Our Products
Mycron Air Tech presents its biological safety cabinet are made of MS/GI powder coated and stainless steel 304 / 316 grades with international quality standard components. A biological safety cabinet also called as Bio Safety Cabinet (BSC). It is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined bio-safety level. Several different types of BSC exist.
Class IClass I cabinets provide personnel and environmental protection. These BSCs are commonly used to enclose specific equipment or procedures that potentially generate aerosols. BSCs of this class are either ducted (connected to the building exhaust system) or without ducted (recirculation filtered exhaust back into the laboratory).
Class IIClass II cabinets provide both kinds of protection of the samples and of the environment since makeup air is also HEPA-filtered. There are four types: Type A1, A2 and Type B1, B2.
Class IIIThe Class III cabinet, generally only installed in maximum containment laboratories. It is specifically designed for work with BSL-4 pathogenic agents, providing maximum protection. The enclosure is gas-tight, and all materials enter and leave through a dunk tank or double-door Passbox. Gloves attached to the front prevent direct contact with hazardous materials. These cabinets are sometimes called glove box.
Mycron Air Tech presents its Air showers are made of MS/GI powder coated and stainless steel 304 / 316 grades with international quality standard components. Air showers are specialized enclosed antechambers which are incorporated as entryways of clean rooms and other controlled environments to reduce particle contamination.
Air showers utilize high-pressure, HEPA filtered air to remove dust, fibrous lint and other contaminants from personnel or object surfaces. The forceful "cleansing" of surfaces prior to entering clean environments reduces the number of airborne particulates introduced.
Air showers are generally constructed from clean room compatible steel or plastic materials and feature electronically powered blowers, filters and high-pressure jet nozzles. The latter being incorporated into the walls and ceiling of the chamber.
Air at velocities of 3, 000 to 7, 000 feet-per-minute (FPM), continuously streams from the jet nozzles for 20-40 seconds effectively removing loose particulate matter. Personnel inside the enclosure will lift their arms and turn their bodies for uniform exposure to the air streams.
A procedure usually specified in protocol. Air currents from the jets create shearing and flapping forces which lift and remove contaminants from both flat surfaces and the creases of garments. HEPA filtration within the air shower is capable of removing 99.97% of particles greater than 0.3m diameter.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in mm (LxBxH) | 900x1000x2100 (1 meter), 900x2000x2100(2 meter) up to 10 meters |
2 | Material of Construction | MS/GI Power coated, SS 304/316 |
3 | MOC of Working Area | MS/GI Power coated, SS 304/317 |
4 | HEPA Filter w.r.t Working Area in mm (LxBxH) | 0.3 µ Mini Plate 610x915x75 |
5 | Pre Filter | 10 µ 800x400x50 |
6 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
7 | Nozzle | Yes, Rotatable type |
8 | No of Nozzles | 14 – 17 per meter |
9 | Shower duration | 0-60 secs Adjustable |
10 | Protections | Electro Magnet Inter locking for both doors, Emergency Exit push button, Separate Thermal relay for Motor protection |
11 | Door | MS/GI Power coated, SS 304/317 with Static Handle and Door closer |
12 | Illumination | Yes, LED |
13 | Power Required | Three Phase 415V/50 Hz |
14 | Total Power Consumption | 5KW |
15 | Noise level | 75 db +/- 5 db |
16 | Vibration Level | < 2.5 µm (0.000025m) |
Mycron Air Tech presents its Clean Room pass box equipment, fabricated with MS/GI powder coated and stainless steel 304 / 316 grades are capable of eradicating pollutants completely from the air. Such pass box exists in Static and Dynamic configurations.
Static Pass BoxThese static pass boxes are installed in manufacturing areas and filter the incoming air in order to keep the air free from dust and other contaminants. With UV light along with hour meter, Fluorescent light, buzzer indicator to know the material is kept inside and indicating lamp, these static pass boxes provide excellent working performance in the clean room unit.
An interlock guard system controls the inlet and the outlet of pass box not be opened at the same time, in order to prevent the cross contamination.
Dynamic Pass BoxThe Dynamic Pass Box equipments are made of MS/GI powder coated and stainless steel 304 / 316 grades with international quality standard components including mechanically or electrically interlocked doors and UV light.
These dynamic pass box equipment are equipped with suction filter made of stainless steel with 95% down to 0.3 efficiency and supply filter made of aluminum with 99.999% down to 0.3 . An interlock guard system controls the inlet and the outlet of pass box not be opened at the same time, in order to prevent the cross contamination.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 2x2x2 , 3x3x2 and as per Req. |
2 | Material of Construction | SS 304/316 |
3 | MOC of Working Area | SS 304/317 |
4 | HEPA Filter w.r.t Working Area in mm (LxBxH) | 0.3 µ Mini Plate as per Req. (Dynamic Pass box only) |
5 | Pre Filter | 10 µ as per Req. |
6 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
7 | Protections | Electro Magnet Inter locking for both doors, push button and Door position indicator |
8 | Door | SS 304/317 with Static Handles |
9 | Illumination | Yes, LED |
10 | UV Lamb | Yes |
11 | UV Hour meter | Yes |
12 | Pressure Gauge | Yes (Dynamic Pass box only) |
13 | Power Required | Three Phase 230V/50 Hz |
14 | Total Power Consumption | 1KW |
15 | Noise level | 65 db +/- 5 db |
16 | Vibration Level | < 2.5 µm (0.000025m) |
Mycron Air Tech presents a Fume Hood fabricated with MS/GI powder coated, stainless steel 304 / 316 grade and plywood. A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.
Two main types exist, ducted and recirculation (ductless). The principle is the same for both types are air drawn in from the front side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room.
This is used to protect the user from inhaling toxic gases and the secondary functions of these devices may include explosion protection, spill containment, and other functions necessary to the work being done within the device.
Fume hoods are generally set back against the walls and are often fitted with in fills above, to cover up the exhaust ductwork.
Because of their recessed shape they are generally poorly illuminated by general room lighting, so many have internal lights with vapor-proof covers. The front is a sash window, usually in glass, able to move up and down on a counterbalance mechanism.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 2x2x2 , 3x2x2, 4x2x2, 6x2x2 |
2 | Material of Construction | MS/GI Power coated, SS 304/316 |
3 | MOC of Working Area | FRP Coating |
4 | MOC of Working Table | Granite Stone |
5 | Storage Cabinet | Yes, as per req. |
6 | Motor & Blower | Dynamically balanced Motor with Aluminum Blower |
7 | Door | MS/GI Power coated, SS 304/316 with 5mm Clear Glass Sliding Door |
8 | Sink with Tap | Yes, as per Req. |
9 | Gas Supply Provision | Yes |
10 | Illumination | Yes, LED |
11 | Power Socket | Yes, 5A |
12 | Duct | Yes, Up to 10 feet with one Elbow |
13 | Power Required | Single Phase 230V/50 Hz |
14 | Total Power Consumption | 2KW |
15 | Noise level | 75 db +/- 5 db |
16 | Vibration Level | < 2.5 µm (0.000025m) |
Mycron Air Tech presents a Laminar Air flow cabinet fabricated with MS/GI powder coated, stainless steel 304 / 316 grade and plywood box. It is a carefully enclosed bench designed to prevent contamination of semiconductor wafers, biological samples, or any particle sensitive materials.
Air is drawn through a HEPA filter and blown in a very smooth, laminar flow towards the user. The cabinet is usually made of Wood, MS/GI Powder Coated and stainless steel (grade 304/316).
Such hoods exist in horizontal, vertical and ceiling suspended configurations. Laminar flow cabinets may have a UV Lamp to sterilize the interior and contents before usage to prevent contamination of experiment.
UV lamps are usually kept on for 15 minutes to sterilize the interior and no contact is to be made with a laminar flow hood during this time. During this time, scientists normally prepare other materials to maximize efficiency.
It is important to switch this light off during use, to limit exposure to skin and eyes as stray ultraviolet light emissions can cause cancer and cataracts.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 2x2x2 , 3x2x2, 4x2x2, 6x2x2 |
2 | Material of Construction | MS/GI Power coated, SS 304/316 |
3 | MOC of Working Area | SS 304/316 |
4 | HEPA Filter w.r.t Working Area in mm (LxBxH) | 0.3 µ Mini Plate 610x610x75, 915x610x75, 1220x610x75 |
5 | Pre Filter | 10 µ as per Req |
6 | Storage Cabinet | Yes, as per Req |
7 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
8 | Door | 5mm Acrylic Sliding/Foldable Door |
9 | Gas Supply Provision | Yes |
10 | Illumination | Yes, LED |
11 | UV Lamb | Yes |
12 | UV Hour meter | Yes |
13 | Power Socket | Yes, 5A |
14 | Pressure Gauge/ mano meter | Yes |
15 | Power Required | Single Phase 230V/50 Hz |
16 | Total Power Consumption | 2KW |
17 | Noise level | 70 db +/- 5 db |
18 | Vibration Level | < 2.5 µm (0.000025m) |
Mycron Air Tech make Powder containment booths are used to control the hazardous emissions of powders, dust or vapors during powder dispensing, product sampling, or bag dispensing, etc., without risk to the operator or environment.The downdraught prevents airborne dusts caused by weighing and dispensing operations rising into the operator's breathing zone. The air forced downwards is extracted at low level into the booth's filtration system where dust particles are contained at each level of filtration prior to being re-circulated back into the booths air stream.
The Powder Dispensing/ Sampling Booths are designed to give mixed air flow stream for product, operator and environmental protection and used to control the hazardous emissions of dust powder during powder dispensing / sampling process. 0.3 micron downward air stream deflects air-borne dust away from the operator breathing zone which is caused in handling operation.
Dust particle available is being filtered at three levels of filtration prior to being circulated back to the booths air stream. For filling, refilling, weighing & sampling of Raw material & Components.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 2x2x7 , 3x3x7, 4x4x7, 6x4x7 |
2 | Material of Construction | SS 304/316 |
3 | MOC of Working Area | SS 304/317 |
4 | HEPA Filter w.r.t Working Area in mm (LxBxH) | 0.3 µ Mini Plate as per Req. |
5 | Pre Filter | 10 µ as per Req. |
6 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
7 | Illumination | Yes, LED |
8 | Power Socket | Yes, 16A |
9 | Power Required | Single Phase 230V/50 Hz |
10 | Total Power Consumption | 2 – 5KW as per Req. |
11 | Noise level | 75 db +/- 5 db |
12 | Vibration Level | < 2.5 µm (0.000025m) |
Mycron Air Tech presents it is an Air curtain. It is a continuous broad stream of air circulated across a doorway of a conditioned space. It reduces penetration of insects and unconditioned air into a conditioned space by forcing an air stream over the entire entrance. The air stream layer moves with a velocity and angle such that any air that tries to penetrate the curtain is entrained. Air curtain effectiveness in preventing infiltration through an entrance generally ranges from 60 to 80%.Such Air Curtains are available size in 2, 3, 4 and 5 feets.
Air doors are often used where doors are required to stay open for operational purposes, such as at loading docks and vehicle entrances. They can be used to help keep flying insects out by creating forceful turbulence, or help keep out outside air, thus reducing infiltration through the opening. Cold drafts can be avoided by mixing in warm air heated by the air door. Heated air doors are commonly used when supplemental heat is needed for a space, and to reduce the wind chill factor inside the opening, in colder climates.
Further applications include customer entryways, airplane hangars, cargo doors, drive through windows, restaurant doors, or shipping receiving doors. Non-heated air curtains are often used in conjunction with cold storage and refrigerated rooms.
PVC Strip CurtainsThe PVC Strip Curtains are made from specially developed PVC material, which offers a cost effective and a simple way to control temperature, humidity and prevent the ingress of dust and insects.The plastic strip curtain doors are ideal for maintaining an ambient temperature for your warehouse or cold store, keeping out unwanted pests, restricting the movement of air pollutants or isolating noisy machinery. The strips of these doors are made of transparent or colored plastic in full or partial overlap, these strips can create real partition walls suitable to divide rooms and sheds.
Pharmaceutical Industries Manufacturing Plants Hotels & Kitchen Area Cold Storage Dairy Industry Freeze Zones Packaging Industries Processing of Agricultural Products Factories Warehouses Health Care Facilities Food Processing Zones.
HEPA air filters are made from very tiny glass fibers that are made into a tightly woven paper. This creates a filter consisting of a multitude of very small sieves that can capture extremely small particles, including some biological agents. Once trapped, contaminates and particles are not able to flow back into circulation, due to the highly absorbent pores of the HEPA air filter.
High efficiency particulate air (HEPA) is originally called high-efficiency particulate absorber but also sometimes called high-efficiency particulate arresting or high-efficiency particulate arrestance, is a type of air filter. Filters meeting the HEPA standard have many applications, including use in medical facilities, automobiles, aircraft and homes. The filter must satisfy certain standards of efficiency such as those set by the United States Department of Energy (DOE).
To qualify as HEPA by US government standards, an air filter must remove (from the air that passes through) 99.97% of particles that have a size of 0.3 .
HEPA filters are composed of a mat of randomly arranged fibers. The fibers are typically composed of fiberglass and possess diameters between 0.5 and 2.0 micrometers. Key factors affecting its functions are fiber diameter, filter thickness, and face velocity. The air space between HEPA filter fibers is typically much greater than 0.3 .
HEPA Filters are available in various sizes as per the req.
Carbon FiltersWhat is Activated Carbon FilterActivated carbon air filters consist of a vast system of pores of molecular size. These pores are highly adsorbent, forming a strong chemical bond/attraction to odorous, gaseous, and liquid contaminates, especially organic chemicals/compounds.
Activated Carbon Filter Facts
S.No | Features | Specifications |
---|---|---|
1 | Available Filter types | Box and Blanch |
2 | Available Sizes in feet’s (LxB) for Mini Plate Filters H=75mm | 1×1,2×2,3×2,4×2, 1.5×1.5,2×1.5,3×1.5,4×1.5 |
3 | Available Sizes in feet’s (LxB) for D-Plate Filters H=100mm | 1×1,2×2,3×2,4×2, 1.5×1.5,2×1.5,3×1.5,4×1.6 |
4 | Efficiency of media | 99.99% |
5 | Particle Allowed range | 0.3 µ |
6 | Material of Construction | Aluminum, MS Powder Coated, SS 304 |
7 | Protection | Both sides should be covered by metallic powder coated grill |
8 | Other than standard size filters | Yes, as per the Req. |
S.No | Features | Specifications |
---|---|---|
1 | Available Filter types | Box and Blanch |
2 | Available Sizes in mm (LxB) and H=50,75,mm and as per Req. | 300×400, 600×400, 800×400, 600×600 as per Req. |
3 | Efficiency of media | 99.99% |
4 | Particle Allowed range | 5 µ and 10 µ |
5 | Material of Construction | Aluminum, MS Powder Coated, SS 304 |
6 | Protection | Front sides should be covered by Aluminum grill |
7 | Other than standard size filters | Yes, as per the Req. |
Mycron Air Tech Garment Storage Cabinets are manufactured for highest degree of safety for both the users and for the products high efficient HEPA filters are found in these cabinets. These cabinets are equipped with a blower, UV and a HEPA filter in a fully contained enclosure constructed of powder-coated steel sheets, which will not shed particles or contaminate the environment of your clean room.
They provide a solution for storing your clean room garments in a visible and organized manner, while at the same time removing particulate contamination from your garments as they are stored and removed.
Safety LockersMycron Air Tech Safety Locker Cabinets consists of wall mount, freestanding, countertop, stackable and mini models designed to provide safe storage for flammables, corrosive liquids, tools and/or valuables. These cabinets feature a durable, SS304 metal construction, lead-free powder coat paint finish, large warning labels for clear identification of contents inside and meet a variety of regulations.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes in feet’s (LxBxH) | 2x1x2,3x1x3,4x1x4,6x1x6 as per Req. |
2 | Material of Construction | MS Powder Coated, SS 304/316 |
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 2x1x5 , 3x1x5, 4x1x5 as per Req. |
2 | Material of Construction | MS/GI Power coated, SS 304/316 |
3 | HEPA Filter | 0.3 µ Mini Plate, as per Req. |
4 | Pre Filter | 10 µ as per Req. |
5 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
6 | Door | 5mm Acrylic/Glass Door |
7 | Illumination | Yes, LED |
8 | UV Lamb | Yes |
9 | UV Hour meter | Yes |
10 | Pressure Gauge | Yes |
11 | Power Required | Single Phase 230V/50 Hz |
12 | Total Power Consumption | 2KW |
13 | Noise level | 70 db +/- 5 db |
14 | Vibration Level | < 2.5 µm (0.000025m) |
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes in feet’s (LxBxH) | 2x2x2,3x2x2,4x2x2,6x2x2 as per Req. |
2 | Material of Construction | SS 304/316 |
Mycron Air tech presents it is a Modular clean room tent to provide outstanding performance as well as aesthetic appeal. Clean room tents are composed of walls of heavy plastic sheeting supported by a strong metal frame. This superior construction provides the flexibility to easily assemble, reconfigure and move clean room tents.
Clean room tents are available in both vertical and horizontal air flow configurations. All clean room tents from Clean Air Products are equipped with HEPA filtration systems to provide either positive or negative air pressure. Soft wall clean room tents are available from Class 100, 000 to Class 10. Clean room tents are a low-cost option for industries seeking high-performance particulate controlled environments.
The Clean Room Tent is a designed and constructed room in which the air supply, air distribution, filtration of air supply, materials of construction, and operating procedures, are regulated to control airborne particle concentrations to meet appropriate cleanliness levels.
S.No | Features | Specifications |
---|---|---|
1 | Available Sizes w.r.t Working Area in feet’s (LxBxH) | 6x6x6 , 8x8x8, 10x10x10 as per Req. |
2 | Material of Construction | MS/GI Power coated, SS 304/316 |
3 | HEPA Filter | 0.3 µ Mini Plate, as per Req. |
4 | Pre Filter | 10 µ as per Req. |
5 | Motor & Blower | Dynamically balanced Motor with Aluminum/PVC Blower |
6 | Door | PVC Strip Curtains |
7 | Illumination | Yes, LED |
8 | Pressure Gauge | Yes |
9 | Power Required | Single Phase 230V/50 Hz |
10 | Total Power Consumption | 2-5 KW |
11 | Noise level | 70 db +/- 5 db |
12 | Vibration Level | < 2.5 µm (0.000025m) |