Leading Manufacturer, Supplier & Retailer of Low Temperature Bath and Glass Thermometer Calibration Bath.

Glass Thermometer Calibration Bath

  • Number Of Flower Temperature Calibration Bath
  • Availability 100-200kg
  • Country of Origin 380V
  • Automatic Grade Automatic
  • Driven Type Electric
  • Total Carbohydrate 2years

The Glass Thermometer Calibration Bath is used for determination of errors or differences from the true value. Our Glass Thermometer Calibration Bath measures and compares thermometer and associate instruments in the given range of -60oC to 300oC. We are a recognized Manufacturer, Exporter and Supplier of Glass Thermometer Calibration Bath in New Delhi, India.
Temperature can’t be measured entirely without error, so it is necessary to quantify these errors by Calibration of the Probe, with or without its associated display against the reference standard in the respective temperature range. Calibration is essential where traceability to a National Standard or International Standard in compliance to industrial requirement in ISO-9000 specification.
KVS Temperature Heating/Water/Cooling Baths may be used for temperature application like Calibration Measurement and Comparison of the Thermometers and Associate Instruments in the given range -60°C to 300°C.

 

Other Specifications

  • Bath Material :  S. S. 304 Grade
  • Stirrer :  Screw Type Brass Stirrer
  • Stirrer Size :  L 400-425 mm x Ø 50 mm
  • Cover Plate of Bath Chamber :  Hylem Sheet 19 mm thick to hold 5-6 Thermometers
  • Ø of Holes in the Cover Plate :  mm 8(2), 6(2), 10(1), 12(1) other than for Control RTD and Heating Rod.


Specifications of Clinical Thermometer Calibrator

  • Temperature Range : 30oC  to 50oC (Room Temperature should be 27oC ± 2oC).
  • Resolution of Display : 0.01oC
  • Stability : 0.05oC or better.
  • Accuracy : 0.05oC or better.
  • Settability :  0.01oC or better.
  • Bath Opening : Cover of the Bath will suitable to accommodate 36-Clinical  Thermometers of Ø 12 mm each simultaneously.
  • Control : Temperature controlled by Programmable Temperature Controller-cum-Indicator with display 0.01oC.
  • Bath Depth : 200 mm.
  • Traceability : National/International Standards.
  • Power Supply : 220-240 Volts, 50 Hz.
  • Safety :  Tripping by RCCB at overcurrent.
  • Standard :  IS - 3055 Part I-1994

Specifications

Model KVS 100-H
Water Bath
KVS 300-H
High Temp. Oil Bath
KVS 20-H/40-H/60-H
Low Temp. Bath
KVS 50-H
Clinical Thermometer Bath
Working Temp. Range Amb.+5 to 100oC 50 to 300oC – 20 to Amb.
– 40 to Amb.
– 60 to Amb.
30 to 50oC
Resolution of Display ± 0.01oC ± 0.01oC ± 0.01oC ± 0.01oC
Overall Temp. Stability ± 0.02oC to ± 0.05oC ± 0.05oC to ± 0.08oC ± 0.05oC to ± 0.1oC ± 0.05oC
Temperature Control Microprocessor
Based PID with RTD PT-100
Microprocessor
Based PID with RTD PT-100
Microprocessor
Based PID with RTD PT-100
Microprocessor
Based PID with RTD PT-100
Heater Wattage 750 Watt 1000 Watt 750 Watt 250 Watt
PT-100 Sensor 3-Leads 3-Leads 3-Leads 3-Leads
Safety Installation Drain Plug & Overflow Outlet for Expanded Bath Liquid Drain Plug & Overflow Outlet for Expanded Bath Liquid Drain Plug & Overflow Outlet for Expanded Bath Liquid Drain Plug & Overflow Outlet for Expanded Bath Liquid
Stirrer Motor Power 1/8 hp, 1425 rpm 1/8 hp, 1425 rpm 1/8 hp, 1425 rpm 1/8 hp, 1425 rpm
Bath Opening Dia x Depth 125 x 500 mm 125 x 500 mm 175 x 500 mm 200 x 300 mm
Overall Dimension 450 x 450 x 600 mm 450 x 450 x 600 mm 500 x 500 x 600 mm 340 x 340 x 400 mm
Filling Volume 10.0 ltr 12.0 ltr 12.0 ltr 15.0 ltr
Insulation - Fiber Wool & Puff Not Less Than 135 mm Not Less Than 135 mm Not Less Than 135 mm Not Less Than 100 mm
Mains Power Connections 220-240/50 V/Hz 220-240/50 V/Hz 220-240/50 V/Hz 220-240/50 V/Hz
Power Consumption 850 Watt 1500 Watt 3000 Watt 750 Watt maximum
Permissible Ambient Temp. 10 to 35oC 10 to 35oC 10 to 35oC 10 to 27oC










View Complete Details

Low Temperature Bath

  • Refrigeration Hermetically Sealed Cascade System (for Low Temp. Bath)
  • Heater S. S. Tubular Water Heater
  • Stirrer Motor For Homogenous Temperature
  • Insulation Puff / Mineral Wool
  • Chamber Double Walled
  • Interior Chamber S. S. 304
  • Exterior Chamber M. S. duly painted
  • Temperature Range Ambient to -50ºC (or as per Customer’s requirement)
  • Accuracy ± 1ºC
  • Sensor RTD Pt-100
  • Controller Digital Temperature PID Controller
  • Models Low Temp. Bath Amb to -50ºC / Water Bath upto 95oC / High Temperature Oil Bath upto 270oC

"K. V. Scientific" make Low Temperature Water Baths which are designed & fabricated to suit various I. S. Standards application in the growing field of Medical, Agricultural Institution, Bio-Chemical Industrial, Research Laboratories & various Industries.

Features

  • Durable Construction
  • Noiseless Operation
  • Safe for Operator & Samples
  • CFC-free Refrigerant (For Low Temp. Bath)
  • Handles & Castor Wheels for portability

 

View Complete Details