Technical Details
| Ambient operating temperature range: | 10°C to 50°C. |
|---|---|
| Operating Altitude: | -557 ft. to +16,000 ft / -170m to +4877m. |
| Monitoring range: | 18% to 100%. |
| Sensor used: | Galvanic sensor. |
| Transport/Storage Temperature: | -13°F to +131°F (-25°C to +55°C) . |
| Accuracy: | +/- 1 %. |
| Ambient working Humidity: | 15% to 95% non-condensing. |
| Dimensions: | (17cm x 6cm x 13cm). |
| Weight: | 0.4 Kg. |
| Power: | 230V AC (5W). |
| Equipment Classification: | Class 2 Device, Continuous Operation. |
| Water protection: | Not protected . |
| Alarm: | Audio Visual. |
| Alarm range: | Default low = 18, High = 75. User selectable low = 15 TO 90. User selectable High = 21 TO 100. |
| Display: | LCD. |
| Battery Backup (Optional): | 8 Hrs . |
Note: company believes in continuous up gradation hence specifications may change.
Features :
Technical Details
| Pneumatic Data | |
| Maximum input Pressure: | 100 PSI (6.89 bar). |
| Storage | |
| Atmospheric Pressure: | 780hPa < p < 1060hPa. |
| Physical Data | |
| Gas inlet connector: | 8 mm male PU fitting. |
| Dimensions in inches: | 19.7 W x 9.2 H x 6D (cm) . |
| Weight: | 0.25Kg. ( without battery). |
| Electrical Data | |
| Power cord: | 2 Mtr. |
| Power protection: | Fuse used. |
| Power requirements: | 230VAC +10% or -10% 50Hz. |
| Power consumption: | 5 watts. |
| Data displayed on LCD | |
| Gas pressure : | Digits shown in PSI . |
| Alarm : | lower or upper respective setting will blink And audio tone will be sounded. |
| Key: | - |
| Upper limits: | One key provided. |
| Lower limit: | One key provided.. |
| Environmental Data | |
| Ambient Operating Temperature: | 10 c to 45 c Humidity below 90% 1c to 60 c. |
| 8 Hrs Battery backup: | Optional. |
Note: company believes in continuous up gradation hence specifications may change
Features:
Technical Details
| Ambient operating temperature range: | 10°C to 50°C. |
|---|---|
| Operating Altitude: | -557 ft. to +16,000 ft / -170m to +4877m. |
| Patient pressure Range: | 26.7 °C to 43.3 °C. |
| Temperature Predict Time*: | (Skin) 10 seconds. |
| Transport/Storage Temperature: | -13°F to +131°F (-25°C to +55°C). |
| Accuracy: | +/- 0.1°C. |
| Humidity: | 15% to 95% non-condensing. |
| Dimensions: | (17cm x 6cm x 13cm). |
| Weight: | 630 grams. |
| Power: | 230V AC (10W) |
| Equipment Classification: | Class 2 Device, Continuous Operation |
| Water protection: | Not protected |
| Alarm: | Audio Visual |
| Alarm range: | Default low = 35, High = 38. User selectable low = 28 TO 37. User selectable High = 37 TO 50. |
| Display: | LCD. |
| Battery Backup 8hrs: | (Optional) |
* Predict time depends on probe placement and patient condition. Predict times do not include tissue contact-detection time or time needed to place the probe into the measurement site.
Features:
Technical Details
| Ambient operating temperature range: | 10°C to 50°C. |
|---|---|
| Operating Altitude: | -557 ft. to +16,000 ft / -170m to +4877m. |
| Patient pressure Range: | 0 to 100 cmH2O. |
| Sample Pressure inlet port size: | 5 mm male connector. |
| Transport/Storage Temperature: | -13°F to +131°F (-25°C to +55°C). |
| Accuracy: | +/- 1 cmH2O. |
| Humidity: | 15% to 95% non-condensing. |
| Dimensions: | (17cm x 6cm x 13cm). |
| Weight: | 0.85 Kg. |
| Power: | 230V AC (10W) |
| Equipment Classification: | Class 2 Device, Continuous Operation |
| Water protection: | Not protected |
| Alarm: | Audio Visual |
| Alarm range: | default low = 0, High = 35. User selectable low = 0 TO 20. User selectable High = 5 TO 90. |
| Display: | LCD. |
| Battery Backup (Optional): | 8 Hrs |