My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Electrotherapy Equipment 18 Products / Services available
  2. Physiotherapy Products & Equipment 6 Products available
  3. Diathermy Machines 5 Products available
  4. Tables 4 Products available
  5. Physiotherapy Equipment 3 Products available
  6. Cleaning Machines & Equipments 2 Products available
  7. Exercise Machines 2 Products available
  8. Health Care Products 2 Products available
  9. Bicycles 2 Products available
  10. Rehabilitation Equipment 2 Products available
  11. Exercise Machines & Equipment 1 Products available
  12. Hospital Equipment 1 Products available
  13. Hardware Fittings And Accessories 1 Products available
  14. Cardio Machines 1 Products available
  15. Gym Bar 1 Products available
  16. Slimming Machine 1 Products available
  17. Free Weights 1 Products available
  18. Exercise Accessories 1 Products available
  19. Exercise & Fitness Goods 1 Products available
  20. Lamps 1 Products available
  21. Suspension & Suspension Parts 1 Products available
  22. Electrosurgical Units 1 Products available
  23. Bathtub 1 Products available
  24. Surface Cleaner 1 Products available
  25. Industrial Chemicals 1 Products available
  26. Salon & Beauty Equipment 1 Products available
  27. Conveyor Roller 1 Products available
  28. Exercise Stepper 1 Products available
  29. Others Products / Services 19 Products / Services available

Electrosurgical Units

We are leaders in the market for providing best range of Electrosurgical Cautery Machine

Electrosurgical Cautery Machine

Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad)

Bipolar diathermy is the emitance of the HFAC from the electrosurgery diathermy down one prong of a bipolar forcep through the tissue that has been placed between the forcep tips and returned to the diathermy via the second prong. Bipolar diathermy does not require a dispersive electrode (patient return pad).

Background

Surgical instrument india has three effects on body tissue:

  • cut - generation of heat destroys tissue cell
  • coagulation - tissue cells contract to increase normal clotting
  • fulguration - cell walls destroyed through dehydration

Each of these processes generates smoke plume which contains:

  • chemical by-products (eg toluene, acrolein, formaldehyde, benzene and hydrogen cyanide)
  • intact cells, cell parts and intact viral DNA
  • viable bacteria, including mycobaterium tuberculosis, have also been cultured

To minimize associated health hazards, specially designed smoke evacuation systems should be used where available and surgical filtration masks donned for all surgical procedures.

Prior to use

The Electrosurgery Unit (ESU) should only be use by members of the peri-operative team deemed competent.

  • The ESU should be inspected and safety features tested (eg lights, activation patient return electrode sound indicator) before each use
  • All cables and electrodes must be checked prior to use to ensure insulation is intact
  • Any problems must be reported to the Biomedical Engineering Department immediately.
  • The volume of the activation sound indicator should be maintained at an audible level

General use

The diathermy surgery should be protected from spills. Fluids should not be placed on top of the ESU The dispersive electrode should be the appropriate size for the patients weight and an electrode should never be cut to size Only those active electrodes recommended by the manufacturer should be used. If an adapter is used it should be one that is approved by the manufacturer and does not compromise the generator's safety features.After the patient is positioned on the operating table, the dispersive electrode should be placed on a clean, dry intact skin surface over a large, well perfused muscle mass

The dispersive electrode should not be placed over.

  • a bony prominences
  • implanted metal prosthesis
  • areas distal to a tourniquets
  • scar tissue
  • hairy surfaces
  • pressure points/areas

The electrode should be positioned as close to the operative site as possible The dispersive electrode should be connected to the ESU prior to draping to ensure adequate contact & then the lead disconnected from the ESU temporarily to allow for the draping of the patient and the positioning of the surgeon

Mono Polar/Bipolar Surgical Diathermy AYU 250 ANL is a high frequency Electro Surgical Unit Micro controller based innovative design, together with high reliability makes AYU 250 ANL Electro Surgical Diathermy unit the most favorable choice of doctors. The technical ability of the unit is combined with patient's safety that are of prime importance both for patient and the user. The AYU 250 ANL Electro Surgical Diathermy is designed with SMPS power supply which provides particular safety and reliability. AYU 250 ANL is user friendly Electro Surgical unit.

SAFETY IN USE The Technical conceptions of the AYU 250 ANL meet the requirements of highly refined Electro Surgical techniques all national and international safety standards are confirmed. The micro function and knob allows for an instant variation in the output power for more delicate application such as neurological or micro surgery.

  • Ortho Peallic

  • Dermatology

  • Otolaryngology

  • Ophthalmology

  • Ginaecology

  • Aesthetics

  • Vascular Disease

  MODE RATED LOAD (OHMS) MAXIMUM POWER(WATTS)
Monopolar
Cut
Pure
Blend
300
300
250
180
Monopolar
Coag.
Force
Soft
300
300
180
150
Bipolar
Cut
Pure
Blend
100
100
100
70
Bipolar
Coag
Force
Soft
100
100
70
50

Unit Size      -     L*W*H - 335x330x125 mm
Box Size      -     L*W*H - 430x405x280 mm
Net Weight    -   5kg.200gm      Gross Weight - 10kg . 500gm