Post Buy Requirement
PA
Mumbai, Maharashtra, India
Add Review

Other Products / Services #5791223

Gas Purification

  • Pressure Regulators Maximum inlet pressure 10 kg / cm²
  • Size of Pannel 420W x 600H x 87D in mm (Model GPP-01)
  • Net weight 14 kg. (Model GPP-01)
  • Toggle valve On / off type
  • Pressure Guages 0 - 10 kg / cm² Pannel mounting
  • Pannel Body Powder coated wall mounted design with optional safety frame & fully S.S. body
  • Tubings S.S. / Copper / Nylon with colour coaded sleeves

Salient Features & Benefits:

Deliver Ultra High Pure (UHP) Grade GasesCompact Design, Wall Mounted, Powder CoatedFilters are easily detachableSuitable for 10kg/cm inlet pressure & 7 kg/cm outlet pressurePanel for LC-MS-MS & other applications are also availableReduce baseline noise, drift problems, etc.Increase column life, GC detectors & reduces flame problemsImprove reproducibilitySave costly gases through toggle valves & gas distribution panel.

APPLICATION FILTER TYPE MAX. INLET
IMPURITY LEVEL
MAX. OUTLET
IMPURITY LEVEL
LENGTH
End to End
CAPACITY
Moisture Removal Silicagel / Molecular Sieve 20 ppm < 3 ppm 10" 210 CC
Hydro Carbon
Removal
Activated
Charcoal / Carbon
10 ppm < 2 ppm 10" 210 CC
Oxygen Removal De-Oxo
Chemical catalyst
10 ppm < 2 ppm 8" 125 CC
Particle Removal Micron Filter 25 μ < 0.5 μ 2"






View Complete Details

Inline Micron Filters

Inline Micron Filters are used to remove dust particles from respective gases. Micron filter (SSbody) consist of SS disc (Mesh) of 5 - 10.
Gas purification panel removes impurities which are in vapours (gases) form. Cylinders being M.S.body has the tendency to illute dust particles, these particles may come in the line and may go togas chromatograph. To avoid this particles micron filters are very essential.

View Complete Details

Casing Capping

Tubing are available in different sizes like 1/2", 1/4", 1/8", 1/16"
Tubing available in different MOC like copper, S.S., teflon, nylon.
Casing capping are used to cover the above tubing & to maintain theesthetic look.
Three types casing capping available, M.S. powder coated, alluminiumpowder coated & PVC casing capping.

View Complete Details

Cylinder Trolley And Cylinder Mounting Bracket

Cylinder trolley in MS powder coated 4 wheel for smooth & safe operation.
Cylinder trolley available for single & two cylinder.
Cylinder mounting brackets are used to mount the cylinder on wall to avoid down fall of cylinder.
Mounting bracket available with wall and floor mounting.
Gas sampling bottle is used for storing / transporting gas sample at high & low pressure. Available in250ml, 500ml, 1000ml & above
Air header is used for the distribution of compress air or any gas with one inlet various outlet withneedle / ball valve.

View Complete Details

Gas Cylinder Regulators

  • Type Single-stage / Double-stage
  • Material of construction SS 316 / Brass Chromplated
  • Diaphagram SS 316 with Teflon Seat
  • Pressure Gauges SS 316 / Brass
  • Inlet Pressure 0-210 kg/cm², 0-280 kg/cm²
  • Outlet Pressure 0-14 kg/cm², 0-16 kg/cm²/ as per requirement
  • Flow (LPH) 300 (max)
  • Outlet Connection 1/4, 1/8 Swage lock / Hose

PCI Manufacturers Various kinds of Regulators. PCI Regulators have been designedto meet the demand of High Purity Corrosion Resistance ProductSpecially Suitedfor low level PPM Moisture

Two types of Cylinder Regulators available Brass Chrome Plated body with SSdiaphragm and SS body with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge showsthe total pressure of cylinder and outlet pressure gauge shows regulated pressure.High pressure piston type Regulator & Regulators for corrosive gases likeAmmonia, Clorine, etc. are also available.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm in diaphragm typeOutlet pressure range: 0 - 40, 0 - 70, 0 - 100 kg/cm in piston type

Double Stage Cylinder Regulator specifications :Two types of Cylinder Regulators available Brass Chrome Plated body with SS diaphragm and SSbody with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge shows the totalpressure of cylinder and outlet pressure gauge shows regulated pressure.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm diaphragm type

Cylinder Regulator- Acetylene/N2O/Argon Specifications :Cylinder Regulator for the controlling of outlet pressure of cylinder for Acetylene & Nitrous oxide &Argon gasM. O. C. : Brass Chromplated Body or SS Body with SS DiaphragmPre heater for Nitrous oxide gas

View Complete Details

Gas Detection System

Features:Dual display of gas concentration & set point/ unit of the gasPlug in smart field proven sensorProgrammable linear 4-20mA/ 20-4mA O/P with respect to gasconcentrationEasy one man calibration at siteOptional RS-485 with modbus RTU protocolSuitable in hazardous area ATEX, CCOE, CMRI & IP-65 approved.

Applications:Gas cylinder bankGas pipeline projectChemical processing plantRefineriesChemical & petrochemical plantsOil & gas industriesFertilizers plantsGas metering stationChemical storage area

View Complete Details

Oxygen Analyser

Oxygen Analyser is used to detect the Oxygen level in any given gas, Oxygen Analyser available in PPM and Percentage type. Oxygen Analyser are of different ranges 0-30%, 0-100% & 0-5000 PPM, Oxygen Analyser has electrochemical type sensor. Oxygen Analyser has Digital display with 2 PPM or 0.01% resolution. Maximum operating pressure and temperature is 0.5bar and Ambient plus or minus 10 degree Celsius.

View Complete Details

Air Compressors

Air Compressors is used for Analytical instruments like AAs, NMR, TOC etc. Air Compressors are oil free, oil based. Air Compressors are reciprocating, screw & Scroll type. Air Compressors for AAs is used to produce flame by reacting with Acetylene.

CPM / CPA Features:

Electric screw compressors
Starting from 5.5kw/7.5hp to15kw/20hp
FAD 22 cfm to 71 cfm
Available in three pressure variant 7, 10 & 13 bar (g)
Also available with inverter drive (IVR)

Model Motor Rating
HP
Piston Displacement Operating
Pressure
Tank
Capacity
LPM CFM    
Anest Iwata
TFS 10B-9 1 151 5.34 125 8.5 40
TFS 20B-9 2 267 9.44 125 8.5 80
TFS 30B-9 3 408 14.41 125 8.5 80
TFS 50B-9 5 649 22.93 125 8.5 160
TFS 75B-9 7.5 692 24.43 125 8.5 250
TFS 100B-9 10 1038 36.66 125 8.5 250
Indian
HS-WP-1T 0.75 60 2 100 7 20
HS-WP-2T 1 100 3.5 100 7 20
PCI-KI-20T(Imp) 0.75 60 2 100 7 20
Chicago Pneumatic
CPM 5 5 460 16.6 62 10 200
CPM 7 7.5 590 21.2 65 10 200
CPA 10/7 10 1170 42 68 7 500
CPA 10/10 10 980 35 68 10 500
CPA 15/7 15 1625 58 68 7 500
CPA 15/10 15 1400 50 68 10 500
CPA 20/7 20 1980 71 68 7 500
CPA 20/10 20 1765 63 68 10 500



View Complete Details

Air Dryer

PSA/Desicant Air Dryer:Standard compressed air enters to PSA unit where all the impurities like: moisture, CO, CO2 etc areremoved to produced clean dry air upto -60 dew point.

Refrigerated Air Dryer:Standard compressed air enters to the Air to Air heat exchange, where it is pre cooled by out going cold dryair. Highly effective pre cooler reduces the temperature considerably, and enable to use smaller &economical refrigeration system. Then the pre cooled, relatively low temperature compressed air enters toAir to Refrigerant heat exchanger, where it is cooled down to +3C (Pressure Dew Point). At thistemperature, moisture in vapour form condensed to liquid form, and separated from the compressed air bymoisture separator and discharged to drain port through automatic drain valve. Thecold dry compressesair passes back to Air to Air Heat Exchanger, and gain temperature by exchanging heat with incoming warmair. The dry air coming out from the dryer is ready to use for instrumentation and process air applications.

Model Capacity
CFM
Working Pressure
kg/cm²
Connections
BSP
Refrigerant Power supply
v/ph
Condensor type Nominal power Consumption
kw
Overall Dimensions in mm Approx Weight (kgs.)
L B H
PPS-15 15 16 1/2" R134a 220/1 Air 0.19 350 350 550 25
PPS-24 24 16 1/2" R134a 220/1 Air 0.19 400 500 550 32
PPS-45 45 16 1/2" R134a 220/1 Air 0.37 400 500 550 35
PPS-60 60 16 3/4" R134a 220/1 Air 0.37 550 550 730 60
PPS-80 80 16 3/4" R134a 220/1 Air 0.60 550 550 730 65
PPS-100 100 16 1 1/2" R134a 220/1 Air 0.60 550 750 900 78
PPS-150 150 16 1 1/2" R134a 220/1 Air 1.11 700 750 900 90
PPS-200 200 16 1 1/2" R134a 220/1 Air 1.11 700 750 900 92





View Complete Details

Gas Detector

1) GAS TRANSMITTER ( PCI-GT-1000 FLP)3" wire gas transmitter with LED display, 4-20mA output in Flameproof Enclosure with Catalyst Sensor for Combustible gas.

  1. Gas to be detected : Hydrogen OR Methane OR Acetylene OR Hydrocarbon OR LPG
  2. Range : 0 to 100% LEL
  3. Output: 4 to 20 mA
  4. Supply Voltage: 24V DC
  5. Detection Principal: Catalytic Pellistor
  6. Sensor life: 5 years
  7. Sensor Body: SS316
  8. Enclosure: IIC enclosure
  9. Mounting: Wall Mounting OR Stand Mounting

2) MULTICHANNEL GAS MONITOR UNIT 1 44, 000.00 EACH Model: (PCI -TC 100 WP) mounted in Main compartment of Mild Steel Powder Coated Paint Finish Body.Micro-controller based Scanner type monitor. Digital Display for easy to read Gas Concentration online on monitor with two window display for Channel assessment and actual value of gas analyses per channel. Acknowledge function with user friendly operation & programmable by easy soft Key

  • Output: Two High and Low common relay for alarm
  • Input supply: 230 VAC FOR Single ChannelORFor 4 ChannelORFOR 08 ChannelORFOR 16 Channel


3) HOOTER CUM FLASHER Standard Hooter 1 6, 000.00 EACH for Safe Area.

  • Input Supply : 24 V DC / 230 V AC
  • Output : 100 dB
  • Enclosure :Weatherproof
  • Dimension : 96 X 96 mm e) Mounting : Wall Mounting


4) CABLE (3 core X 1.5 mm2) Armored Shielded Cable 1 190.00 METER for Gas Transmitter to Monitor (Quantity on Actually Running Meter)7/0.3mm (0.5sq mm) in continuous contact with Aluminum side of the tape, PVC inner sheathed of types STI as per IS 5831/84 with 0.5 mm thickness in Black color, galvanized steel wire armored as per IS 583/84 in Black color suitable for 1100 V." (Qty. on actual running meter basis).

View Complete Details

Ultrasonic Bath

High frequency electrical energy is converted into ultrasound waves by means of ultrasonic Tranducers, which are bonded on the base of S. S. Water Tank. These high frequency sound waves create in the liquid countless, Microscopic Vacuum Bubbles, which repidly expand and collapse. This phenomenon is CAVITAION. These bubbles act like miniature high speed brushes, driving the liquid in to all openings and minutes recesses of the Object immersed in the liquid. Intense scrubbing of Cavitation cleans away all the dirt and soil from the object immersed and the object is perfectly cleaned. Intricate objects can be cleaned with either complete or little Dismantling.

  • Higher capacity other than menstioned are also available as per customer requirements.
  • Different shapes basket available
  • Weight Rings of differences sizes available for different measuring cylinders (2cm or 3cm)

Capacity Tank Size
(LxBxH) mm
Overall Dimension
(LxBxH) mm
Wattage
1.5 Lit 240x135x65 265x160x180 60W
3.5 Lit. 300x150x100 330x175x250 120W
6.5 Lit. 300x150x150 450x200x350 200W
9 Lit. 300x200x150 450x300x375 250W

 



View Complete Details

Hplc Column Oven

  • Applicable input PT-100, 2- Wire
  • Accuracy ± 0.1
  • Resolution 0.1 ºC
  • Stability 0.1 ºC
  • Stabilisation Time 15 min

Salient Features :Precise Temperature ControlDigital display of set & actual temp.Insures Reproducible AnalysisAccepts Varieties of Column SizesAssures Safe, Accurate Control action

Model Selection :HCO-01 : Separate Oven & Temp. ControllerHCO-02 : Inbuilt temperature controller & ovenHCO-03 : Inbuilt heating of Rheodyne InjectorHCO-04 : Force air circulation heating type oven

Consist of :
Micro Controller based / PID Temperature ControllerOven Module

View Complete Details

Sterility Test Unit

Sterility Test Unit47mm Stainless Steel (3 Branch Sterility)

Sterility Test Unit47mm Stainless Steel (6 Branch Sterility

Oil Free Vacuum Pump suitable for above Sterility
Model - PCI-75-S
Max. Flow - 45 LPM, Vacuum - 27" Hg (680 mm)
Max. Pressure - 55 PSig, 1/4 HP

View Complete Details

NUCLEOSIL HPLC COLUMN

MACHEREY-NAGEL, the manufacturer of NUCLEOSIL HPLC phases and one of the leading companies forchromatography products, presents its Reversed Phase Application Guide.
The 160-page publication includes an introduction to the theoretical aspects of HPLC, a lot of information about
modern stationary phases, retention, selectivity and mobile phases.
Aside 150 up-to-date and relevant applications the special chapters Dos and Donts and trouble-shooting provide a lotof helpful hints and tips for a successful chromatography. A special sectionexplains basic aspects and demands of preparative HPLC.
The applications are divided in the fields of:
Drugs
Biological and natural compounds
Food analysis
Environmental analysis
Organic compounds

View Complete Details

Polystyrene Film

Polystyrene Calibration FilmsRadially Symmetric Polystyrene Calibration Films & Calibration Films Cast On KBr Windows( U.S. Patent No. 6, 254, 931-- Other Patents Pending)
Boron Doped KBr Calibration Windows(U.S. Patent No. 6, 594, 008)
PhEur 2.2.24 Calibration Standards

In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations. This makes the films consistent from film to film. Sold in pairs of two (2) different film thickness, the differential between the absorbance intensities created by the two (2) film thickness becomes the baseline, thereby making the pair of films suitable both as an ordinate calibration standard useful for detection of degradation in instrument performance and for calibrating the abscissa scale in accordance with NIST Standard 1921. Films are available in free standing pairs mounted on 2 x 4 cards that fit in the standard universal slide mount in all spectrophotometers or the films can be cast on KBrwindows. Films cast on KBr windows will not exhibit any interference fringes. KBrwindows with films are sold with a mount with a 2 x 3 back plate that fits the standard universal slide mount in all spectrophotometers.The polystyrene coating prevents degradation of the KBrwindow from moisture effects. Boron doped crystal windows are also available as calibration standards. These windows can be matched in pairs with comparable absorbances.

Part No.
Description

0009-2500Polystyrene Test Film - 38 microns thick

0009-8181Polystyrene Test Film - 76 microns thick

0009-8182Pair of polystyrene calibration films of different thickness. One film is 38 microns and is provided with certification of traceability to five (5) NIST 1921b frequencies. The second film is 76 microns and is provided without certification. Both films are mounted on 2" x 3" cardstock holder with a 19mm aperture for mounting in the universal slide holder in all instruments. Includes instructions for two (2) film ordinate calibration and storage case. Also available with PhEur 2.2.24 certified polystyrene calibration film (inquire for quote).

0009-8487Same as 0009-8182, but with PhEur 2.2.24 certified films.

0009-7676NIST traceable Polystyrene Test film, certificate of traceability to five (5) NIST 1921b frequencies, set of 2 films each mounted to 2 x 4 cardstock holder

0009-7393Pair of polystyrene films of different thickness, both with NIST traceability certification. Kit also includes a pair of standard polystyrene films, but without NIST traceability certification. One NIST traceable film is mounted on 2" x 4" cardstock, which enables mounting in the standard universal slide mount found in all spectrophotometers, and is the same thickness as an NIST 1921 standard film (38 microns). The second thinner NIST traceable film is cast on KBr and includes holder and mounting device. Kit includes certification of traceability to five (5) NIST 1921b frequencies, radial symmetry certification for film cast on KBr and storage cases for all films.

0009-7394Pair of polystyrene calibration films of different thickness cast on KBr, radial symmetry certification, summary of NIST standard 1921 with frequency locations, certification of traceability to five (5) NIST 1921b frequencies, instructions for two (2) film ordinate calibration, slide mount holder. Kit also includes a pair of standard polystyrene films, without NIST traceability certification, mounted on 2" x 4" cardstock which enables mounting in the standard universal slide mount found in all spectrophotometers. Storage case provided.

0009-9247Pair of 13mm x 2mm KBr windows intended to fit FTIR microscope stage, coated with polystyrene and certified to five (5) NIST 1921b frequencies

0009-7395Single Boron doped KBr Crystal calibration standard with slide mount holder and storage case. (U.S. Patent No. 6, 594, 008)

0009-7396Pair of matched Boron doped KBr windows.(U.S. Patent No. 6, 594, 008)

0009-8157Polystyrene calibration film for PhEur 2.2.24 calibration of IR and FTIR instruments, certified to 7 wave-numbers and certified as to absorption minima and maxima differentials at 2870 cm-1and 2849.5cm-1and at 1589 cm-1and 1583 cm-1.

0009-8158Pair of PhEur 2.2.24 certified polystyrene calibration films, same as 0009-8157 but with 2 certified films.

0009-8559Polystyrene Calibration film for PhJap 2.25 calibration of IR and FTIR instruments, certified to 7 wave numbers, mounted on 2" x 4" card stock.

0009-8558Pair of PhJap 2.25 certified polystyrene calibration films, same as 0009-8559 but with 2 certified Films.

0009-8560Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24.

0009-8448Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24 and also certified to PhJap 2.25.

0009-8437Pair of films same as 0009-8448

0009-9248Custom Cut Polystyrene film cut to the size of any Horizontal ATR accessory (please specify, up to 4" square), certified to five (5) NIST 1921b frequencies

View Complete Details

Recirculating Water Chillers

  • Inner Chamber SS Duly Polished
  • Outer Chamber M.S. Powder Coated / SS
  • Insulation Duly insulate by P.U.F.
  • Flow capacity 20 ltrs. / min at height of 1 meter
  • Outlet connection 3/8” OD

The recirculating chillers are designed to handle high coolingcapacities. These chillers operate in the temperature range from+5C to atmosphere and have built in high pressure pump. Thesechillers are useful to cool other instruments which generate heat.Viz. Lasers, Furnaces, XRD, etc., Graphite Furnace, Fermenters, Thermal Instruments, Rotary Evaporator.

Water Chiller Unit:It consists of chilled water storage tank of about8-15 liters capacity along with Compressor, Condensing Coils, Cooling Fan, Temperature Controller Programable type, Water Inlet& Outlet connection and chilled water circulation pump to circulatechilled water through S.S. cooling coils and bring back to chiller tank.Control Panel consists of temperature & ready status of ChillerON/OFF Switch, with Red Coloured Indicator Green colouredindicator which indicates Initial Power ONThis has an Inbuilt delay of about 1-2 minutes for the Compressorto be ON.Switch for Chilled Water circulation pump. This has no time delay.This is fitted in a Floor Mounting type with Castor Wheels(optional).

View Complete Details

Gas Distribution Panel

Gas Distribution PanelGas distribution panel is used when there is more than one Gas Chromatograph.It helps to controlled the flow & pressure of different gases for different GC's.Available in three different types. One is with pressure gauge, pressure regulator, ON/OFF valve. Second with pressure gauge and ON/OFFvalve.Third is with onlyON/OFF valve.

Gas Selector BoxUsed for the selection between two gases of different types.Available in two different types one with selector valve, pressure gauge & togglevalve, another with only two toggle valve.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • PCI Analytics Pvt. Ltd (PCI Analytics Pvt. Ltd)
  • No. 3/14-15, Bhandup Industrial Estate, Pannalal Compound, L.B.S. Marg, Bhandup(W), - 400 078, Bhandup West, Mumbai, Maharashtra
  • Share us via
List of Other Products by PCI Analytics Pvt. Ltd from Mumbai, Maharashtra.
Post Buy Requirement
PA
Mumbai, Maharashtra, India
Add Review

Other Products / Services #5791223

Gas Purification

  • Pressure Regulators Maximum inlet pressure 10 kg / cm²
  • Size of Pannel 420W x 600H x 87D in mm (Model GPP-01)
  • Net weight 14 kg. (Model GPP-01)
  • Toggle valve On / off type
  • Pressure Guages 0 - 10 kg / cm² Pannel mounting
  • Pannel Body Powder coated wall mounted design with optional safety frame & fully S.S. body
  • Tubings S.S. / Copper / Nylon with colour coaded sleeves

Salient Features & Benefits:

Deliver Ultra High Pure (UHP) Grade GasesCompact Design, Wall Mounted, Powder CoatedFilters are easily detachableSuitable for 10kg/cm inlet pressure & 7 kg/cm outlet pressurePanel for LC-MS-MS & other applications are also availableReduce baseline noise, drift problems, etc.Increase column life, GC detectors & reduces flame problemsImprove reproducibilitySave costly gases through toggle valves & gas distribution panel.

APPLICATION FILTER TYPE MAX. INLET
IMPURITY LEVEL
MAX. OUTLET
IMPURITY LEVEL
LENGTH
End to End
CAPACITY
Moisture Removal Silicagel / Molecular Sieve 20 ppm < 3 ppm 10" 210 CC
Hydro Carbon
Removal
Activated
Charcoal / Carbon
10 ppm < 2 ppm 10" 210 CC
Oxygen Removal De-Oxo
Chemical catalyst
10 ppm < 2 ppm 8" 125 CC
Particle Removal Micron Filter 25 μ < 0.5 μ 2"






View Complete Details

Inline Micron Filters

Inline Micron Filters are used to remove dust particles from respective gases. Micron filter (SSbody) consist of SS disc (Mesh) of 5 - 10.
Gas purification panel removes impurities which are in vapours (gases) form. Cylinders being M.S.body has the tendency to illute dust particles, these particles may come in the line and may go togas chromatograph. To avoid this particles micron filters are very essential.

View Complete Details

Casing Capping

Tubing are available in different sizes like 1/2", 1/4", 1/8", 1/16"
Tubing available in different MOC like copper, S.S., teflon, nylon.
Casing capping are used to cover the above tubing & to maintain theesthetic look.
Three types casing capping available, M.S. powder coated, alluminiumpowder coated & PVC casing capping.

View Complete Details

Cylinder Trolley And Cylinder Mounting Bracket

Cylinder trolley in MS powder coated 4 wheel for smooth & safe operation.
Cylinder trolley available for single & two cylinder.
Cylinder mounting brackets are used to mount the cylinder on wall to avoid down fall of cylinder.
Mounting bracket available with wall and floor mounting.
Gas sampling bottle is used for storing / transporting gas sample at high & low pressure. Available in250ml, 500ml, 1000ml & above
Air header is used for the distribution of compress air or any gas with one inlet various outlet withneedle / ball valve.

View Complete Details

Gas Cylinder Regulators

  • Type Single-stage / Double-stage
  • Material of construction SS 316 / Brass Chromplated
  • Diaphagram SS 316 with Teflon Seat
  • Pressure Gauges SS 316 / Brass
  • Inlet Pressure 0-210 kg/cm², 0-280 kg/cm²
  • Outlet Pressure 0-14 kg/cm², 0-16 kg/cm²/ as per requirement
  • Flow (LPH) 300 (max)
  • Outlet Connection 1/4, 1/8 Swage lock / Hose

PCI Manufacturers Various kinds of Regulators. PCI Regulators have been designedto meet the demand of High Purity Corrosion Resistance ProductSpecially Suitedfor low level PPM Moisture

Two types of Cylinder Regulators available Brass Chrome Plated body with SSdiaphragm and SS body with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge showsthe total pressure of cylinder and outlet pressure gauge shows regulated pressure.High pressure piston type Regulator & Regulators for corrosive gases likeAmmonia, Clorine, etc. are also available.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm in diaphragm typeOutlet pressure range: 0 - 40, 0 - 70, 0 - 100 kg/cm in piston type

Double Stage Cylinder Regulator specifications :Two types of Cylinder Regulators available Brass Chrome Plated body with SS diaphragm and SSbody with SS diaphragm.Regulator consist of inlet & outlet pressure gauges. Inlet pressure gauge shows the totalpressure of cylinder and outlet pressure gauge shows regulated pressure.Inlet pressure range: 0 - 240 kg/cmOutlet pressure range: 0 - 14 kg/cm diaphragm type

Cylinder Regulator- Acetylene/N2O/Argon Specifications :Cylinder Regulator for the controlling of outlet pressure of cylinder for Acetylene & Nitrous oxide &Argon gasM. O. C. : Brass Chromplated Body or SS Body with SS DiaphragmPre heater for Nitrous oxide gas

View Complete Details

Gas Detection System

Features:Dual display of gas concentration & set point/ unit of the gasPlug in smart field proven sensorProgrammable linear 4-20mA/ 20-4mA O/P with respect to gasconcentrationEasy one man calibration at siteOptional RS-485 with modbus RTU protocolSuitable in hazardous area ATEX, CCOE, CMRI & IP-65 approved.

Applications:Gas cylinder bankGas pipeline projectChemical processing plantRefineriesChemical & petrochemical plantsOil & gas industriesFertilizers plantsGas metering stationChemical storage area

View Complete Details

Oxygen Analyser

Oxygen Analyser is used to detect the Oxygen level in any given gas, Oxygen Analyser available in PPM and Percentage type. Oxygen Analyser are of different ranges 0-30%, 0-100% & 0-5000 PPM, Oxygen Analyser has electrochemical type sensor. Oxygen Analyser has Digital display with 2 PPM or 0.01% resolution. Maximum operating pressure and temperature is 0.5bar and Ambient plus or minus 10 degree Celsius.

View Complete Details

Air Compressors

Air Compressors is used for Analytical instruments like AAs, NMR, TOC etc. Air Compressors are oil free, oil based. Air Compressors are reciprocating, screw & Scroll type. Air Compressors for AAs is used to produce flame by reacting with Acetylene.

CPM / CPA Features:

Electric screw compressors
Starting from 5.5kw/7.5hp to15kw/20hp
FAD 22 cfm to 71 cfm
Available in three pressure variant 7, 10 & 13 bar (g)
Also available with inverter drive (IVR)

Model Motor Rating
HP
Piston Displacement Operating
Pressure
Tank
Capacity
LPM CFM    
Anest Iwata
TFS 10B-9 1 151 5.34 125 8.5 40
TFS 20B-9 2 267 9.44 125 8.5 80
TFS 30B-9 3 408 14.41 125 8.5 80
TFS 50B-9 5 649 22.93 125 8.5 160
TFS 75B-9 7.5 692 24.43 125 8.5 250
TFS 100B-9 10 1038 36.66 125 8.5 250
Indian
HS-WP-1T 0.75 60 2 100 7 20
HS-WP-2T 1 100 3.5 100 7 20
PCI-KI-20T(Imp) 0.75 60 2 100 7 20
Chicago Pneumatic
CPM 5 5 460 16.6 62 10 200
CPM 7 7.5 590 21.2 65 10 200
CPA 10/7 10 1170 42 68 7 500
CPA 10/10 10 980 35 68 10 500
CPA 15/7 15 1625 58 68 7 500
CPA 15/10 15 1400 50 68 10 500
CPA 20/7 20 1980 71 68 7 500
CPA 20/10 20 1765 63 68 10 500



View Complete Details

Air Dryer

PSA/Desicant Air Dryer:Standard compressed air enters to PSA unit where all the impurities like: moisture, CO, CO2 etc areremoved to produced clean dry air upto -60 dew point.

Refrigerated Air Dryer:Standard compressed air enters to the Air to Air heat exchange, where it is pre cooled by out going cold dryair. Highly effective pre cooler reduces the temperature considerably, and enable to use smaller &economical refrigeration system. Then the pre cooled, relatively low temperature compressed air enters toAir to Refrigerant heat exchanger, where it is cooled down to +3C (Pressure Dew Point). At thistemperature, moisture in vapour form condensed to liquid form, and separated from the compressed air bymoisture separator and discharged to drain port through automatic drain valve. Thecold dry compressesair passes back to Air to Air Heat Exchanger, and gain temperature by exchanging heat with incoming warmair. The dry air coming out from the dryer is ready to use for instrumentation and process air applications.

Model Capacity
CFM
Working Pressure
kg/cm²
Connections
BSP
Refrigerant Power supply
v/ph
Condensor type Nominal power Consumption
kw
Overall Dimensions in mm Approx Weight (kgs.)
L B H
PPS-15 15 16 1/2" R134a 220/1 Air 0.19 350 350 550 25
PPS-24 24 16 1/2" R134a 220/1 Air 0.19 400 500 550 32
PPS-45 45 16 1/2" R134a 220/1 Air 0.37 400 500 550 35
PPS-60 60 16 3/4" R134a 220/1 Air 0.37 550 550 730 60
PPS-80 80 16 3/4" R134a 220/1 Air 0.60 550 550 730 65
PPS-100 100 16 1 1/2" R134a 220/1 Air 0.60 550 750 900 78
PPS-150 150 16 1 1/2" R134a 220/1 Air 1.11 700 750 900 90
PPS-200 200 16 1 1/2" R134a 220/1 Air 1.11 700 750 900 92





View Complete Details

Gas Detector

1) GAS TRANSMITTER ( PCI-GT-1000 FLP)3" wire gas transmitter with LED display, 4-20mA output in Flameproof Enclosure with Catalyst Sensor for Combustible gas.

  1. Gas to be detected : Hydrogen OR Methane OR Acetylene OR Hydrocarbon OR LPG
  2. Range : 0 to 100% LEL
  3. Output: 4 to 20 mA
  4. Supply Voltage: 24V DC
  5. Detection Principal: Catalytic Pellistor
  6. Sensor life: 5 years
  7. Sensor Body: SS316
  8. Enclosure: IIC enclosure
  9. Mounting: Wall Mounting OR Stand Mounting

2) MULTICHANNEL GAS MONITOR UNIT 1 44, 000.00 EACH Model: (PCI -TC 100 WP) mounted in Main compartment of Mild Steel Powder Coated Paint Finish Body.Micro-controller based Scanner type monitor. Digital Display for easy to read Gas Concentration online on monitor with two window display for Channel assessment and actual value of gas analyses per channel. Acknowledge function with user friendly operation & programmable by easy soft Key

  • Output: Two High and Low common relay for alarm
  • Input supply: 230 VAC FOR Single ChannelORFor 4 ChannelORFOR 08 ChannelORFOR 16 Channel


3) HOOTER CUM FLASHER Standard Hooter 1 6, 000.00 EACH for Safe Area.

  • Input Supply : 24 V DC / 230 V AC
  • Output : 100 dB
  • Enclosure :Weatherproof
  • Dimension : 96 X 96 mm e) Mounting : Wall Mounting


4) CABLE (3 core X 1.5 mm2) Armored Shielded Cable 1 190.00 METER for Gas Transmitter to Monitor (Quantity on Actually Running Meter)7/0.3mm (0.5sq mm) in continuous contact with Aluminum side of the tape, PVC inner sheathed of types STI as per IS 5831/84 with 0.5 mm thickness in Black color, galvanized steel wire armored as per IS 583/84 in Black color suitable for 1100 V." (Qty. on actual running meter basis).

View Complete Details

Ultrasonic Bath

High frequency electrical energy is converted into ultrasound waves by means of ultrasonic Tranducers, which are bonded on the base of S. S. Water Tank. These high frequency sound waves create in the liquid countless, Microscopic Vacuum Bubbles, which repidly expand and collapse. This phenomenon is CAVITAION. These bubbles act like miniature high speed brushes, driving the liquid in to all openings and minutes recesses of the Object immersed in the liquid. Intense scrubbing of Cavitation cleans away all the dirt and soil from the object immersed and the object is perfectly cleaned. Intricate objects can be cleaned with either complete or little Dismantling.

  • Higher capacity other than menstioned are also available as per customer requirements.
  • Different shapes basket available
  • Weight Rings of differences sizes available for different measuring cylinders (2cm or 3cm)

Capacity Tank Size
(LxBxH) mm
Overall Dimension
(LxBxH) mm
Wattage
1.5 Lit 240x135x65 265x160x180 60W
3.5 Lit. 300x150x100 330x175x250 120W
6.5 Lit. 300x150x150 450x200x350 200W
9 Lit. 300x200x150 450x300x375 250W

 



View Complete Details

Hplc Column Oven

  • Applicable input PT-100, 2- Wire
  • Accuracy ± 0.1
  • Resolution 0.1 ºC
  • Stability 0.1 ºC
  • Stabilisation Time 15 min

Salient Features :Precise Temperature ControlDigital display of set & actual temp.Insures Reproducible AnalysisAccepts Varieties of Column SizesAssures Safe, Accurate Control action

Model Selection :HCO-01 : Separate Oven & Temp. ControllerHCO-02 : Inbuilt temperature controller & ovenHCO-03 : Inbuilt heating of Rheodyne InjectorHCO-04 : Force air circulation heating type oven

Consist of :
Micro Controller based / PID Temperature ControllerOven Module

View Complete Details

Sterility Test Unit

Sterility Test Unit47mm Stainless Steel (3 Branch Sterility)

Sterility Test Unit47mm Stainless Steel (6 Branch Sterility

Oil Free Vacuum Pump suitable for above Sterility
Model - PCI-75-S
Max. Flow - 45 LPM, Vacuum - 27" Hg (680 mm)
Max. Pressure - 55 PSig, 1/4 HP

View Complete Details

NUCLEOSIL HPLC COLUMN

MACHEREY-NAGEL, the manufacturer of NUCLEOSIL HPLC phases and one of the leading companies forchromatography products, presents its Reversed Phase Application Guide.
The 160-page publication includes an introduction to the theoretical aspects of HPLC, a lot of information about
modern stationary phases, retention, selectivity and mobile phases.
Aside 150 up-to-date and relevant applications the special chapters Dos and Donts and trouble-shooting provide a lotof helpful hints and tips for a successful chromatography. A special sectionexplains basic aspects and demands of preparative HPLC.
The applications are divided in the fields of:
Drugs
Biological and natural compounds
Food analysis
Environmental analysis
Organic compounds

View Complete Details

Polystyrene Film

Polystyrene Calibration FilmsRadially Symmetric Polystyrene Calibration Films & Calibration Films Cast On KBr Windows( U.S. Patent No. 6, 254, 931-- Other Patents Pending)
Boron Doped KBr Calibration Windows(U.S. Patent No. 6, 594, 008)
PhEur 2.2.24 Calibration Standards

In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations. This makes the films consistent from film to film. Sold in pairs of two (2) different film thickness, the differential between the absorbance intensities created by the two (2) film thickness becomes the baseline, thereby making the pair of films suitable both as an ordinate calibration standard useful for detection of degradation in instrument performance and for calibrating the abscissa scale in accordance with NIST Standard 1921. Films are available in free standing pairs mounted on 2 x 4 cards that fit in the standard universal slide mount in all spectrophotometers or the films can be cast on KBrwindows. Films cast on KBr windows will not exhibit any interference fringes. KBrwindows with films are sold with a mount with a 2 x 3 back plate that fits the standard universal slide mount in all spectrophotometers.The polystyrene coating prevents degradation of the KBrwindow from moisture effects. Boron doped crystal windows are also available as calibration standards. These windows can be matched in pairs with comparable absorbances.

Part No.
Description

0009-2500Polystyrene Test Film - 38 microns thick

0009-8181Polystyrene Test Film - 76 microns thick

0009-8182Pair of polystyrene calibration films of different thickness. One film is 38 microns and is provided with certification of traceability to five (5) NIST 1921b frequencies. The second film is 76 microns and is provided without certification. Both films are mounted on 2" x 3" cardstock holder with a 19mm aperture for mounting in the universal slide holder in all instruments. Includes instructions for two (2) film ordinate calibration and storage case. Also available with PhEur 2.2.24 certified polystyrene calibration film (inquire for quote).

0009-8487Same as 0009-8182, but with PhEur 2.2.24 certified films.

0009-7676NIST traceable Polystyrene Test film, certificate of traceability to five (5) NIST 1921b frequencies, set of 2 films each mounted to 2 x 4 cardstock holder

0009-7393Pair of polystyrene films of different thickness, both with NIST traceability certification. Kit also includes a pair of standard polystyrene films, but without NIST traceability certification. One NIST traceable film is mounted on 2" x 4" cardstock, which enables mounting in the standard universal slide mount found in all spectrophotometers, and is the same thickness as an NIST 1921 standard film (38 microns). The second thinner NIST traceable film is cast on KBr and includes holder and mounting device. Kit includes certification of traceability to five (5) NIST 1921b frequencies, radial symmetry certification for film cast on KBr and storage cases for all films.

0009-7394Pair of polystyrene calibration films of different thickness cast on KBr, radial symmetry certification, summary of NIST standard 1921 with frequency locations, certification of traceability to five (5) NIST 1921b frequencies, instructions for two (2) film ordinate calibration, slide mount holder. Kit also includes a pair of standard polystyrene films, without NIST traceability certification, mounted on 2" x 4" cardstock which enables mounting in the standard universal slide mount found in all spectrophotometers. Storage case provided.

0009-9247Pair of 13mm x 2mm KBr windows intended to fit FTIR microscope stage, coated with polystyrene and certified to five (5) NIST 1921b frequencies

0009-7395Single Boron doped KBr Crystal calibration standard with slide mount holder and storage case. (U.S. Patent No. 6, 594, 008)

0009-7396Pair of matched Boron doped KBr windows.(U.S. Patent No. 6, 594, 008)

0009-8157Polystyrene calibration film for PhEur 2.2.24 calibration of IR and FTIR instruments, certified to 7 wave-numbers and certified as to absorption minima and maxima differentials at 2870 cm-1and 2849.5cm-1and at 1589 cm-1and 1583 cm-1.

0009-8158Pair of PhEur 2.2.24 certified polystyrene calibration films, same as 0009-8157 but with 2 certified films.

0009-8559Polystyrene Calibration film for PhJap 2.25 calibration of IR and FTIR instruments, certified to 7 wave numbers, mounted on 2" x 4" card stock.

0009-8558Pair of PhJap 2.25 certified polystyrene calibration films, same as 0009-8559 but with 2 certified Films.

0009-8560Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24.

0009-8448Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24 and also certified to PhJap 2.25.

0009-8437Pair of films same as 0009-8448

0009-9248Custom Cut Polystyrene film cut to the size of any Horizontal ATR accessory (please specify, up to 4" square), certified to five (5) NIST 1921b frequencies

View Complete Details

Recirculating Water Chillers

  • Inner Chamber SS Duly Polished
  • Outer Chamber M.S. Powder Coated / SS
  • Insulation Duly insulate by P.U.F.
  • Flow capacity 20 ltrs. / min at height of 1 meter
  • Outlet connection 3/8” OD

The recirculating chillers are designed to handle high coolingcapacities. These chillers operate in the temperature range from+5C to atmosphere and have built in high pressure pump. Thesechillers are useful to cool other instruments which generate heat.Viz. Lasers, Furnaces, XRD, etc., Graphite Furnace, Fermenters, Thermal Instruments, Rotary Evaporator.

Water Chiller Unit:It consists of chilled water storage tank of about8-15 liters capacity along with Compressor, Condensing Coils, Cooling Fan, Temperature Controller Programable type, Water Inlet& Outlet connection and chilled water circulation pump to circulatechilled water through S.S. cooling coils and bring back to chiller tank.Control Panel consists of temperature & ready status of ChillerON/OFF Switch, with Red Coloured Indicator Green colouredindicator which indicates Initial Power ONThis has an Inbuilt delay of about 1-2 minutes for the Compressorto be ON.Switch for Chilled Water circulation pump. This has no time delay.This is fitted in a Floor Mounting type with Castor Wheels(optional).

View Complete Details

Gas Distribution Panel

Gas Distribution PanelGas distribution panel is used when there is more than one Gas Chromatograph.It helps to controlled the flow & pressure of different gases for different GC's.Available in three different types. One is with pressure gauge, pressure regulator, ON/OFF valve. Second with pressure gauge and ON/OFFvalve.Third is with onlyON/OFF valve.

Gas Selector BoxUsed for the selection between two gases of different types.Available in two different types one with selector valve, pressure gauge & togglevalve, another with only two toggle valve.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • PCI Analytics Pvt. Ltd (PCI Analytics Pvt. Ltd)
  • No. 3/14-15, Bhandup Industrial Estate, Pannalal Compound, L.B.S. Marg, Bhandup(W), - 400 078, Bhandup West, Mumbai, Maharashtra
  • Share us via