My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Battery Chargers 5 Products available
  2. Relays 5 Products available
  3. Measuring Instruments & Equipment 5 Products available
  4. Voltage Stabilizer 4 Products available
  5. Sensors 3 Products available
  6. Mosquito And Insect Repellent 2 Products available
  7. Level Transmitters 2 Products available
  8. Level Controllers 1 Products available
  9. Emergency Lights 1 Products available
  10. UPS 1 Products available
  11. Inverters, UPS & Converters 1 Products available
  12. Transformers 1 Products available
  13. Welding Machine Parts 1 Products available
  14. Others Products 11 Products available

Level Transmitters

Our offered Product range includes Nurse Call Monitoring System and Micro Controller Based Nurse Call Monitoring System.

Nurse Call Monitoring System

We are offering nurse call monitoring system. Bps offers digital call indicator and monitoring systems for hospitals and nursing homes. The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience. These are installed in many leading hospitals for years and are working with full satisfaction of each hospital. Very simple to install and maintain. system over view:each bed is provided with call station board consisting of bed pushconfirmation light and re-set push. The patient can make call formthe push switch. On receipt of call at the digital display board, confirmation light on the call station will be on. This ensures thatthere is no problem in wiring. The call received at display board canonly be re-set by the attending nurse from the re-set push providedat the bed side of patient (call station board). On attending the call, the confirmation light and the bed number at the monitor will beswitched off. If any call remains pending over a set period the particular number will be hi-lighted by flushing the digit & buzzer installed at the floor in-chargematron will be activated.this will help in avoiding any negligence in services. the system will comprise ofa) call station board, b) door indicator, c) digital display board, d) data logger carde) ups system call station boardis consisting of bed push confirmation light and re-set push. It is designed for standard modular box. door indicator:is consisting of cluster of leds mounted in specially designed cabinet. It has tangle round red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the nurses moving by to attend immediately even before going to the nurses station. digital display board:the digital display board is call monitor console which is installed at the nurse center. All call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one nurse station. It has soft buzzer which alerts the attendment on receipt of any new calls. call station boardis consisting of bed push confirmationlight and re-set push. It is designedfor standard modular box. data logger card:this is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thusgenerated helps the hospital management in taking appropriate decisions. The card is supported with specially developed softwar which is installed in the computer. ups system. The system has its own specially designed ups. It is consisting of a smf type 12 v 7 ah battery, automatic battery charger and allied accessories. unique advantages are: low voltage operation:the incoming mains is converted to 12 v.d.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. digital display of bed nos:with 2-3 digit bright led displays, bed number can be easily noticed from a distance. non attendance timer:each call received activates a built in timer and after a specified time, it activates a buzzer. battery backup:to facilitate making call even during power cut, the system is provided with a battery backup. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. cost effective solution:this system is very cost effective for installation and maintenance computer connectivity :with add-on card, the system can record each event and helps management in taking appropriate and logical decision. ordering information bps d20 d30 digital nurses call monitoring system. item description model no. quatity requried call station boardwith 3 " x 3" ms box, acralic cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb1 each bed = 1 setwith 3 " x 3" ms box, modular cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb2 (pb1 or pb2) door indicatorwith 8 nos red leds, red acrylic coversuitable for connecting up to 8 bedsin one room bncm-du-1 optional for each roomwith 3 colour leds, flash study offfunctions, acknowledge push, acraliccover suitable for connecting up to 4beds in one room bncm-du-2 digital display board with 2digit displaywith one no 2 digit display card, acralic cover, in ms box of 275 x 125 x 50 mm bncm-d2ca up to 6 bedswith two no. 2 digit display card, acralic cover, in ms box of 275 x 225 x 50 mm bncm-d2cb up to 12 bedswith three no.2 digit display card, acralic cover, in ms box of 300 x 325 x 50 mm bncm-d2cc up to 18 bedswith four no. 2 digit display card, acralic cover, in ms box of 300 x 460 x 50 mm bncm-d2cd up to 24 bedswith five no.2 digit display card, acralic cover, in ms box of 350 x 550 x 50 mm bncm-d2ce up to 30 bedswith six no.2 digit display card, acralic cover, in ms box of 350 x 6000 x 50 mm bncm-d2cf up to 36 bedsdigital display board with 3digitdisplay with oneno. 3 digit display card, acralic cover, in ms box of 300 x 125 x 50 mm bncm-d3ca up to 5 bedswith two no.3 digit display card, acralic cover, in ms box of 300 x 225 x 50 mm bncm-d3cb up to10 bedswith three no.3 digit display card, acralic cover, in ms box of 300 x 350 x 50 mm bncm-d3cc up to 15 bedswith four no.3 digit display card, acralic cover, in ms box of 300 x 450 x 50 mm bncm-d3cd up to 20 bedswith fiveno.3 digit display card, acralic cover, in ms box of 300 x 550 x 50 mm bncm-d3ce up to 25 bedswith six no. 3 digit display card, acralic cover, in ms box of 600 x 475 x 50 mm bncm-d3cf up to 30 bedsdata logger card computer interferance card with softwar fitted in enclosure bncm-dlc -1 up to 36 beds.ups sytem power supply with automatic battery charger, smf 12 v. 7 ah battery bncmups1 up to 36 beds=1 setwires frombed tocallstation 2 pair telephone wire as per distance from bedsto call station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Micro Controller Based Nurse Call Monitoring System

We are offering micro controller based nurse call monitoring system. How to monitor and fix-up responsibility. to ensure the practice is followed, the system must be reliable and must have built in mechanism to point out delay in action. nurses call monitoring system series 640 informs the nursing staff the sequence of call received thus minimizing any over due call. The call register maintains sequence in which call from different bed are received. the first call pending is displayed with big 2 7 segment display. 4 other calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. if any call is pending beyond set time, the number starts blinking. It also activates a buzzer to draw attention of the nursing staff. If call remains pending even beyond 2nd limit, rate of blinking is intensified to bring notice of problem. micro-controller based systemserial display of calls received-1st call displayed with 2" height leddisplay, next 4 calls in sequence on sidecolumn, further pending calls- onscrolling 3 digit 7 segment displays. soft tone buzzer- alerts receipt of new call elegant look compact and flexible- table- wall mountable. built in non attendance timer- pending calls flash- long pending calls flash at higher rates modular bed side console- easy installation in std. Modular cabinet status indicators and buttons- ready, call & wait led indicationon board, with call & reset switch elegant patient remote low voltage operation- the system works on 12 v. D.c hence patient is not put to danger even due toaccidental snatching of wires. reset at patient bed- re-set button installed near the patient. compact and flexible- the system requires very low space andis flexible to accommodates up to 64 beds. next generation system fromindustry leader leaders in nurses call monitoring system in india bps team is presenting the latest technical innovation in the line. The system is designed by our in house team to suit indian conditions. system over view series 640 consists of mainly the following sub-systems: a) call station boardb) patient remote hand setc) door indicatord) toilet pull corde) master controller hubf) nurses monitor console call station board each bed is provided with call station board. This is housed in standard console. It has push switches to call and re-set the call. led indications for ready(green), call(red), and wait(yellow) are provided. Ready led indicates that the system is ok and call can be made. If there is any problem with wiring, it will not glow. This is built in system to give instant check of any system or wiring fault. led marked call lights up when the call is made. Once the call is made and it is registered with the controller hub, led marked wait glows indicating call has reached nurse station. patient remote hand setfrom call station, remote patient hand set is provided so that the patient can make call form his bed. Remote hand set has push to make call. Led indication for ready, call and wait are provided. door indicatordoor indicator is installed out side the room to indicate call pending in the room. This facilitates nursing staff to attend on way to nurse station. One door indicator can announce pending call forup to 8 beds in the same room. Door indicators are available with many features like color leds, hold switch etc. toilet pull cord:toilet pull cord with indicator & rope. Standard length of rope is 1.5m. This pull cord is installed in side the toilet. Patient can use the pull cord in toilet. master controller hub:controller hub is central unit installed near nurse monitor console. It is consisting of one micro-processor central controller card, one connector card for up to 16 beds smps. Wires from all beds are terminated on connector pcb. It receives information fromeach bed and signals the console to display the information. nurses monitor consolethe call monitor console will be installed at the nurse center. Call received from any bed will be displayed by the respective bed number by 3 digit 7 segment led display. It can be mounted on wall or table stand. The first call pending is displayed with big 2 7 segment display. Other 4 calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. connections:two pair telephone cable will be required to connect each bed to display board. Telephone type socket is punched to wires from each bed. Mains supply of 230 v ac is required at controller hub. low voltage operation:the incoming mains is converted to 12 v. D.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. compact and flexible:the system requires very low space and is flexible to add on as the number of beds increases. Marking on he indication board can be custom designed for easy location and is editable. our expertisenurses call monitoring systems and queue management systems by team bps is installed in all the leading hospitals in eastern india. With over 15 years of feed back from actual working condition in hospitals, continuous improvement in design, innovation of technology we are presenting series 640-the most advanced nurses call monitoring system. The system is designed with utmost reliability, dependability, safety, and flexibility in mind. ordering informationitem description model no. quantity reburiedcall station board with membrane push switches for call and re-set buttons& leds for ready, call and wait, connector for console connectionand connector for patient remote hand set bncm-pb640a each bed = 1 setpatientremote handset with flexible wire of 2 meters, telephone type jack connector, switch for call and indication for ready, call & wait bncm-pb640r each bed = 1 setdoor indicator with 8 nos red leds, red acrylic cover for connecting up to 8 bedsin one room bncm-du-1 optionalwith 3 colour leds, flash study off functions, acknowledge push, acrylic cover suitable for connecting up to 4 beds in one room bncm-du-2 for each roomtoilet pullcord toilet pull cord with indicatorrope length standard 1.5 m bncm-tpc1 for each toiletmaster controllerhub type-1 with one micro-processor central controller card, one connector cardfor up to 16 beds, power supplies (smps) housed in hinged cabinet bncm-mch640a up to 16 bedsmaster controllerhub type-2 with one micro-processor central controller card, two connector cardfor up to 32 beds power supplies (smps) housed in hinged cabinet bncm-mch640b up to 32 bedsmaster controllerhub type-3 with one micro-processor central controller card, three connector cardfor up to 48 beds power supplies (smps) housed in hinged cabinet bncm-mch640c up to 48 bedsmaster controllerhub type-4 with one micro-processor central controller card, four connector cardfor up to 64 beds power supplies (smps) housed in hinged cabinet bncm-mch640d up to 64 bedsnurse monitorconsole with one 2" height & 4 nos 34" height led displaysuitable for wall mounting and with table stand bncm-nch640a up to 64 bedsdata logger card computer interference card with softwarefitted in enclosure bncm-dlc-2 optionalup to 64 bedswires from bedto call station 2 pair telephone wire as per distance from beds tocall station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us