Our Products
Our offered Product range includes Non Reset Type Mechanical Stroke Counter, Reset Type Mechanical Stroke Counter, Electromagnetic Pulse Counter, Electromagnetic Pulse Counters and Mechanical Stroke Counters.
| Model - Reset Type | Drive | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S-109 R | L.H. Top Coming | |||||||||||||||
| S-110 R | L.H. Top Going | |||||||||||||||
| S-111 R | R.H. Top Coming | |||||||||||||||
| S-112 R | R.H. Top Going | |||||||||||||||
| ||||||||||||||||
Specifications(Electrical)
| Rated Voltage | Coil Resistance at 20 deg. C | Rated Current | Consumption of power (Rating) |
|---|---|---|---|
| 4VDC 12V DC 24V DC | 30 Ohms 100 Ohms 590 Ohms | 130 mA 120 mA 41 mA | 0.5W 1.5W 1 W |
Specifications(Mechanical)
| Max. Counter Speed | 600 C P M |
|---|---|
| Colour of figures | White on black background |
| Size of figures | 3 mm x 2 mm |
| Counter index at delivery | 000000 + 10 |
| Reset Function | not available |
| Cover Material | ABS Black / ACRYLIC Black |
| Lead wire | 110 mm +/-10 mm length |
| Lead Wire Pull Out Force | 3Kg.Max. |
| Pulse Duration | 50 ms ON(min) 50 ms OFF(min) |
| Life | 3 10 x Counts |
| Counting Accuracy | The Counting error shall not exceed +/-1 in every 100,000 counts |
Specifications
| Counter speed | 300 counts/minute |
|---|---|
| Character colour | {I}White on black background {II}One decimal or two decimal where decimals are white on red background as required |
| Character Size | 2.3mm X 1.6mm |
| Counter display at delivery | 00000 + 10 (indicated number) |
| Zero reset | Not available |
| Cover material | ABS Black |
| Lead Wire | 110 mm ± 10mm length Lead wire shall with stand 3 kg pull out force |
| Mounting | M4 x 12 Screw and Nut Provided at the rear. |
| Working Voltage | 12 VDC/24VDC |
| Coil Resistance | 100 ohms / 150 ohms ±5% at 20°C - 12 VDC 220 ohms / 470 ohms ±5% at 20oC - 24 VDC |
| Dielectric Strength | 2 KV AC |
| Life Test | Sample of 5 counters are tested periodically for 3 million counts at the specified working voltage and an operating cycle of 100 m sec ON and 100 m sec OFF. |
| Counting Accuracy | not exceed ± 1 in every 100,000 counts |
| Testing | Operating Voltage Coil Resistance Length of lead wire |
Specifications
| Counter speed` | 300 counts/minute |
|---|---|
| Character colour | {I}White on black background {II}One decimal or two decimal where decimals are white on red background as required |
| Character Size | 5mm X 3mm |
| Counter display at delivery | 000000 + 10 (indicated number) |
| Zero reset | Not available |
| Cover material | ABS Black |
| Lead Wire | 110 mm ± 10mm length Lead wire shall with stand 3 kg pull out force |
| Mounting | 2 M3 Tapped holes provided at the rear |
| Working Voltage | 12 VDC/24VDC |
| Coil Resistance | - 100 ohms / 150 ohms ± 5% at 20oC - 12 VDC - 220 ohms / 470 ohms ± 5% at 20oC - 24 VDC |
| Dielectric Strength | 2 KV AC |
| life Test | Sample of 5 batch, for 3 million counts.at the working voltage and an operating cycle of 100 mm sec 'ON' and counters from every100m.sec 'OFF'. |
| Counting Accuracy | not exceed ± 1 in every 100,000 counts |
| Testing | Operating Voltage Coil Resistance Length of lead wire |
| Optional | Mounting Brackets CRCA Zinc Blue plated metal encapsulation |
Specifications
| Counter speed | 300 counts/minute |
|---|---|
| Character colour | {I}White on black background {II}One decimal or two decimal where decimals are white on red background as required |
| Character Size | 2.3mm X 1.6mm |
| Counter display at delivery | 000000 + 10 (indicated number) |
| Zero reset | Not available |
| Cover material | ABS Black |
| Lead Wire | 110 mm ± 10mm length Lead wire shall with stand 3 kg pull out force |
| Mounting | 1 M3 Tapped Hole Provided at the rear |
| Working Voltage | 12 VDC/24VDC |
| Coil Resistance | 100 ohms / 150 ohms ±5% at 20°C - 12 VDC 220 ohms / 470 ohms ±5% at 20°C - 24 VDC |
| Dielectric Strength | maximum 2 KV AC, subject to gauge of copperwire |
| Life Test | Sample of 5 counters are tested periodically for 3 million counts at the specified working voltage and an operating cycle of 100 m sec ON and 100 m sec OFF. |
| Testing | Operating Voltage Coil Resistance Length of lead wire |