  • Model Name/Number Economy MHIL 504
  • Brand Wilo
  • Maximum inlet pressure 6 Bar
  • Maximum operating pressure 10 Bar
  • Min. fluid temperature -15 DegreeC
  • Max. fluid temperature 90 DegreeC
  • Mains connection 230 V, 50 Hz
  • Voltage tolerance +/-10 %
  • Rated power 0.75 kW
  • Rated current 5.10 A
  • Rated speed 2900 1/min
  • Power factor 0.98
View Complete Details

Water Pump

  • Presure booster pump domestic monoblock

We bring forth an extensive range of Water Pumps. Highly appreciated for its excellent performance and optimum functionality, our range finds application in commercial and industrial sectors to cater various water solution applications of the clients. Furthermore, these products can be availed in customized form to suit the variegated requirements of our clients.

Additional Information:

Payment Terms :

Packaging Details : cartoon box and wooden box

Delivery Time : as per customer requirement and job work

View Complete Details

Glandless Circulator Water Pump (Wilo-Yonos MAXO)

We are reckoned as one of the prime Suppliers of Glandless Circulator Water Pump (Wilo-Yonos MAXO) in India. Our Glandless Circulator Water Pump (Wilo-Yonos MAXO) is a glandless circulation pump with threaded connection or flange connection and EC motor with automatic power adjustment. Avail Glandless Circulator Water Pump (Wilo-Yonos MAXO) from us, which is used in hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits and industrial circulation systems. Our Glandless Circulator Water Pump (Wilo-Yonos MAXO) has a LED display for showing delivery head setting. The pump housing of our Glandless Circulator Water Pump (Wilo-Yonos MAXO) is done with cataphoretic coating for preventing corrosion due to condensation formation.

Design : Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment.

Application : Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.


Type key :
Example : Wilo-Yonos MAXO 300.5-12

  • Yonos MAXO : High-efficiency pump (screw-end or flange-end pump), electronically controlled
  • 30 : Nominal connection diameter
  • 0.5-12 : Nominal delivery head range [m]

    • Special featuresproduct advantages :

      • Maximum efficiency thanks to ECM technology
      • LED display for showing delivery head setting
      • Quick and convenient electrical connection with Wilo-Plug
      • Collective fault signal on all types for assuring system availability
      • Simple installation due to PN 6PN 10 combination flanges (with DN 40 to DN 65)
      • Can be used in coolingair-conditioning systems without ambient temperature limits
      • Pump housing with cataphoretic coating for preventing corrosion due to condensation formation
        • Equipmentfunction :Operating modes

          • p-c for constant differential pressure
          • p-v for variable differential pressure

            • Manual functions :

              • Operating mode setting
              • Setting of pump output (delivery head)

                • Automatic functions :

                  • Variable power adjustment depending on the operating mode
                  • Deblocking function
                  • Soft start
                  • Integrated full motor protection

                    • Signal and display functions :

                      • Collective fault signal (potential-free NC contact)
                      • Fault signal light
                      • LED segment display for displaying the delivery head and fault codes

                        • Equipment :

                          • Wrench attachment point on pump body (for threaded pipe union pumps)
                          • Quick electrical connection with Wilo-Plug. For the connection of the mains and SSM lines, with integrated strain relief
                              • For flange-end pumps: Flange versions
                                • Standard version for DN 40 to DN 65 pumps: PN 610 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges

                                    • Scope of delivery :

                                      • Pump
                                      • Including gaskets for threaded connection
                                      • Incl. washers for flange screws (for nominal connection diameters DN 40 - DN 65)
                                      • Including installation and operating instructions

                                        • Accessories :

                                          • Screwed connections for threaded connection
                                          • Adapter fittings
                                          • Thermal insulation
View Complete Details

Inline Water Pump

The company holds expertise in supplying excellent quality Inline Water Pump. With assured trouble free performance and durability, our Inline Water Pump is highly efficient with EC motor and electronic duty adaptation in glanded construction. The control range of our Inline Water Pump is up to three times as high as for conventional electronically controlled pumps. We are offering Inline Water Pump that is manufactured in extremely compact and space saving design. In addition to this, our Inline Water Pump comes with integrated electronic control and integrated dual pump management.

Design : High-efficiency inline pump with EC motor and electronic duty adaptation in glanded construction. Version as single-stage low-pressure centrifugal pump with flange connection and mechanical shaft seal.

Application : Pumping of heating water (acc. to VDI 2035), cold water and waterglycol mixtures without abrasive substances in heating, cold water and cooling systems.

Type key :
Example : Wilo-Stratos GIGA 401-514.5

  • Stratos : High-efficiency pump
  • GIGA : Inline single pump
  • 40 : Nominal flange diameter DN
  • 1-51 : Nominal delivery head range in [m]
  • 4.5 : Rated motor power P2 in kW
  • -R1 : Version without differential pressure sensor

    • Special featuresproduct advantages :

      • Innovative high-efficiency pump for maximum overall efficiency based on a new Wilo glanded design
      • High-efficiency EC motor (efficiency above IE4 limit values acc. to IEC TS 60034-31 Ed.1)
      • Highly efficient hydraulics, optimally adapted to the EC motor technology, with optimised efficiency, minimum efficiency index (MEI) 0.7 according to ErP Directive 2009125EC [Commission Regulation (EU) 5472012].
      • Integrated electronic control
      • Control range is up to three times as high as for conventional electronically controlled pumps
      • Extremely compact and space-saving design
      • Simple operation thanks to tried-and-tested red-button technology and display
      • Optional interfaces for bus communication using plug-in IF-Modules
      • Integrated dual pump management
      • Fault management tailored to HVAC applications
      • Access disable on the pump
      • High standard of corrosion protection thanks to cataphoretic coating
      • Condensate drainage as standard
      • Pump bases with threaded hole for installation in the foundation

        • Technical data :

          • Permitted temperature range of the fluid -20oC to +140oC
          • Mains connection
          • 3380 V - 3480 V (10 %), 50 Hz60 Hz
          • Protection class IP 55
          • Max. operating pressure 16 bar up to +120oC, 13 bar up to +140oC

            • Equipmentfunction : Operating modes

              • p-c for constant differential pressure
              • p-v for variable differential pressure
              • PID control
              • Manual control mode (n=constant)

                • Manual operation level : Red button and display

                  Manual functions :

                  • Differential pressure setpoint setting
                  • Speed setting (manual control mode)
                  • Operating mode setting
                  • Pump ONOFF setting
                  • Configuration of all operating parameters
                  • Error acknowledgement

                    • External control functions :

                      • "Overriding Off" control input
                      • "External pump cycling" control input (effective only in double pump operation mode)
                      • Analogue input 010 V, 020 mA for manual control mode (DDC) and remote setpoint adjustment
                      • Analogue input 210 V, 420 mA for manual control mode (DDC) and remote setpoint adjustment
                      • Analogue input 010 V for actual value signal from pressure sensor
                      • Analogue input 210 V, 0-20 mA, 420 mA for actual value signal from pressure sensor

                        • Signal and display functions :

                          • Collective fault signal SSM
                          • Collective run signal SBM

                            • Data exchange : Infrared interface for wireless data exchange with IR-ModuleIR-StickPlug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation

                              Safety functions :

                              • Full motor protection with integrated trip electronics
                              • Access disable
                              • Dual pump management (double pump or 2 x single pump)
                              • Mainstandby operation (automatic fault-actuated switchover)
                              • Pump cycling mainstandby operation after 24 hours
                              • Parallel operation
                              • Parallel operation (efficiency-optimised peak-load activation and deactivation)

                                • Scope of delivery :

                                  • Pump
                                  • Installation and operating instructions

                                    • Options : Version -R1 without differential pressure sensor

                                      Accessories :

                                      • 3 Mounting brackets with fixation material for installation on a base
                                      • Installation aid for mechanical seal
                                      • IR-Monitor
                                      • IR-Stick
                                      • IF-Module PLR for connecting to PLRinterface converter
                                      • IF-Module LON for connection to the LONWORKS network
                                      • IF-Module BACnet
                                      • IF-Module Modbus
                                      • CAN IF-Module
                                      • VR-HVAC control system
                                      • Control system CCe-HVAC
                                      • Control system SCe-HVAC
                                      • Differential pressure sensor (DDG)

                                        • General notes - ErP (ecological design-) directive :

                                          • The benchmark for most efficient water pumps is MEI 0.70
                                          • The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.
                                          • The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system.
                                          • Information on benchmark efficiency is available at