Our Product / Services
Our Complete range of products are RESQ GT 33 Online UPS System, RESQ 1-10 KVA Online UPS System, RESQ 3/1- 10-30 KVA Online UPS System and RESQ-3/3 Online UPS System.
Features
Specifications
| Model | RESQ30GT33 | RESQ40GT33 | RESQ60GT33 | RESQ80GT33 | RESQ100GT33 | RESQ120GT33 | RESQ160GT33 | RESQ200GT33 |
|---|---|---|---|---|---|---|---|---|
| Capacity | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | 100KVA/80KW | 120KVA/96KW | 160KVA/128KW | 200KVA1160KW |
| Output | ||||||||
| Nominal Voltage | 3 x 380VAC/400VAC (3Ph N) | |||||||
| Acceptable Voltage Range | 285VAC - 475VAC | |||||||
| Frequency | 50/60 Hz ± 10 % | |||||||
| Inverter | ||||||||
| Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||
| Precision | Stationary ± 1% Transitory: t5% (load variations 100% - 0% - 100%) | |||||||
| Frequency | 50/60 He synchronised ±1 %With mains absent ±0.1 Hz | |||||||
| Max. Synchronisation Speed | ±1 Hz/s | |||||||
| Waveform | Pure Sinewave | |||||||
| Total Harmonic Distortion (THDv) | <2% (Linear Load) <5% (Non-linear Load) | |||||||
| Phase Displacement | 120° ± 1% (balanced load) 120°± 2% (imbalances upto 50% of the load) | |||||||
| Dynamic Recovery Time | 3 cycles at 90 % of the static value | |||||||
| Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||||
| Admissible Crest Factor | 3:1 | |||||||
| Admissible Power Factor | 0.6-1 (inductive or capacitive) | |||||||
| Imbalance Output Voltage @ 100% Unbalanced Load Current Limit | <1% | |||||||
| Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | |||||||
| Static Bypass | ||||||||
| Type | Solid state | |||||||
| Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||
| Frequency | 50/60 Hz | |||||||
| Activation Criterion | Microprocessor control | |||||||
| Transfer Time | Zero | |||||||
| Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||||
| Transfer to Bypass | Immediate, for overloads above 160% | |||||||
| Retransfer | Automatic after alarm clear | |||||||
| Maintenance Bypass | ||||||||
| Type | Without interruption | |||||||
| Voltage | 3 x 400V (3Ph + N) | |||||||
| Frequency | 50/60 Hz | |||||||
| Overall Efficiency | ||||||||
| Line Mode | 90.00% | 91.00% | 92.00% | |||||
| Battery Mode | 91.00% | 92.00% | 93.00% | |||||
| Battery & Charger | ||||||||
| Battery Type and Numbers | 12VDC x 32 pcs (29-32 p. adjustable) | |||||||
| Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | |||||||
| Charging Method | CC/CV | |||||||
| Precision | ±1% | |||||||
| Charging Current | *Default 10A; Maximum 40A; 5A@ full load | |||||||
| Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||||
| Physical | ||||||||
| Dimensions, D X W H(mm) | 656x405x941 | 821x432x1159 | 975x554x1286 | 975x554x1326 | 1051x705x1646 | |||
| Net weights (kgs) | 193 | 278 | 365 | 471 | 573 | 650 | 760 | 840 |
Applications :
Specifications
| Model | RES16KLB | RESQ2KLB | RESQ3KLB | RESQ6KLB | RESQ1OKLB | |
|---|---|---|---|---|---|---|
| Phase | Single phase with ground | |||||
| Capacity | 1000 VA/800 W | 2000 VA/1600 W | 3000 VA/2400 W | 6000 VA/4800 W | 10000 VA/8000 W | |
| Input | ||||||
| Nominal Voltage | 200/208/220/230/240VAC | 208/220/230/24UVAC | ||||
| Input Voltage Range | 110-300 VAC (Based on load at 50%) 160-280VAC (Based on load at 100%) | 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) | ||||
| Frequency Range | 40Hz - 70 Hz | 46-54 Hz or 56-64 Hz | ||||
| Power Factor | ≥0.99 @ Nominal Voltage (100% load) | |||||
| Output | ||||||
| Output Voltage | 200/208/220/230/240 VAC | 208/220/230/240 VAC | ||||
| AC Voltage Regulation (Batt. Mode) | ±1% | |||||
| Frequency Range (Synchronized Range) | 47~53Hz or 57-63Hz | 46~54Hz or 56-64Hz | ||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz | 50 Hz or 60 Hz ± 0.1 Hz | ||||
| Crest Factor | 3:1 | |||||
| Harmonic Distortion | ≤3 % THD (linear Load) , ≤6 % THD (Non-linear Load) | ≤3 % THD (linear Load) , ≤5 % THD (Non-linear Load) | ||||
| Transfer Time | ||||||
| AC Mode to Battery Mode | Zero | |||||
| Inverter to Bypass | 4 ms (typical) | Zero | ||||
| Waveform (Batt. Mode) | Pure Sinewave | |||||
| Efficiency | ||||||
| Overall Efficiency | > 90% | |||||
| Battery | ||||||
| Number of batteries | 3 | 6/8 | 16/20 | |||
| Charging Current (max.) | 1A/2A/4A/6A (Adjustable) | 1A/2A/4A/6A (Adjustable), 6A is only available for 16 pcs. Batteries) | ||||
| INDICATORS | ||||||
| LCD Panel | Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||||
| Alarm | ||||||
| Battery Mode | Sounding every 4 seconds | |||||
| Low Battery | Sounding every second | |||||
| overload | Sounding twice every second | |||||
| Fault | Continuously sounding | |||||
| Physical | ||||||
| Dimension, DXWXH (mm) | 282x145x220 | 397x145x220 | 369x190x318 | 442x190x318 | ||
| Net Weight (kgs) | 4.1 | 6.8 | 7.4 | 12 | 16 | |
| Environment | ||||||
| Operation Humidity | 20-90 % RH 0- 40°C (non-condensing) | 0-95 % RH 0- 50°C (non-condensing) | 0-95 % RH 0- 40°C (non-condensing) | |||
| Noise Level | Less than 58dBA @ 1 Meter | Less than55dBA @ 1 Meter | Less than 58dBA @ 1 Meter | |||
| Management | ||||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC | |||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||
| Standards | IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS | |||||
Specifications
| Model | RESQ10KLB31 | RESQ10KL31 | RESQ15KL31 | RESQ20KL31 | RESQ30KL31 | |
|---|---|---|---|---|---|---|
| Phase | 3 Phase in/ 3 phase Out | |||||
| Capacity | 10000 VA/8000 W | 10000 VA/9000 W | 15000 VA/13500 W | 20000 VA/18000 W | 30000 VA/27000 W | |
| Input | ||||||
| Nominal Voltage | 3 x 400 VAC (3Ph-N) | |||||
| Voltage Range | 190-520 VAC (3-phase) @ 50% load | |||||
| Frequency Range | 305-478 VAC (3-phase) @ 100% load | |||||
| Power Factor | ≥ 0.99 @100%load | |||||
| ThDi | < 6% @ 100% load | |||||
| Output | ||||||
| Output Voltage | 0.99 @ 100% load | |||||
| AC Voltage Regulation (Batt. Mode) | ±1% | |||||
| Frequency Range (Synchronized Range) | 46-54Hz or 56-64Hz | |||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||||
| Crest Factor | 3:1 | |||||
| Harmonic Distortion | ≤2 % THD (linear Load) , ≤5 % THD (Non-linear Load) | |||||
| Transfer Time | ||||||
| AC Mode to Battery Mode | Zero | |||||
| Inverter to Bypass | Zero | |||||
| Waveform (Batt. Mode) | Pure Sinewave | |||||
| Efficiency | ||||||
| Overall Efficiency | > 92% | |||||
| Battery | ||||||
| Number of batteries | 18 - 20 Adjustable | |||||
| Charging Current (max.) | 4A | 4A | 8A | 8A | 12A | |
| Charging Voltage | 273 VDC t 1% (Based on 20pcs batteries) | |||||
| INDICATORS | ||||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||||
| Alarm | ||||||
| Battery Mode | Sounding every 4 seconds | |||||
| Low Battery | Sounding every second | |||||
| overload | Sounding twice every second | |||||
| Fault | Continuously sounding | |||||
| Physical | ||||||
| Dimension, DXWXH (mm) | 442x190x318 | 592 x 250 x 826 | 592 x 250 x 576 | 592 x 250 x576 | 815 x 250 x 826 | |
| Net Weight (kgs) | 16 | 28 | 40 | 40 | 64 | |
| Environment | ||||||
| Operation Humidity | 0-95 % RH 0- 40°C (non-condensing) | |||||
| Noise Level | Less than 58dBA @ 1 Meter | Less than 60dBA @ 1 Meter | Less than 65dBA @ 1 Meter | |||
| Management | ||||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC | |||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||
| Standards | IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS | |||||
The information contained in this publication is subject to change without prior notice.
Application :
Specifications
| Model | RESQ10KL33 | RESQ15KL33 | RESQ20KL33 | RESQ30KL33 |
|---|---|---|---|---|
| Phase | 3 Phase in/ 3 phase Out | |||
| Capacity | 10000 VA/9000 W | 15000 VA/13500 W | 20000 VA/18000 W | 30000 VA/27000 W |
| Input | ||||
| Nominal Voltage | 3 x 400 VAC (3Phi-N) | |||
| Voltage Range | 190-520 VAC (3-phase) @ 50% load | |||
| Frequency Range | 305-478 VAC (3-phase) @ 100% load | |||
| Power Factor | 46-54 Hz or 56-64Hz | |||
| Output | ||||
| Output Voltage | 0.99 @ 100% load | |||
| AC Voltage Regulation (Batt. Mode) | 3 x 400 VAC (3Ph+N) ± 1% | |||
| Frequency Range (Synchronized Range) | 46-54Hz or 56-64Hz | |||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||
| Crest Factor | 3:1 | |||
| Harmonic Distortion | 5 2 % THD (Linear Load) 5 5 % THD (Non-linear Load) | |||
| Transfer Time | ||||
| AC Mode to Battery Mode | Zero | |||
| Inverter to Bypass | Zero | |||
| Waveform (Batt. Mode) | Pure Sinewave | |||
| Efficiency | ||||
| Overall Efficiency | > 92% | |||
| Battery | ||||
| Number of batteries | 18 - 20 Adjustable | |||
| Charging Current (max.) | 4A | 4A | 4A | 12A |
| Charging Voltage | 273 VDC t 1% (Based on 20pcs batteries) | |||
| INDICATORS | ||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||
| Alarm | ||||
| Battery Mode | Sounding every 4 seconds | |||
| Low Battery | Sounding every second | |||
| overload | Sounding twice every second | |||
| Fault | Continuously sounding | |||
| Physical | ||||
| Dimension, DXWXH (mm) | 592 x 250 x 826 | 592 x 250 x 826 | 592 x 250 x 826 | 815 x 250 x 826 |
| Net Weight (kgs) | 38 | 40 | 40 | 64 |
| Environment | ||||
| Operation Humidity | 0-95 % RH 0- 40°C (non-condensing) | |||
| Noise Level | Less than 60dBA 0 1 Meter | Less than 65dBA 0 1 Meter | ||
| Management | ||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC | |||
| Optional SNMP | Power management from SNMP manager and web browser | |||
| Standards | IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS | |||
The information contained in this publication is subject to change without prior notice.