Our Products
Cable Structure
Class 6 ABC
HOFR Elastomer insulation
Special Features :
Welding Cable With International Specfication
Nominal Cross section Area of conductor | Number / Nom. Dia of Wires | Thickness of Insulation (Nominal) | Current Rating (AMP.) At Following Duty Cycle | |||||
General Purpose Compound | HOFR Compound | |||||||
Mm2 | Mm | Mm | 100% | 60% | 30% | 100% | 60% | 30% |
16 | 510/0.2 | 2 | 94 | 121 | 172 | 135 | 174 | 246 |
25 | 796/0.2 | 2 | 125 | 161 | 228 | 177 | 228 | 343 |
35 | 1114/0.2 | 2 | 156 | 201 | 285 | 221 | 285 | 403 |
50 | 707/0.3 | 2.2 | 197 | 254 | 360 | 279 | 360 | 509 |
70 | 990/0.3 | 2.4 | 248 | 320 | 453 | 352 | 454 | 643 |
95 | 1344/0.3 | 2.6 | 299 | 386 | 546 | 424 | 547 | 774 |
Cable Structure
Standard References
Special Features
Application Range
Technical Data
NOTE :
Cable Structure
Class 6 bare copper conductor as per IEC 60228 and IS 8130
TPR Insulation
Cores twisted
TPR outer sheath, grey
Standard References
Special Features
Application Range
Technical Data
Cable Structure
Standard References
Special Features
Variants :
Application Range
Technical Data
Core Size | Stranding(Minimum No. of Strands) | Nominal Thickness of Insulation(mm) | Nominal Overall Diameter(mm) | Approx. Weight (Kg/Km) | Max DC Resistance at 20 Degree C | Current Rating(amp) |
SQ.MM | ||||||
1 x 4.0 | 3 | 1 | 8 | 75 | 7.41 | 27 |
1 x 6.0 | 3 | 1 | 9 | 90 | 4.61 | 35 |
1 x 10.0 | 7 | 1 | 10 | 105 | 3.08 | 47 |
1 x 16.0 | 7 | 1 | 11 | 140 | 1.91 | 65 |
1 x 25.0 | 7 | 1.2 | 12.5 | 195 | 1.2 | 84 |
1 x 35.0 | 7 | 1.2 | 13.5 | 235 | 0.868 | 105 |
1 x 50.0 | 19 | 1.4 | 15 | 305 | 0.641 | 130 |
1 x 70.0 | 19 | 1.4 | 17 | 385 | 0.443 | 155 |
1 x 95.0 | 19 | 1.6 | 19 | 515 | 0.32 | 190 |
1 x 120.0 | 37 | 1.6 | 21 | 610 | 0.253 | 220 |
1 x 150.0 | 37 | 1.8 | 22.5 | 735 | 0.206 | 250 |
1 x 185.0 | 37 | 2 | 25 | 885 | 0.164 | 290 |
1 x 240.0 | 61 | 2.2 | 28 | 1100 | 0.125 | 335 |
1 x 300.0 | 61 | 2.4 | 30 | 1335 | 0.1 | 380 |
1 x 400.0 | 61 | 2.6 | 34 | 1665 | 0.0778 | 435 |
1 x 500.0 | 61 | 3 | 38 | 2130 | 0.0605 | 480 |
1 x 630.0 | 91 | 3.4 | 43 | 2685 | 0.0469 | 550 |
1 x 800.0 | 91 | 3.4 | 48.6 | 3207 | 0.0367 | 640 |
1 x 1000.0 | 91 | 3.4 | 53.8 | 3913 | 0.0291 | 720 |
Cable Structure
Core Size | Stranding(Minimum No. of Strands) | Nominal Thickness of Insulation(mm) | Nominal Overall Diameter(mm) | Approx. Weight (Kg/Km) | Max DC Resistance at 20 Degree C | Current Rating(amp) |
SQ.MM | ||||||
1 x 95.0 | 19 | 1.9 | 21 | 1200 | 0.193 | 245 |
1 x 120.0 | 37 | 1.9 | 22 | 1460 | 0.153 | 280 |
1 x 150.0 | 37 | 2.1 | 24 | 1770 | 0.124 | 320 |
1 x 185.0 | 37 | 2.3 | 26 | 2170 | 0.0991 | 370 |
1 x 240.0 | 61 | 2.5 | 29 | 2740 | 0.0754 | 425 |
1 x 300.0 | 61 | 2.7 | 32 | 3360 | 0.0601 | 475 |
1 x 400.0 | 61 | 3 | 36 | 4400 | 0.047 | 550 |
1 x 500.0 | 61 | 3.4 | 40 | 5450 | 0.0366 | 590 |
1 x 630.0 | 91 | 3.9 | 44 | 6820 | 0.0283 | 660 |
1 x 800.0 | 91 | 3.9 | 52.8 | 4974 | 0.0367 | 640 |
1 x 1000.0 | 91 | 3.9 | 57.9 | 5851 | 0.0291 | 720 |
Cable Structure
Class 5 ABC
EPR Insulation
Cores Twisted
NBR Outer Sheathed, black
Cable Structure
Class 5 ABC
PVC Insulation
Cores Twisted
Almylar and ATC drain wire shielded
PVC Outer Sheathed