We offer a complete product range of Digital Storage Oscilloscope and Analogue Oscilloscope

Digital Storage Oscilloscope

  • echnical Parameters Model/Index
  • DSO-5100 Bandwidth
  • 100MHZ Channel
  • 2 channels+1 ext trig Real Time Sampling
  • 500MSa/s Equivalent Sampling Rate
  • 50GSa/s Memory Depth
  • 32k Rise time
  • <3.5ns Input Impedance
  • 1MΩ||17Pf Time Base range
  • 2.5ns/div-50s/div Scan- 100ms-50s/div
  • Vertical Sensitivity 2mv-5v/div
  • Vertical Resolution 8bit
  • Display 7″(178mm) color TFT(480*234) LCDv

ADigital Storage Oscilloscopeis anoscilloscopewhich stores and analyses the signaldigitallyrather than usinganaloguetechniques. It is now the most common type of oscilloscope in use because of the advanced trigger, storage, display and measurement features which it typically provides.

Features and Benefits:

Up to 100MHz Bandwidth 1GSa/s sample rate7TFT-LCD display, 8*18 gridsChannels: 2CH+1EXTMemory Depth: 40Kpts, 5Kpts/CH6 digits hardware frequency counter, real time counting displaySupport SCPI programming command controlInterface: USB Device, USB Host, RS-232, Pass/FailUnique digital filter and data recorder functionEmbedded 12 languages, online help, one key storing and one keyprinting

  • The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 50GSa/s.
  • Memory Depth: 32Kpts, 5Kpts/CH
  • Trigger types: Edge, Pulse Width, Video, Slope, Alternative
  • Unique Digital Filter function and Waveform recorder function
  • Support Pass/Fail function.
  • Thirty two parameters Auto measure function.
  • Save/recall types: Setups, Waveforms, CSV file, Picture.
  • Support Multilingual On-line help system
  • Waveform Intensity and Grid Brightness can be adjusted.
  • Support twelve types Language
  • Standard Configuration Port:
View Complete Details

Analogue Oscilloscope

An oscilloscope is easily the most useful instrument available for testing circuits because it allows you toseethe signals at different points in the circuit. The best way of investigating an electronic system is to monitor signals at the input and output of each system block, checking that each block is operating as expected and is correctly linked to the next. With a little practice, you will be able to find and correct faults quickly and accurately

Technical Data OS- 5010C
CRT
Type 3″ round
Display area  8 x 10DIV (1DIV=6mm)
Lightering color Green
Potential 1.3kV
VERTICAL SYSTEM
Sensitivity 5mV / DIV~5V / DIV ±3%
Width of band (-3dB) DC: 0~10MHz
AC: 10Hz~10MHz
Max. Input Voltage 400V (DC + ACpeak)
Input Coupling AC, DC , GND
Input Impedance 1MΩ±3% 30pF±5pF
Trimming ratio 2.5 : 1
HORIZONTAL SYSTEM
Sweep time  0.1S / DIV ~ 0.1μS / DIV ±3%
Trimming ratio 2.5:1
TRIGGER SYSTEM
Mode AUTO, NORM, TV
Source INT, LINE, EXT
 Polarity “+” or “-“
Trigger sensitivity INT: 1DIV, EXT: 0.3V, TV: 2 DIV
External trigger input Input impedance: 1MΩ±3% 25pF±5pF
Max. input voltage: 160V (DC+ACpeak)
X-Y OPERATION
Sensitivity X: 0.5V / DIV Y: 5mV / DIV ~ 5V / DIV
Width of band (-3dB) DC: 0-1MHz AC: 10Hz – 1MHz
Phase difference ≤3 (DC ~ 50kHz)
CALIBERATION
Source 1kHz±2% 0.5Vp-p±2% square wave
POWER SOURCE 110~127 VAC±10%, 220~240VAC±10% 50Hz±2Hz, 60Hz±2Hz