Post Buy Requirement
Krish Engineers
Ahmedabad, Gujarat, India
Verified Add Review

Other Products / Services #3844244

Bus Duct Panel

Bringing forth wide array of Bus Duct Panels, we are amidst the celebrated Suppliers in this field. Capitalizing on an efficient industrial network, our organization has made coalitions with numerous reputed logistics solution sources. Thus, we can ensure on time distribution of consignments.

View Complete Details

APFC Panel

The company is deep rooted in Ahmedabad(India) and has gained a distinguished position in the market. Owing to our excellent Ahmedabad(India), we efficiently make on-time deliveries to the customers.

View Complete Details

PCC Panel

5 Lakh /Set Get Latest Price
  • Min. Order (MOQ) 01 Set(s)
  • Place of Origin Ahmedabad

We manufacture all type of pcc panels as per consultant specification. Approximate price per kva is rs 1200-

View Complete Details

MCC Panel

Thanks to our immense expertise of the domain, we as a Supplier, strives to deliver nothing short of excellence to our customers. Backed by a team of deft professionals, it has become easy for us to furnish divisive demands of the buyers and that too within shortest time possible.

View Complete Details

Lighting Panel

We have numerous dealers and distributors associated with us to make our products available to buyers with ease and make timely delivery. Founded in Ahmedabad(India), our company has been successful in capturing the local and domestic markets as trader of this product

View Complete Details

Automation Panel

For keeping the quality of the products intact, our quality experts check all levels including procurement of raw materials, production, packaging and dispatch. As a known name, we ensure safe and timely delivery of the orders at any desired Ahmedabad(India).

View Complete Details

Vacuum Circuit Breaker

Vacuum Circuit Breaker Widely Regarded As VCB Is Distinctive Breaker Which Used Vacuum As An Arc Extinction Medium. In Vacuum Circuit Breaker (VCB), The Fixed & Moving Contact Is Encircled In A Permanently Sealed Vacuum Interrupter. The Arc Is Defunct As The Contacts Are Separated In High Vacuum. It Is Principally Used For Medium Voltage Ranging From 11 KV To 33 KV. Krish Engineer Is An Economical Manufacturer & Supplier Of Quality Vacuum Circuit Breaker (VCB) In Ahmedabad, Gujarat. Customer Can Avail Good Quality Of This Kind Of Circuit Breaker At Our Factory.

Salient Features:

Our Manufactured Vacuum Circuit Breaker (VCB) Is Inbuilt With Following State Of The Art Features

  • Available In Fixed As Well As Drawout Versions
  • Can Be Customized To Suit Your Needs.
  • Drawout Truck Can Be Interlocked In TEST/SERVICE Position For Safety.
  • Individual Vacuum Interrupters Are Housed In Epoxy Housing With Suitable Clearances.
  • Compartmentalized Design With Separated Chambers For VCB Truck, CT, PT, Busbar And Metering.
  • Can Be Combined With Air/SF6 Load Break Switches In RMUs And Indoor Substations.
View Complete Details

Capacitor

Krish Engineers Is Manufacturer & Supplier Of Medium Frequency Water Cooled Capacitors In Ahmedabad, Gujarat.

Scope

Medium Frequency Water Cooled Capacitors From 1 KV Up To Maximum 5000 Volts, To Maximum 7000 KVAr And Frequency Up To 50 Kilocycles For Indoor Use.

  • with Dead Casing, Open Terminal (2 Bushings).
  • with Live Casing, Open Terminal (1 Bushing).

Applicable Standards

  • IEC 60110-1 Capacitors For Induction Heating & Melting Application.
  • IS 9251 Capacitors For Inductive Heat Generating Plants Operating At Frequencies Between 40 And 24000 Hz
  • DIN EN 60110-1 Power Capacitor For Induction Heating Installations.
  • VDE 05650-9:1999-09

Ratings

    • Voltage: Up To 5kV
    • Output Capacity: Up To 7200 KVAr
    • Frequency: Up To 50 KHz
    • Mounting: Suitable For Both Horizontal / Vertical
    • Container: Imported Embossed Aluminium Sheet.
    • Construction: Live / Isolated (Dead) Container

Safety

Over Pressure Dis-connector Provided With NC Contact.

Tests

Each And EveryMedium Frequency Water Cooled Capacitors Aresubjected To Routine Tests In Accordance To IEC 60110-1.

      • Measurement Of Capacitance.
      • Measurement Of Dielectric Loss Angle @ 50Hz.
      • Voltage Test Between Terminals
      • Voltage Test Between Terminals & Container
      • Sealing Test

Features:

Following Are The Saliet Features Of Our OfferedMedium Frequency Water Cooled Capacitors

      • Low Losses < 0.8 Watts Per KVAr
      • World Class Raw Materials
      • Manufactured In State Of Art Infrastructure
      • Volume Optimized And Highly Reliable
      • Trouble Free Long Life Performance
      • Environmentally Friendly.

Quality Management System

ISO 9001 Accredited ByTUV.

Safety Regulations

When Installing The Equipment, Relevant IEC Or VDE Recommendations Shall Be Observed.

Quality Management System

ISO 9001, BS 5750 Qualifications EDF (HN 54-5-05), CSA

Altitude

Medium Frequency Water Cooled Capacitorsare Designed To Operate At Altitudes Not Exceeding 1500 Mtrs.

Impregnant

TheMedium Frequency Water Cooled Capacitorsare Impregnated With A NON-PCB Based Fluid Which Is Jarylec C-1 01. This Dielectric Fluid Is Environmentally Acceptable, Eliminates Health And Environment Hazards.

Dielectric

An Imported All Film Dielectric Is Used And Consists Of Polypropylene In The Form Of Bi-axially Oriented Film, Hazy On Both Sides, And In 2 Or 3 Layers With End And Edge Folded Aluminum Foil As Electrodes.

Dielectric Losses

Dielectric Losses@ 50 Cis In Fresh Condition Are Approx. 0.2 To 0.3 Watts / Kvar Up To 5 KHz, And 0.5 Watts / Kvar Up To 50 KHz And Reduce After 500 Operating Hours To A Stable State. The Dielectric Losses, Depending On Capacitor Design, Shall Be Added To Losses Caused By:

      • Internal Discharge Resistors
      • Internal Connections

Permissible Overloads

Maximum Permissible Voltages Capacitors Are Designed For Operation At Voltage Levels According To The Following Table.

The Amplitudes Of The Over Voltages That Can Be Tolerated Withoutsignificant Deterioration Of The Capacitor Depend Up On The Duration, The Total Number And The Capacitor Temperature.

Discharging

Each Capacitor Unit Shall Be Provided With Means Of Discharging To 75V Or Less.

Switching Over Voltages

The Residual Voltage On A Capacitor Prior To Energization Shall Not Exceed 1 0% Of The Rated Voltage.

Maximum Permissible Currents

Capacitor Units Will Be Suitable For Continuous Operation At An R. M. S Current Of 1.30 Times The Current That Occurs At Rated Sinusoidal Voltage And Rated Frequency, Excluding Transients.

Manufacturing And Quality Control

Imported Bi-axially Oriented Double Hazy Polypropylene Film And 99.9% Pure Aluminum Foil Are Used As Dielectric And Electrode. Wrinkle Free Winding Of The Elements Is Carried In An Class 100 Environment On A Semi Automatic Winding Machine With Edge And End Folding Of The Aluminum Foil. This Is To Eliminate Overvoltage Stress At The Edges Of The Buried Area Of The Foil.

Each Wound Element Is Tested For Dry DC Overvoltage With Stand For Pin Holes And Adequacy Of Margins Between AI Foils. Numbers Of Elements Are Interconnected In Series - Parallel To Achieve The Desired Capacitance And Designed Voltage Rating Of The Capacitor.

The Dry Pack Is Wrapped With Several Layers Of High Quality Insulating Paper Before Inserting It Into A Pre Treated / Degreased Aluminum Container And The Top Lid Is Welded By Semiautomatic Pulsed TIG Welding Machine.

The Aluminum Sheet Used For Fabricating Containers Is Imported, Manufactured Of A Special Alloy With Its Surface Embossed. All Metal Parts Copper And Brass Are Silver Brazed To Ensure Homogeneous Joint.

Porcelain Bushings Of Desired BIL Are Leak Proof Fitted On The Lid As Required. The Terminals Are Manufactured From Extruded Brass And The Water Cooling Pipe Is Of 99.99% Pure Electrolytic Grade Annealed Copper And Pressure Tested For Leaks Before Fitting On The Pack. On Specific Request Of Client, Imported Over Pressure Switches Are Also Fitted On The Capacitors.

All The Joints Are Tightened With Torque Wrench And Are Locked To Ensure They Remain Perfectly Tight Always. The Capacitors Are Then Loaded In A PLC Controlled Autoclave For Uniform Heating @85C And Drying Under Vacuum Of 0.001 Torr For A Given Period. After Confirming The Quality Of Drying By Precision Online Monitoring Instruments, The Capacitors Are Then Impregnated Under Vacuum With Highly Purified And Degassed Jarylec C- 1O1. The Capacitors Are Then Subjected To All Routine Tests In Accordance To IEC-60110-1.

Un (V R.m.s) Maximum Duration Observation
1.00 Continuous Highest Average Value During Any Period Of Capacitor Energization
1.10 8 H In Every 24 H System Voltage Regulation And Fluctuations.
1.15 min In Every24 H System Voltage Regulation And Fluctuations.
1.20 5 Min Voltage Rise At Light Load
1.30 1 Min -

Life Expectancy

Based On The State Of Art Plant& Machinery, Quality Of Raw Materials Used, Manufacturing Under Strict Quality Control And Process Using Precision On Line Instruments, And Elevated Over Voltage Test Results Under Extreme Temperatures, Capacitors Are Assured Of Minimum 20 Years Life.

Electrical Tests

Each And EveryMedium Frequency Water Cooled Capacitors Aresubjected To Routine Tests In Accordance To IEC60110-1.

      • Measurement Of Capacitance.
      • Measurement Of Dielectric Loss Angle @ 50Hz.
      • Voltage Test Between Terminals 4 Vn For 10 Secs.
      • Voltage Test Between Terminals& Container 2.15 Vn.
      • Sealing Test @ 80C For 2hrs.

View Complete Details

Automatic Transfer Switch

Krish Engineer, A Company Based In City Of Ahmedabad Which Is Industrial Nucleus Of Gujarat State, Is A Leading Manufacturer & Supplier Of Range Of Automatic Transfer Switch. This Automatic Transfer Switch Are Design To Cater Low Voltages Power Networks And Manufactured Using The Fine Grade Of Material And Keeping In Mind The Latest Industrial Electrical Standard.

An Automatic Transfer Switch (ATS) Is A Type Of Switch Which Spontaneously Transfers A Power Supply From Its Principal Source To A Backup Source When It Senses A Failure Or Outrage In The Principal Source.

At Krish Engineer , Customer Can Avail Range OfAutomatic Transfer SwitchFor A System Ranges100 A -3000A.

We Are Pioneer Manufacturer Of ATS In Ahmedabad, Gujarat.The ATS Is Designed For Use In Low Voltage Power Networks In Order To Reduce And Virtually Eliminate Outage Periods Of Critical Loads.

ATS Range 100A 3000A

Salient Feature:

Following Are The Salient Feature Of Our ATS

  • Extended Product Lifetime Through Minimization Of Arcing Time.
  • 3 Stable Switch Positions (Main Source, Neutral, Emergency Source).
  • Individual Phase Enclosure To Improve Breaking Capacity.
  • Enhanced Main Contact Protection (Overload Capabilities)
  • Current Withstand Capacity: 10kA 100kA
  • Temporary Voltage Is Required
  • High Transfer Capabilities For Inductive And Motor Loads
  • Manual Change-over
  • Easy And Quick Installation
View Complete Details

Load Break Switch

Krish Engineer A Leading Company Is A Manufacturer & Supplier Of Range Of Load Break Switches Based In Ahmedabad, Gujarat. Load Break Switch Also Known As LBS. Load Break Switch (LBS) Is Typically Used In Medium Voltage Industry For Switching & Protection Purpose. A Load Break Switch Is A Disconnect Switch That Has Been Designed To Deliver Making Or Breaking Of Specified Currents.

Salient Features:

Our Ranges Of Load Break Switches Are Inbuilt With Following Outstanding Features.

  • Best Available Option For Protecting Transformers Up To 1000kVA In Indoor And Outdoor Versions
  • Fuse-trip Mechanism Which Eliminates Single-phasing
  • Complete Safety With Earth Switch Interlocked With Main Switch
  • Suitable For Capacitor Bank Switching
  • On-load/Off-load Isolators Are Available.
  • Electrical Tripping Through Shunt Coil (optional)
  • Type Tested For 11kV, 630A, 25kA And 22kV, 630A, 25kA.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Rajesh Narayan (Krish Engineers)
  • C-76, Maruti Industrial Estate, Near Choksi Tubes, GIDC Vatva, Ahmedabad, Gujarat - 382445
  • Share us via
  • Call 08068051406 Ext. 824