Post Buy Requirement
NB
Delhi, India
Add Review

Our Products #3207024

Alarm Control Panels

UL Listed, Maximum 4 Signal Line Curcuits (loops), Maximum 127 addressable device any combination of detector or module.
View Complete Details

Fire Extinguishing Systems

100% nitorgen (N2) gas as extinguishing agent, 30MPa storage pressure to minimize cylinder requirment, Pressure regulating type N2 storage cylinder valve, Extinguishing by reducing O2 concentration below 15%, N2 not toxic gas, No toxic byproduct in extinguishing, Design concentration 33.6% for NFPA Class A fire, Centralized cylinder bank for multiple zone protection.
View Complete Details

Spray Suppression System

Patented EXXFIRE Cool Gas Generator is technology derived from rocket technology. The non pressurized, solid propellant is stored as a chemical block inside integrated engineered housing. An initiator starts the decomposition of the propellant releasing N2 gas at ambient temperature into protection area, Integrated system with early smoke detection and suppression. Less consequential damage compare to Nheat detection, Easy to install, Built-in Battery, Low maintenance, Self Msystem check.
View Complete Details

Fire Fighting Sprinklers

UL Listed, 100% nitorgen (N2) gas as extinguishing agent, 30MPa storage pressure to minimize cylinder requirment, Pressure regulating type N2 storage cylinder valve, Extinguishing by reducing O2 concentration below 15%, Zero ODP, Zero GWP, N2 not toxic gas, No toxic byproduct in extinguishing, Clear view during after N2 discharge, Centralized cylinder bank for multiple zone protection.
View Complete Details

Fire Detectors

The Photoelectric Smoke Detector (FDKU012-PSA) is an AnalogAddressable smoke detector compatible with any fire alarm control panel ofInteglex Multicrest series. The FDKU012-PSA is a low profile smoke detector with a wide sensitivity range. The detector and base (not included) are made of a durable plastic in an eggshell white (off white) to blend in with the ceiling.The FDKU012-PSA has a sensitivity range of 3.4 to 12.0 %m 1.05 to 3.82% per foot and is UL and cUL listed. The FDKU012-PSA can be configured for drift compensation and has built in dirty detector warning as well as. The FDKU012-PSA and the control panel communicate over a proven and robust digital communication path and the system analyzes the level of alarm at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements.
View Complete Details

Water Detection System

Stand alone type with 24 VDC powe supply, Total scattered light detection method, Powerful large flow rate aspiration fan (- 350Pa), Maximum coverage 2400 sqm (UL) and 2000 sqm (FM, Bar graph indicators, Storage warehouse, Semiconductor manufacturing equipments.
View Complete Details

Inert Gas Generator

Cool Gas Generator is technology derived from rocket technology. The non pressurized, solid propellant is stored as a chemical block inside integrated engineered housing. An initiator starts the decomposition of the propellant releasing N2 gas at ambient temperature into protection area.
View Complete Details

Addressable Monitor Module

Maximum 255 addressable device (any combination of Ndetector or module), Network expansdable upto 64 nodes, Comprehensive information display on LCD, Address Map display on LCD, Trend graph display of detector sensor level on LCD, Action guidance message on LCD, Machine time display (component runnint time).
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Ankit Srivastava (Nohmi Bosai India Pvt Ltd.)
  • , Delhi, India
  • Share us via