Post Buy Requirement
NA
Alwar, Rajasthan, India
Add Review

Electrical Cables & Wires #5440091

Flexible Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
ZHLS inner sheath, black
ZHLS outer sheath, black

Standard References

  • IEC 60502-1

Special Features

  • Low bend diameter
  • Flexible
  • Execllent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity
  • Improved mechanical strength and abrasion resistance

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations
  • Suitable for power applications
  • Suitable for direct burial

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage0.6/1.0kV
  • Test Voltage3000V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

General Halogen Free

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
ZHLS outer sheath, grey

Standard References

  • BS EN 50525-3-11
  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Execllent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

EMI Protected Halogen Free Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
Polyester tape binded
Fine wire ATC braid
ZHLS outer sheath, grey

Standard References

  • BS EN 50525-3-11
  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Flexible
  • Space saving construction
  • Excellent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity
  • Excellent EMI protection

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations
  • For installation near electro-magnetic noise near power cables, heavy power consuming machinery and appliances
  • Measurement and control
  • Data processing and signaling

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

UN-Armoured Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :XLPE As per IS:7098/Pt.1/1988
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
    • Outer Sheath :PVC (Polyvinyl Chloride) ST2 Grade as per IS:5831

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 4.0 7 0.7 8 95 4.61 42
1 x 6.0 7 0.7 8.5 125 3.08 53
1 x 10.0 7 0.7 9.5 170 1.83 72
1 x 16.0 7 0.7 10 220 1.15 98
1 x 25.0 7 0.9 12 325 0.727 132
1 x 35.0 7 0.9 13 420 0.524 156
1 x 50.0 19 1 14 550 0.387 198
1 x 70.0 19 1.1 16 750 0.268 246
1 x 95.0 19 1.1 17.5 1010 0.193 294
1 x 120.0 37 1.2 19 1250 0.153 336
1 x 150.0 37 1.4 21.5 1550 0.124 384
1 x 185.0 37 1.6 23.5 1900 0.0991 444
1 x 240.0 61 1.7 26 2450 0.0754 510
1 x 300.0 61 1.8 28.5 3050 0.0601 570
1 x 400.0 61 2 33 4035 0.047 660
1 x 500.0 61 2.2 36 5020 0.0366 708
1 x 630.0 91 2.4 40 6250 0.0283 825
1 x 800.0 91 2.6 47 7800 0.0221 945
1 x 1000.0 91 2.8 52.6 9734 0.0176 1063
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Electrical Cables & Wires from Alwar, Rajasthan by NANGALWALA AUTO MANUFACTURING PVT. LTD.
Post Buy Requirement
NA
Alwar, Rajasthan, India
Add Review

Electrical Cables & Wires #5440091

Flexible Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
ZHLS inner sheath, black
ZHLS outer sheath, black

Standard References

  • IEC 60502-1

Special Features

  • Low bend diameter
  • Flexible
  • Execllent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity
  • Improved mechanical strength and abrasion resistance

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations
  • Suitable for power applications
  • Suitable for direct burial

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage0.6/1.0kV
  • Test Voltage3000V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

General Halogen Free

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
ZHLS outer sheath, grey

Standard References

  • BS EN 50525-3-11
  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Highly flexible
  • Space saving construction
  • Execllent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

EMI Protected Halogen Free Control Cables

Cable Structure
Class 5 bare copper conductor as per IEC 60228 and IS 8130
ZHLS Insulation
Cores twisted
Polyester tape binded
Fine wire ATC braid
ZHLS outer sheath, grey

Standard References

  • BS EN 50525-3-11
  • BS EN 50288-7

Special Features

  • Low bend diameter
  • Flexible
  • Space saving construction
  • Excellent fire retardance
  • Low halogen content
  • Excellent electrical properties
  • Good oil resistance
  • Low smoke and toxicity
  • Excellent EMI protection

Application Range

  • Industrial machinery and air conditioning systems
  • For general purpose installations in dry environment subjected to low mechanical loads
  • Areas where human or animals are present
  • Tunnels and transportation
  • Suitable for outdoor installations
  • For installation near electro-magnetic noise near power cables, heavy power consuming machinery and appliances
  • Measurement and control
  • Data processing and signaling

Technical Data

  • Temperature Range-15C to +70C
  • Nominal Voltage300/500V
  • Test Voltage1500V
  • Insulation ResistanceMin. 200Mohm-km
  • Min. Bending Radius8 x cable dia
  • Short Circuit TemperatureUpto 160C
  • Flame RetardanceAs per IEC 60332-1
View Complete Details

UN-Armoured Cables

Cable Structure

    • Class : 2Stranded Copper Wire As Per IS:8130
    • Insulated :XLPE As per IS:7098/Pt.1/1988
    • Core Identification:
      • 1 Core :Black / Red / White
      • 2 Core :Black, Red
      • 3 Core :Red, Yellow, Blue
      • 4 Core :Red, Yellow, Blue, Black
      • 5 Core :Red, Yellow, Blue, Black, Grey
      • 6 Core & above :Two adjacent cores (Counting and direction cores) in each layer, Blue & Yellow, remaining cores Grey.
    • Inner Sheath :PVC (Polyvinyl Chloride) ST2 Grade as Per IS:5831
    • Outer Sheath :PVC (Polyvinyl Chloride) ST2 Grade as per IS:5831

Core Size Stranding(Minimum No. of Strands) Nominal Thickness of Insulation(mm) Cable Diameter Approx. Weight (Kg/Km) Max DC Resistance at 20 Degree C Current Rating(amp)
SQ.MM
1 x 4.0 7 0.7 8 95 4.61 42
1 x 6.0 7 0.7 8.5 125 3.08 53
1 x 10.0 7 0.7 9.5 170 1.83 72
1 x 16.0 7 0.7 10 220 1.15 98
1 x 25.0 7 0.9 12 325 0.727 132
1 x 35.0 7 0.9 13 420 0.524 156
1 x 50.0 19 1 14 550 0.387 198
1 x 70.0 19 1.1 16 750 0.268 246
1 x 95.0 19 1.1 17.5 1010 0.193 294
1 x 120.0 37 1.2 19 1250 0.153 336
1 x 150.0 37 1.4 21.5 1550 0.124 384
1 x 185.0 37 1.6 23.5 1900 0.0991 444
1 x 240.0 61 1.7 26 2450 0.0754 510
1 x 300.0 61 1.8 28.5 3050 0.0601 570
1 x 400.0 61 2 33 4035 0.047 660
1 x 500.0 61 2.2 36 5020 0.0366 708
1 x 630.0 91 2.4 40 6250 0.0283 825
1 x 800.0 91 2.6 47 7800 0.0221 945
1 x 1000.0 91 2.8 52.6 9734 0.0176 1063