Our Products
We are leaders in the market for providing best range of Freezing Point Osmometer and Jaundice Meter
Osmometer The offered array of products is examined on the basis of quality of raw material and other inputs used for the manufacturing. Rest assured us for the raw material used, as we have most updated technologies to examine the quality. We stringently follow the safety packaging guidelines, thus we are flexible enough in delivering the products to the clients. We only use the finest packaging material to evade loss during transit.
Other Details:
Clinical Applications of Osmometry:
Additional Information:
Payment Terms : T/T
Technical Specification
| Communications | DTE EIA-232/V.24 (RS232), parallel printer, and optional barcode scanner |
|---|---|
| Drift | Less than 1 digit per month plus 1 digit for every 9°F or 5°C ambient temperature change |
| Frequency | 50 or 60 Hz |
| Linearity | < 1% of straight line between calibration points of 50 and 850 mOsm |
| Memory Backup | Integral lithium cell; ten years minimum; retains last 30 measurements |
| Power | 60 Watts |
| Range | 0 to 2000 mOsm/kg H2O |
| Repeatability | ± 2 mOsm/kg H2O (1 S.D.) between 0 and 400 mOsm/kg H2O; ± 0.5% (1 S.D.) between 400 and 2000 mOsm/kg H2O |
| Room Humidity | 5 to 80% relative humidity, non-condensing |
| Sample Volume | 20µL |
| Shipping | 20.5 lbs (9.1 kg) |
| Test Time | 90 seconds per sample |
| Voltage | 90 to 240 VAC |
| Warranty | One-year limited warranty on workmanship and all parts except glass, plastic and parts warranted by their makers |
We are well equipped with the most recent machines and technology that help us in conducting stringent check on the raw materials that are used while manufacturing. Each consignment of ours is packaged carefully utilizing premium packaging supplies and technologies in order to maintain the products' environment and quality during shipping and handling.
Bilitest : device for objective evaluation of hyperbilirubinemia level in newborns using non-invasive transcutaneous method.
The intended use of the Bilitest Hyperbiliruinemia Analyzer is to screen newborn infants for hyperbilirubinemia, including :
Commonly in newborns bilirubin determination is performed on a forehead near nose or on the upper part of the breast. Only a slight touch of a mobile measuring head to a baby’s derma is needed for measuring. The result is given in international units for transcutaneous bilirubin index (TBI). This index has a high correlation degree with plasma bilirubin concentration (0, 92).
Technical Specification :
Notes :