Post Buy Requirement
ME
Noida, Uttar Pradesh, India
Verified Add Review

Our Products #6802808

Chrome Purifier Unit

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction ofBright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Chrome Purifying System - 18 Ltrs

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction ofBright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
Trade Information
View Complete Details

Chrome Purifying System - 3 Ltrs

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction of Bright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Multi Diaphragm Chrome Purifying System

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction ofBright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Chrome Purifying System - 8 Ltrs

product description

mahalaxmi enterprises has developed chrome purifying system for the requirements of small and large bath volumes of chrome electroplating.this systems collects metallic impurities dissolved in all types of chrome solutions includingiron, copper, nickel, aluminum, zinc & trivalent chrome.

technology:

our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andtrivalent chrome migrate through the diaphragm to the cathodic compartment.cr3+removal rate of approx 130-150 gm per ltr of diaphragm solution per 24 hrs.

advantage :

  • this systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of cr3+.
  • no need to dump the chrome solution for reducing the impurities as they will be continuouslyremoved.
  • the single diaphragm chrome purifying systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • this systems takes very little space, so that the operator does not face any kind of problem.
  • the same dc rectifier which used for the chrome plating can be used in parallel for this systems.
  • this systems can be used while the plant is in operation.
  • maintenance cost equal to almost zero.
  • easy to use.

problems faced when the metallic impurities gets too much:

  • nodular deposit.
  • deposits dull
  • reduction in cathode efficiency
  • reduction in plating rate.
  • reduction ofbright range.
  • reduction in covering power.
  • more variation in deposit thickness(dog bone effect)
  • pitted deposit.
  • poor adhesion
  • pin holes
.
View Complete Details

Chrome Recovery Unit

product description

mahalaxmi enterprises has developed chrome recovery(collector) system for the requirements of small and large bath volumes of all type chrome electroplating.this systems recover pure chrome from drag/rinse solutions of chrome bath.

technology:our chrome recovery(collector)system technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.chrome migrate through the diaphragm to the anodic compartment.the recover chromic acid rate of approx 5 gm per ltr/hours of diaphragm solution.

operations:

  • the single diaphragm chrome recovery(collector)system can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • after install the chrome collector(recovery) system, fill the diaphragm with the drag out solution and start the dc rectifier, which means unit has been started.
  • the cr3+present inside the anodic chamber and as well as in the outer chamber is continuously oxidised to cr6+ at the respective anodic terminals , and the cr6+ being anionicin naturally, gets collected inside the central anodic chamber.
  • after some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.

advantage :

.
View Complete Details

Single Diaphragm Chrome Recovery Unit

Product Description

Mahalaxmi Enterprises has developed Chrome Recovery(Collector) System for the requirements of small and large bath volumes of all Type Chrome Electroplating.This systems recover pure chrome from drag/rinse solutions of chrome bath.

Technology:Our Chrome Recovery(Collector)System technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.Chrome Migrate through the diaphragm to the anodic compartment.The recover chromic acid rate of approx 5 gm per Ltr/hours of diaphragm solution.

Operations:

  • The Single Diaphragm Chrome Recovery(Collector)System can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • After install the Chrome collector(Recovery) system, fill the diaphragm with the drag out solution and start the DC rectifier, which means unit has been started.
  • The Cr3+present inside the Anodic chamber and as well as in the outer chamber is continuously oxidised to Cr6+ at the respective anodic terminals , and the Cr6+ being anionicin naturally, gets collected inside the Central anodic Chamber.
  • After some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.
Advantage :
  • This system can be operated continuously with the plating process thereby allowing continuous collected pure chrome and can be directly added to the plating bath. .
  • Decreasing the concentration of hexavalent chrome in the drag out.
  • Decreasing the cost of Chrome bath replenishment and at the same time the cost of ETP chemicals
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use
View Complete Details

Etching Purifier Unit

product description

mahalaxmi enterprises has developed abs etching purifying system for the requirements of small and large bath volumes of all type chrome electroplating. This systems collects all impurities dissolved in all types ofchrome solutions includingdecorative chrome, chromic acid plastic etching (abs).thissystems could be installed right inside the working etching solution bath used in the abs plating process.

technology:

our abs etching purifying systems technology is based on electro- dialysis method using diaphragm for the removal of unwanted trivalent chrome and the stoppage of discarding the

etching solution.our system removetrivalent chrome migrate through the diaphragm to the cathodic compartment. Cr3+removalrate of approx 130-150 gm per ltr of diaphragm solution per 24 hrs.

advantage :

  • this systems can be operated continuously with the plating process thereby allowing continuousremoval ofimpurities and oxidation of cr3+.
  • the single diaphragm etching purifying systems can be installed on one side of the cathodic bus bar or at the corner of the working bath, whichever is comfortable for the operator.
  • this systems takes very little space, so that the operator does not face any kind of problem.
  • thesame dc rectifier which used for the chrome plating can be used in parallel for this systems.
  • this systems can be used while the plant is in operation.
  • maintenance cost equal to almost zero.
  • easy to use.

problems faced when the impurities gets too much:

  • non uniform etching.
  • deposits dull.
  • reduction in plating rate.
  • reduction in covering power.
  • skip plating.
  • pitted deposit.
  • poor adhesion
  • pin holes
View Complete Details

Etching Purifier System

Product Description

Product Description

Mahalaxmi Enterprises has developed ABS Etching Purifying System for the requirements of small and large bath volumes of all type Chrome Electroplating. This systems collects all impurities dissolved in all types ofchrome solutions includingDecorative chrome, Chromic acid Plastic Etching (ABS).Thissystems could be installed right inside the working Etching solution bath used in the ABS plating process.

Technology:

Our ABS Etching Purifying Systems technology is based on electro- dialysis method using diaphragm for the removal of unwanted trivalent chrome and the stoppage of discarding the

etching solution.Our system removeTrivalent Chrome Migrate through the diaphragm to the cathodic compartment. Cr3+removalrate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuousremoval ofimpurities and oxidation of Cr3+.
  • The Single Diaphragm Etching Purifying Systems can be installed on one side of the cathodic bus bar or at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • Thesame DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the impurities gets too much:

  • Non uniform Etching.
  • Deposits Dull.
  • Reduction in plating rate.
  • Reduction in covering Power.
  • Skip Plating.
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

ABS Etching Purifier System

Product Description

Mahalaxmi Enterprises has developed ABS Etching Purifying System for the requirements of small and large bath volumes of all type Chrome Electroplating. This systems collects all impurities dissolved in all types ofchrome solutions includingDecorative chrome, Chromic acid Plastic Etching (ABS).Thissystems could be installed right inside the working Etching solution bath used in the ABS plating process.

Technology:

Our ABS Etching Purifying Systems technology is based on electro- dialysis method using diaphragm for the removal of unwanted trivalent chrome and the stoppage of discarding the

etching solution.Our system removeTrivalent Chrome Migrate through the diaphragm to the cathodic compartment. Cr3+removalrate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuousremoval ofimpurities and oxidation of Cr3+.
  • The Single Diaphragm Etching Purifying Systems can be installed on one side of the cathodic bus bar or at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • Thesame DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the impurities gets too much:

  • Non uniform Etching.
  • Deposits Dull.
  • Reduction in plating rate.
  • Reduction in covering Power.
  • Skip Plating.
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Cuboidal Chrome Purifying System In Operation

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction ofBright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Chrome Collector Unit

Product Description

Mahalaxmi Enterprises has developed Chrome Recovery(Collector) System for the requirements of small and large bath volumes of all Type Chrome Electroplating.This systems recover pure chrome from drag/rinse solutions of chrome bath.

Technology:Our Chrome Recovery(Collector)System technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.Chrome Migrate through the diaphragm to the anodic compartment.The recover chromic acid rate of approx 5 gm per Ltr/hours of diaphragm solution.

Operations:

  • The Single Diaphragm Chrome Recovery(Collector)System can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • After install the Chrome collector(Recovery) system, fill the diaphragm with the drag out solution and start the DC rectifier, which means unit has been started.
  • The Cr3+present inside the Anodic chamber and as well as in the outer chamber is continuously oxidised to Cr6+ at the respective anodic terminals , and the Cr6+ being anionicin naturally, gets collected inside the Central anodic Chamber.
  • After some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.
Advantage :
  • This system can be operated continuously with the plating process thereby allowing continuous collected pure chrome and can be directly added to the plating bath. .
  • Decreasing the concentration of hexavalent chrome in the drag out.
  • Decreasing the cost of Chrome bath replenishment and at the same time the cost of ETP chemicals
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use
View Complete Details

Chrome Recovery System

Product Description

Mahalaxmi Enterprises has developed Chrome Recovery(Collector) System for the requirements of small and large bath volumes of all Type Chrome Electroplating.This systems recover pure chrome from drag/rinse solutions of chrome bath.

Technology:Our Chrome Recovery(Collector)System technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.Chrome Migrate through the diaphragm to the anodic compartment.The recover chromic acid rate of approx 5 gm per Ltr/hours of diaphragm solution.

Operations:

  • The Single Diaphragm Chrome Recovery(Collector)System can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • After install the Chrome collector(Recovery) system, fill the diaphragm with the drag out solution and start the DC rectifier, which means unit has been started.
  • The Cr3+present inside the Anodic chamber and as well as in the outer chamber is continuously oxidised to Cr6+ at the respective anodic terminals , and the Cr6+ being anionicin naturally, gets collected inside the Central anodic Chamber.
  • After some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.

Advantage :

  • This system can be operated continuously with the plating process thereby allowing continuous collected pure chrome and can be directly added to the plating bath. .
  • Decreasing the concentration of hexavalent chrome in the drag out.
  • Decreasing the cost of Chrome bath replenishment and at the same time the cost of ETP chemicals
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
View Complete Details

Chrome Collector System

Product Description
Mahalaxmi Enterprises has developed Chrome Recovery(Collector) System for the requirements of small and large bath volumes of all Type Chrome Electroplating.This systems recover pure chrome from drag/rinse solutions of chrome bath.

Technology:Our Chrome Recovery(Collector)System technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.Chrome Migrate through the diaphragm to the anodic compartment.The recover chromic acid rate of approx 5 gm per Ltr/hours of diaphragm solution.

Operations:

  • The Single Diaphragm Chrome Recovery(Collector)System can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • After install the Chrome collector(Recovery) system, fill the diaphragm with the drag out solution and start the DC rectifier, which means unit has been started.
  • The Cr3+present inside the Anodic chamber and as well as in the outer chamber is continuously oxidised to Cr6+ at the respective anodic terminals , and the Cr6+ being anionicin naturally, gets collected inside the Central anodic Chamber.
  • After some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.
Advantage :
  • This system can be operated continuously with the plating process thereby allowing continuous collected pure chrome and can be directly added to the plating bath. .
  • Decreasing the concentration of hexavalent chrome in the drag out.
  • Decreasing the cost of Chrome bath replenishment and at the same time the cost of ETP chemicals
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use
View Complete Details

Cuboidal Diaphragm Chrome Purifying System

Product Description

Mahalaxmi Enterprises has developed Chrome Purifying System for the requirements of small and large bath volumes of Chrome Electroplating.This systems collects metallic impurities dissolved in all types of chrome solutions includingIron, Copper, Nickel, Aluminum, Zinc & Trivalent Chrome.

Technology:

Our system remove all metallic impurities (such as iron, copper, nickel, aluminum and zinc) andTrivalent Chrome Migrate through the diaphragm to the cathodic compartment.Cr3+removal rate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuous removal of metallic impurities and oxidation of Cr3+.
  • No need to dump the Chrome solution for reducing the impurities as they will be continuouslyremoved.
  • The Single Diaphragm Chrome Purifying Systems can be installed on one side of the cathodicbus baror at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the metallic impurities gets too much:

  • Nodular deposit.
  • Deposits Dull
  • Reduction in Cathode Efficiency
  • Reduction in plating rate.
  • Reduction ofBright Range.
  • Reduction in covering Power.
  • More variation in Deposit Thickness(Dog bone effect)
  • Pitted Deposit.
  • Poor Adhesion
  • Pin Holes
View Complete Details

Chrome Recovery Plant

Product Description

Mahalaxmi Enterprises has developed Chrome Recovery(Collector) System for the requirements of small and large bath volumes of all Type Chrome Electroplating.This systems recover pure chrome from drag/rinse solutions of chrome bath.

Technology:Our Chrome Recovery(Collector)System technology is based on electro-dialysis method using diaphragm for the recover the pure chrome from drag out solution of chrome bath.Chrome Migrate through the diaphragm to the anodic compartment.The recover chromic acid rate of approx 5 gm per Ltr/hours of diaphragm solution.

Operations:

  • The Single Diaphragm Chrome Recovery(Collector)System can be installed on one side of the anodic bus bar or at the corner of the drag out/rinse bath, whichever is comfortable for the operator
  • After install the Chrome collector(Recovery) system, fill the diaphragm with the drag out solution and start the DC rectifier, which means unit has been started.
  • The Cr3+present inside the Anodic chamber and as well as in the outer chamber is continuously oxidised to Cr6+ at the respective anodic terminals , and the Cr6+ being anionicin naturally, gets collected inside the Central anodic Chamber.
  • After some you will see that chrome concentration increased inside the diaphragm, then we will use this pure chrome in main chrome bath, and again diaphragm will fill by drag out solution and start the system continuously.
Advantage :
  • This system can be operated continuously with the plating process thereby allowing continuous collected pure chrome and can be directly added to the plating bath. .
  • Decreasing the concentration of hexavalent chrome in the drag out.
  • Decreasing the cost of Chrome bath replenishment and at the same time the cost of ETP chemicals
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • The same DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use
View Complete Details

ABS Etching Purifying System

Product Description

Mahalaxmi Enterprises has developed ABS Etching Purifying System for the requirements of small and large bath volumes of all type Chrome Electroplating. This systems collects all impurities dissolved in all types ofchrome solutions includingDecorative chrome, Chromic acid Plastic Etching (ABS).Thissystems could be installed right inside the working Etching solution bath used in the ABS plating process.

Technolagy

Our ABS Etching Purifying Systems technology is based on electro- dialysis method using diaphragm for the removal of unwanted trivalent chrome and the stoppage of discarding the

etching solution.Our system removeTrivalent Chrome Migrate through the diaphragm to the cathodic compartment. Cr3+removalrate of approx 130-150 gm per Ltr of diaphragm solution per 24 Hrs.

Advantage :

  • This systems can be operated continuously with the plating process thereby allowing continuousremoval ofimpurities and oxidation of Cr3+.
  • The Single Diaphragm Etching Purifying Systems can be installed on one side of the cathodic bus bar or at the corner of the working bath, whichever is comfortable for the operator.
  • This systems takes very little space, so that the operator does not face any kind of problem.
  • Thesame DC Rectifier which used for the Chrome plating can be used in parallel for this systems.
  • This systems can be used while the plant is in operation.
  • Maintenance cost equal to almost Zero.
  • Easy to use.

Problems faced when the impurities gets too much:

  • Non uniform Etching.
  • Deposits Dull.
  • Reduction in plating rate.
  • Reduction in covering Power.
  • Skip Plating.
  • Pitted Deposit.
  • Poor Adhesion