Our Products
Additional Information:
Payment Terms : T/T
Packaging Details : Standard Corrugated Box
Delivery Time : 1 week
Additional Information:
Payment Terms : T/T
Packaging Details : Standard Corrugated Box.
Delivery Time : 1 week
Additional Information:
Payment Terms : T/T
Packaging Details : Standard Corrugated Box.
Delivery Time : 1 week
Laboratory Instrument
MICRO CONTROLLER pH METER NIG 334
Technical Specifications
Range:0 to 14 pH mV ;Range:-1999mV to+ 1999mV, pH:Resolution: 0.01 pH, mV:Resolution: 1mV, pH:Accuracy: 0.01 pH 1 digit, mV:Accuracy: 0.1% of range, Slope Adjustment: 80% to 120% 1 digit , Calibration:mV: 2 point manual, Temp. Compensation: 0-100C by default 100%, automatic with temperature probe / manual with
keys.Auto Buffer Recognition: 4.00 pH, 7.00 pH, 9.20pH
Calibration: 2/3 point auto & manual, Real time display:24 Hour
Temperature: Range: - 50C to +200C mode with date, Resolution: 0.1CInterface: Rs232, Centronics & computer
Accuracy:0.1%+1 digit of rangePrint format:All Data & Date, wise , Calibration: Two point manualDigital output :Serial RS 232, , Parallel Centronics, Sensor: Pt100 probe (Programmable), Data Entry: By six soft touchFunctions:pH OR mV &
keys With audible sound Temp. simultaneously, Storage: 1000 samplesDisplay:16 Character x 2 lines Alpha numeric
Power Supply:230 V 10%, 50 Hz AC, Error Indication:ERROR, ORP ERROR, CALERROR & T ERROR, Dimensions:(L x B x H) 235 x 245 x 80 mm, Weight: 3.00 Kgs, Standard Accessories:pH Electrode, Electrode stand, Dust Cover, Instruction manual, Buffer solutions, Temperature probe.
Function :pH & temperature OR mV & temp. OR Conductivity & temp. OR TDS & temp. OR Salinity & temp simultaneouslyDisplay :16 character x 2 lines AlphanumericBL LCDPower supply:230 V 10% 50 Hz AC
pH
Range :0 to 14 pH , Resolution:0.01 pH, Accuracy : 0.01 pH 1 digit, Slope adjustment:80% to 120%By default 100%, Temp .compensation:0 to 100 CAuto with temp probe / Manual withkeys .Auto buffer recognition :4.00 pH, 7.00 pH, 9.20 pH, Calibration :Auto & manual, 3 point & 2 point (Programmable)
Conductivity-TDS-SAL
Range:Conductivity0.00 uS/cm to 1000 mS in 6- Auto ranges, TDS:0.00ppmto 200ppt in 6- Auto ranges , SAL:0.0pptto50ppt Auto ranging, Resolution:Conductivity0.01/.1/1 u S/ m S as per range, TDS:0.01/.1/1 ppm/ ppt as per range, SAL:0.1 ppt, Accuracy : 0.5%of range 1 digit, TDS Factor :0.50(By default) & adjustable manually, SAL Factor :0.75(By default) & adjustable manually, Cell const. adjustment :Digital 0.05 to 2.000By default 1.000, Temp. compensation :0 to 70 C Auto with temp. probe/Manual withkeys, Temp. Coefficient adj. : 0.00% to 4.00% adjustable. By default 2.00%, Reference Temp. :20 Degree C & 25 Degree C, Mode of Calibration:By Value & By Measurement
Temperature
Range:-20.0 C to 200 CResolution :0.1 C , Accuracy : 0.1% of range 1 digit, Calibration :two point manual, Sensors : Pt100 probe, Data entry: By six soft touch keys with audible sound , Storage:1000 samples, Real time display:24 Hour, Print format:All Data& Date Wise(Programmable), Digital output:Serial RS-232 , Parallel mode with Date, Interface: RS-232, Centronics & computer
Print format:All Data& Date Wise(Programmable), Digital output:Serial RS-232 , Parallel Centronics (Programmable), Error Indication :pH ERROR, ORP ERROR, CAL ERROR & T-ERROR,
Accessories:pHElectrode , Cond /TDS Cell, Temp. Probe, DustCover, Instruction Manual.
Functions: pH & Temperature simultaneously.Display:16characters x 2 lines, alphanumeric LCD self diagnostic type.Power Supply:9 V battery/ AC adapter (Optional).Range:0 to14 pH.Resolution: 0.01 pH.Accuracy: 0.01 pH 1 digit.Slope Adjustment: 80% to 120% by default 100%.Temp. Compensation :0 to100C, Automatic with Pt100, and Manual by soft keys.Auto Buffer recognition: 4.00 pH, 7.00 pH, 9.20pH.Calibration: Auto and manual .Range: -50 C to +200C.Resolution: 0.1C.Accuracy: 0.1% of range 1 digit.Calibration: Two point manual.Sensor: Pt100probe.Data Entry: By soft touch keys.Weight:500 gms.Dimensions(L x B x H): 150 x 85 x40 mm.Accessories: pH Electrode, Instructionmanual, Buffer Solutions, Temp. probe.
Range:0.0 to 14.0 pH.Resolution:0.1 pHAccuracy :(@20C/68F)0.1 pH .Calibration:manual, 1
Point .Battery Type / Life:3 x 1.5V /approx. 150 hours .Environment:0 to 50C (32 to122F); RH max 95%.Dimensions150 x 30 x 21 mm (5.9 x 1.2 x 0.8'').Weight:70 g (2.5 oz.)
TECHNICAL SPECIFICATIONS
Conductivity:
Range: 0.00 u S/cm to 1000 mS /cm, Auto ranging.Resolution: 0.01uS on the lowest rangeAccuracy:0.5% of range 1 digit.Temp.Compensation: 0-70C, Auto with temp. probe/ manual with keys.Temp. coefficient
adjustment: 0.00% to 4.00% adjustable by default 2.000%.Cell Constant adjustment: Digital 0.05 to 2.000 by default 1.000.Reference Temp.:20C & 25C.Measuring Frequency:100Hz and 1 KHz , auto selection.Calibration: Manual.Mode ofcalibration: By Value & by Measurement.
Temperature:Range: -200 C to +200 C.Resolution:0.1 C.Accuracy: 0.1% of range 1 digit.Calibration: Two pointmanual.Sensor: PT-100 probe.Data Entry: By soft touch keys with audible sound.Data storage: 1000 samples.Real timedisplay: 24 Hour mode with Date.Interface: RS-232, Centronics & computer.Print format:All Data, Date Wise.Digital output:Serial RS 232, Parallel Centronics.Functions:Conductivity & Temp. Simultaneously.Display:16 Characters x 2 lines Alphanumeric BLCD.Power Supply: 230 V 10%, 50 Hz AC.Dimensions: (Lx B x H): 235 x 245 x 80 mmWeight: 3 Kgs.Accessories: Conductivity cell, Dust Cover, Temp. probe, Instruction manual.
SPECIFICATIONS:
TDS Meter
HI 96301 (DIST 1) HI 96302 (DIST 2),
Range:1990 ppm 10000 ppm
Resolution:10 ppm 100 ppm
Accuracy2% F.S.2% F.S.(@20C/68F):
EC Meter
HI 96303(DIST 3), HI 96304 (DIST 4)
Range:1990 s/cm19900S/cm
Resolution:10S/cm100S/cm
Accuracy2% F.S.2%F.S.(@20C/68F):
Calibration:manual, 1 point, through trimmerTemperature CompensationAutomatic, 5 to 50C (41 to 122F)Battery Type / Life(4) 1.5V / approx. 150 hours of continuoususeEnvironment0 to 50C (32 to 122F); RH max 95%Dimensions:150 x 30 x 21 mm (5.9 x 1.2 x 0.8'')Weight 70 g (2.5 oz.)
Range: 0 to 20, 000 mg/litre.Resolution: 10 mg/ litre.Accuracy(F.S): 1% 1 digit, Display: 3 1/2digit LCD.Dimensions(L x B x H): 85 x 160 x 30 mm.Power Supply: 9 VBattery, AC adapter (Optional).Ambient Temp.: 10 C to 50 C.Weight:500 gms.Accessories: complete with TDS, Cell, KCL Solution , Instruction manual.
Technical Specifications
Function:Turbidity & temp. simultaneously, Display:16 character x 2 lines AlphanumericBL LCD, Power supply:230 V 10% 50 Hz AC,
Turbidity:
Range:0-1000 NTU in Two Ranges, : .1 NTU in lowest Range, Accuracy: 3% FS1-digit, Range Selection:Automatic, Detector: Photodiode/Photocell , Sample System: 30 mm Clear Glass test tub , Calibration: Manual , Light Source: 6V Tungsten Lamp , Display format: Temp. and parameter , Simultaneously
Real Time Display: 24 Hour Mode With Date &Time,
Temperature:
Range: -20.0C to 200C, Resolution: 0.1 C, Accuracy: 0.1% of range 1 digit, Calibration:two point manual
Sensors : Pt100 probe, Data entry: By six soft touch keys with audible sound , Storage:1000 samples, Real time display: 24 Hour mode with Date , Interface: RS-232, Centronics & computerPrint format: All Data& Date Wise(Programmable), Digital output: Serial RS-232Parallel Centronics (Programmable)
Accessories:Instruction Manual, test tube, Temp .Probe.
Technical Specifications
The digital count on the display can be reset manually anytime by pressing the RESET key provided. An integral magnifying glass provided for easier counting of small colonies.Digital Display: 4 digits.Display Read Out: 0 - 9999Max. Counts: 9999.Petri Dish Size: 110 mm.Magnification: x 1.7, Dimensions: 274 (L) x320 (B) x 167 (H)mm, Weight:3 Kg. Approx .Power Supply: 220V 10%, 50 Hz AC, Accessories: Marking Pen, Magnifier Lens
Additional Information:
Payment Terms : T/T
Packaging Details : Standard Corrugated Box.
Delivery Time : 1 week
Range:pH: 0 - 14 pH.mV: 0 to 1999mV, Resolution:pH:0.01pH, mV: 1 mV.Accuracy: pH: 0.01pH 1 digit, mV: 1mV 1 digit.Slope Correction: 80% to 120% .Temp.Compensation: 0-100C Manual & (Automatic optional).Indication: 3 digit LED (12.5 mmhigh).Power Supply: 230 V 10%, 50 Hz AC.Input Resistance: 10^12 ohms.Ambient Temp.: 10 C to 50 C.Dimensions(L x B x H): 210 x 190 x 90 mm.Weight: 3.0 Kgs.Accessories: pHElectrode, Electrode stand, Dust Cover, Instruction manual, buffersolutions.
Technical Specifications
Range:10 u mho to 1000 mmho In 5 ranges.Resolution:0.01 umho.Accuracy(F.S): 0.5% 1 digit.Cell ConstantCompensation:Adjustable.Display:3 1/2 digit LED.Input Frequency:1000 Hz, Temp Comp.:Manual & Automatic(optional).Dimensions(L x B x H): 210 x 190 x90 mm.Power Supply: 230 V 10% 50 Hz AC.Ambient Temp.: 10 C to 50 C.Weight:3.00 Kgs.Accessories:Conductivity cell, KCL solution, Dust cover, Instruction manual.
Range: 10 ppm to 1000 ppt in 5 ranges.Resolution:0.01 ppm in lowest range.Accuracy(F.S.): 1% 1 digit.Cell Constant Compensation:Adjustable (0.5 to1.5).Display: 3 1/2 digit LED.Dimensions(L x B x H): 210 x 190 x90 mm.Power Supply: 230 V 10%50 Hz, AC.Ambient Temp.: 10 C to50 C.Weight: 3.00 Kgs.Accessories: TDS cell, KCL solution, Dust Cover, Instruction manual.
Additional Information:
Payment Terms : T/T
Packaging Details : Standard Corrugated Box.
Delivery Time : 1 week
Technical Specifications
Measuring Method: Cyanmethemoglobin, Measuring Range: 0-40 gm /dl of Hb, Sample Volume: 1 ml