th Aluminum Powder Coated Impellers |
Down Flow Velocity Inflow Velocity | 80 FPM at 4" from top of work table 100 FPM at work access opening |
Noise Level | < 60 Ob at 1 Meter from the face of the equipment |
Pressure Gauge | Dwyer (U.S.A) make Magnehelic gauge |
ULPA Filter Grill | SS 304 grill duly perforated and polished |
Technical Specification
Electrical | Switches & Speed Controller | Microprocessor Controlled Feather Touch switch panel | |||
Fluorescent lighting | 18 Watt - 2 nos | 18 Watt - 2 nos | 36 Watt - 2 nos. | 36 Watt - 2 nos. 18 Watt - 2 nos | |
Chokes for lighting | 18 watts - 3 nos | 18 watts - 3 nos | 36 Watt – 3 nos. | 36 Watt – 3 nos. 18 watts - 3 nos | |
Ultra Violet Lighting | 1.5 feet length G15T8 15 Watt ·Philips | 1.5 feet length G15T8 15 Watt ·Philips | 3 feet length G 30T8 30 Watt – Philips | 3 feet length G 30T8 30 Watt – Philips | |
Power Consumption | 230 Watts | 250 watts | 560 watts | 560 watts | |
Lighting | > than 800 lux | ||||
Power Supply | Single phase 5Amps power cord, 230V, 50Hz power supply, For Model MFI BSC 6x2 15 Amps power cord | ||||
Accessories | Gas I Vacuum Cock | Standard make - Optional | |||
Gas Burner | Standard make - Optional |
Autoclaves (steam sterilizers) are used to sterilize surgical equipment, laboratory instruments, pharmaceutical items and other materials. They can sterilize liquids, solids, hollows and instruments of various shapes and sizes. Autoclave sterilizer features specifically designed to sterilize for lab applications used in laboratory, microbiology, pharmaceutical, food and chemical industries. They are designed to provide high quality repeatable performance and documentation for laboratory applications and quality assurance processes.
Autoclaves vary in size, shape and functionality. A very basic autoclave is similar to a pressure cooker; both use the power of steam to kill bacteria, spores and germs resistant to boiling water and powerful detergents. One of the things that sets steam autoclaves apart from other sterilizers is its automatic lock feature. Since an autoclave is a sterilizer, its purpose is like sterilizers-to kill or remove all forms of life on an object's surface such as bacteria, fungi, viruses, and spores.
Autoclaves vary in size, shape and functionality. A very basic autoclave is similar to a pressure cooker; both use the power of steam to kill bacteria, spores and germs resistant to boiling water and powerful detergents. One of the things that sets steam autoclaves apart from other sterilizers is its automatic lock feature. Since an autoclave is a sterilizer, its purpose is like sterilizers-to kill or remove all forms of life on an object's surface such as bacteria, fungi, viruses, and spores.
While autoclaves solely utilize steam to disinfect, other sterilizers can use chemicals, high pressure, filtration, irritation, or a combination of these methods to eliminate living organisms. Not all sterilizers can be autoclaves sterilizers because not every device can withstand the high temperatures needed to kill every organism. If someone was to use a different type of equipment the material could melt and morph making it unusable.
An autoclave chamber sterilizes medical or laboratory instruments by heating them above the boiling point. Krew Instruments Pvt Ltds have tabletop as well as large autoclaves which can process numerous surgical instruments in a single sterilization cycle, meeting the ongoing demand for sterile equipment in operating rooms and emergency wards.
Features :
Special Features
Specification Detail
Benefits
Calibration Construction and refrigeration system
Our cabinet of Chambers comes well insulated with a high-density CFC free Poly Urethane Foam. The Interior of the chamber is well mirrored with a stainless Steel finishing (304 SS, 0.8 mm thick). The exterior of the unit is white powder coated i.e. (1.0 mm thick) of mild steel and which the door has a built in magnetic door gasket fitted with a keyed door lock. Our stainless steel trays are also fixed with storage inside.
Krew Instruments Pvt Ltd Special Features
Optional Accessories
Calibration
Calibration in this equipment is done with the help of a master calibrator, which is certified for its accuracyby the electronic Regional Testing Laboratory (ERTL), which is recognized by the Government of India.
Technical Specification
Cat. No | Capacity in Liters | Approximate No. of bags (350ml) | No. of Basket | Internal Dimensions (WXDXH)CMS | External Dimensions (WXDXH)CMS |
---|---|---|---|---|---|
KBR-10 | 90 | 50 | 2 | 40x40x60 | 59x59x100 |
KBR-11 | 285 | 200 | 4 | 60x60x85 | 79x78x142 |
KBR-12 | 90 | 50 | 2 | 40x40x60 | 59x59x100 |
KBR-13 | 350 | 250 | 4 | 63x65x90 | 82x81x146 |
KBR-14 | 450 | 325 | 5 | 70x70x95 | 84x88x150 |
KBR-15 | 600 | 400 | 5 | 75x75x110 | 99x93x157 |
Our Blood Bag Tube Sealers are designed to meet high standards of blood safety. Since the chemical properties of blood require a complete sterilized ambiance that helps keep the blood as pure and no contaminants as required. The equipment ensures quality sealing with a very crystal clear rupture line in order for the user to easily tear it apart segments.
Core Benefits Include :
Technical Data
Tube Sealer Model | KTS-1 | KTS-2 | KTS-3 |
---|---|---|---|
Oscillation Frequency | 40.68 MHz | $40.68 MHZ | 40.68MHZ |
Radio Frequency Output | 15W | 15W | 1W |
Sealing Time (Approx) | 1.4 Sec | 1.4 Sec | 1.4Sec |
Input Voltage | 230 V AC | 230 V AC | 230 V AC |
Frequency | 50Hz | 50Hz | 50Hz |
Power Consumption | 80 V A | 80 V A | 80 V A |
Weight Approx | 4 Kgs | 5 Kgs | 2.5 Kgs |
Battery Back-up | NA | 350 seals | 300 seals |
Special Features
Technical Data
Cat. No | KCM | KCM-B |
---|---|---|
Readability | 1 ml / 1g | 1 ml / 1g |
Display | Large LCD | Large VFT |
Alarm | Audio-Visual | Audio-Visual |
Input Voltage | 230V AC(SMPS). | 90-270V AC (SMPS) |
Battery Backup | -------- | 6 to 8Hrs |