We offer a complete product range of Dynatrac Stress Test System

Dynatrac Stress Test System

  • Number Of Flower Test System
  • Application Reducing Stress
  • Availability 100-200kg
  • Packaging Type Available in Many Colors
  • Country of Origin 110V
  • Automatic Grade Automatic
  • Driven Type Electric
  • Total Carbohydrate 1year

In order to keep the quality of the products up to the mark, we check the entire range against varied quality parameters. Rely on us and place orders with us, timely deliveries will be straight to your doorstep!

Technical Specification

Data Acquisition Sampling Rate 400 Samples/sec.
Acquisition Simultaneous 12 lead acquisition, 12 bits
Leads Standard 12 leads : Acquired 8 leads, Reconstructed 4 leads (111, aVR, aVL, aVF)
Input Dynamics ± 300mV @ 0Hz; ± 10mV in pass band
Input Impedance >100M 0hms
Time Constant 3.2 Seconds
CMRR 90dB @ 50 Hz
DF Protaction Internal
Patient Leakage <10µA
Frequency Responce 0.5Hz to 100 Hz
Digital Filters (Liner Phase) Mains Interference : 50Hz Notch Filter (always present), Anti-Drift Filter : 0.5Hz (13dB) (always present)
Signal Processing ECG Analysis 200 Samples/sec.
QRS Detaction Single lead (Selectable)
Calculated Parameters ST-Leval, ST-Slope, HR, METS
Fiducial Points Auto or Manual Selection
Enlarged Median Lead Auto Lead selection (Lead having minimum ST level) or Manual Lead selection
Median update Interval Every 8 secs.
Display Display Resolution 1024 x 768
ECG Display Format 3 lead + 12 median or 6 lead + 12 median or 12 lead + 12 median
ECG Display Speed 25mm/sec. Or 50mm/sec.
ECG Dispalay Sensitivity 5 or 10 or 20 mm/mV
Event Marker Yes
Display Data HR, Target HR, BP, Stage Time, Test Time, Speed, Grade, METS, Protocol Stage, ST-Level, ST-Slope, Leadoff information and Patient Name
Filter 20Hz or 40Hz or no filter (Selectable)
Printing Print Formet User defined reports; Printout with / without grid
Paper Size Plain Paper A4 Size
Printing Speed 25mm/sec.
Printing Sensitivity 10mm/mV
Filter 20Hz or 40Hz or no filter (Selectable)
Printouts Automatic stage printouts and real time printouts
Review Full Disclosure ECG Beat-to beat raw ECG record of complete exercise
Marked Events Review of marked events
Trend Graphs Trend graph of HR, ST-Level, ST-Slope, BP and J-ampitude
Data Sotorage Local Storage On hard disk, separate folder for each test
External Storage Selected records can be exported to CD-ROMs
ECG Acquisition Device Power Input Throough USB
Power Consumption <1W
PC Communication Through USB
Operating Temprature 10 to 40o C
Relative Humidity 25 to 95% Non-condensing
Storage Temperature -10 to 50o C
Relative Humidity 10 to 95% non-condensing
Safety Standards IEC- 60601-1: Class ICF type
EMC IEC-60601-1-2
Dimension 170.5mm X 106.5mm x 22.5mm (length x width x height)
Weight < 400gms
Treadmill Power Input 230V 15A
PC Communication Through serial port (RS-232)
Protocols Supported Standard (Bruce, Mod. Brouce, Mod. Balke, Ellested and Naughton) or User definable
Total Length 1970mm
Total Width 700mm
Walking Area 1500 x 500mm
Belt Speed 0.8-16Kmph
Incline range 0.22%
Patient Weight Up to 180 Kg,

 

Note : Due to constant Upgradation Specification & Feature Subject to Change without prior notice