Our Products
Our offered Product range includes Induction Motors, Split Case Fire Pump, Submerged Centrifugal Pumps, Grinder Pump and Pressure Booster Pump.
Lubi offers FLHC series state-of-the-art fire pumps with diesel engine/electric motor driven, horizontal split case pump.These pumps are typically used in fire-fighting applications for supplying water to fire hose reels, fire hydrants or sprinkler systems.50Hz Pumps have a discharge range from 450 to 1250 USgpm and the head range from 61 to 233 psi.
60Hz Pumps have a discharge range from 450 to 750 USgpm and the head range from 6.4 to 14.65 bar.These fire pumps meet or exceed the requirements of NFPA20.Installations of these pumps would ensure the safety of human life, buildings, expensive plants and equipments.FLHC fire pumpset shall be used only where a positive suction is provided as specified in NFPA20.The fire pumps typically consists of the following equipments:PumpElectric motor/Diesel engine assembled withcooling system (for Diesel engine only)fuel system (for Diesel engine only)battery system (for Diesel engine only)exhaust system (for Diesel engine only)Fire pump controllerSuction and discharge gaugesAir relief valveCommon base plate
Note:For your jockey pump requirements kindly refer our literature for LCR and/or LES pumps.All above equipments except fuel supply tank and fire pump controller are mounted on a common base frame.Lubi can also supply Packaged fire pumping system with all required accessories ready for site installation.
APPLICATION
The FLHC fire pumps are used in fire-fighting applications for supplying water to fire hose reels, fire hydrants or sprinkler systems in areas which are prone to the hazards of fire.The typical applications are as follow:Commercial complexes and high rise buildingsPetrochemical industries and Gas plantsOil and Gas on-shore &off-shore platformsOil terminalsAirports and portsJettiesMarine applicationsPower stations and transformer stationsChemical industriesManufacturing plantsFire-work industriesWarehouses/godowns.
FEATURES
FLHC fire pumps offers all features & benefits as mentioned in our LHC standard pump series data booklet. Following are the additional features & benefits offered by these pumps:State-of-the-art design fire pumping system.UL listed/FM approved/NFPA-20 designDiesel engine as well as electric motor driven pumpRugged constructionLiberal water passagesAutomatic air relief valveEfficient operationLower initial costReduced installation time and costSimplified piping designSuitable for space saving installation systems and retrofit applicationsEasy access to all working partsEase of maintenanceSingle source unit responsibility.
Lubi offers FLBS series state-of-the-art fire pumps with diesel engine or electric motor driven, single-stage End-Suction pump.
These pumps are typically used in fire-fighting applications for supplying water to fire hose reels, fire hydrants or sprinkler systems.
50Hz Pumps have a discharge range from 50 to 1000 USgpm and the head range from 3.72 to 9.9 bar.
60Hz Pumps have a discharge range from 100 to 1250 USgpm and the head range from 5.24 to 20.61 bar.
These fire pumps meet or exceed the requirements of NFPA20.
Installations of these pumps would ensure the safety of human life, buildings, and expensive equipments and plants. FLBS fire pumpset shall be used only where a positive suction is provided as specified in NFPA20.There fire pumps typically consists of the following equipments:Single-Stage End-Suction pumpElectric motor or Diesel EngineCooling system for Diesel EngineFuel system for Diesel EngineBattery for Diesel Engine electric startExhaust system for Diesel EngineDiesel Engine / Electric Motor Fire pump controllerSuction and Discharge pressure gaugesCasing Relief Valve for Motor Fire pumpBase frame
All above equipments except fuel supply tank and fire pump controller are mounted on a common base frame.
Lubi can also supply packaged fire pumping system with all required accessories ready for site installation.
APPLICATION
The FLBS fire pumpsets are used in small capacity, diesel engine or motor driven fire-fighting applications for supplying water to fire hose reels, fire hydrants or sprinkler systems in areas which are prone to the hazards of fire.
The typical applications are as follow:Commercial complexes & high rise buildingsPetrochemical industries and Gas plantsAirports and portsJettiesMarine applicationsPower stations and transformer stationsChemical industriesManufacturing plantsFire-work industriesWarehouses / godowns
FEATURES.
FLBS fire pumpset offers all the features & benefits as mentioned in our LBS standard pump series data booklet. Following are the additional features & benefits offered by these pumpsets:State-of-the-art design fire pumping system.NFPA-20 designCompact diesel engine driven pump packageRugged constructionMore economical than Horizontal Split Case diesel fire pump packagesBack pull-out design which simplifies inspection and maintenance without disturbing pipe workThe pump impellers are dynamically balanced to grade 6.3 of ISO 1940-1Efficient operationLower initial costReduced installation time and costEasy access to all working partsEase of maintenanceSingle source unit responsibility.
Lubi brand Horizontal split case pump useful for high flow water pumping. Horizontal split case pump ideally suitable for industrial community water pumping, lift irrigation, Fire fighter and water distribution. The pumps are non self priming horizontal split case pumps with radial suction port and radial discharge port. The double suction design helps pump to balance the forces on impeller and split case design offer fast maintenance & lower down time. The pumps have horizontal pump shaft and the volute casing can be dismantled in the horizontal plane along the drive shaft. Horizontal split case pumps are available in two main designs. 1) Single stage 2) Two stage
APPLICATION
FEATURES
LBSBare shaft pumpideally designed for clear water circulation. The back pull out design enables the user to easily maintain the pump without distribution the pipe line. Single stage bare shaft pumps are in according to ISO 2858 & DIN 24255. Standard flanges are PN 16 as per DIN standard EN 1092-2 and PN 25 as per DIN standard EN 1092-2. ANSI 125 and ANSI 250 as per ASME B16.1 are available on request. Material of Construction of Bare Shaft Pump is available in Cast Iron, Bronze & Stainless Steel.
APPLICATION
FEATURES
LES are single-stage End-suction pump according to ISO 2858. Our range also includes several models of pumps which have been developed with duty condition which are not covered in ISO 2858. The volute casing of End suction pump is designed to be robust in construction to take the undue stresses offered by the pipe work. They have an axial suction port and radial discharge port. Standard flanges are PN 16 as per DIN standard EN 1092-2 and PN 25 as per DIN standard EN 1092-2. ANSI 125 and ANSI 250 as per ASME B16.1 are available on request
APPLICATION
LES are single-stage End-suction pump according to ISO 2858. Our range also includes several models of pumps which have been developed with duty condition which are not covered in ISO 2858. The volute casing of End suction pump is designed to be robust in construction to take the undue stresses offered by the pipe work. They have an axial suction port and radial discharge port. Standard flanges are PN 16 as per DIN standard EN 1092-2 and PN 25 as per DIN standard EN 1092-2. ANSI 125 and ANSI 250 as per ASME B16.1 are available on request
APPLICATION
FEATURES
LES are single-stage End-suction pump according to ISO 2858. Our range also includes several models of pumps which have been developed with duty condition which are not covered in ISO 2858. The volute casing of End suction pump is designed to be robust in construction to take the undue stresses offered by the pipe work. They have an axial suction port and radial discharge port. Standard flanges are PN 16 as per DIN standard EN 1092-2 and PN 25 as per DIN standard EN 1092-2. ANSI 125 and ANSI 250 as per ASME B16.1 are available on request
Flow rate up to 90 l/min (5.4 m/h)
Dynamic head up to 40 m.
APPLICATION
clean liquids without abrasives, which are non-aggressive for the pump materials.
water supply.
As pressure boosting pumps for central water systems.
civil ad industrial applications.
watering gardens.
irrigation.
FEATURES
Other voltages.
Available in three phase.
Special mechanical seal.
Higher liquid or ambient temperatures.
Available in 60 Hz.