Post Buy Requirement
PC
Pune, Maharashtra, India
Add Review

Our Products #4645593

Phasing Preventer With Auto Switch

Negative Sequence Voltage Operated Single Phasing Preventor.

Suitable for any H.P. Motor.
Fixed Trip setting at (+ / -) 40 V Unbalance in R.Y.B. Phases.
Auto Switch is provided to start motor automatically when power resumes.
L.E.D. indication is healthy On.
Protection against single phasing, reverse phasing, unbalance voltage.
With flexible wires for connection to starter.

Models Available in Sheet Metal, powder coated boxes.TYPE- PX 501

Models Available in ABS (Plastic) EnclosuresType- PX 501, PX222, S-P-P 1000

View Complete Details

Control Panel

Suitable for Submersible Pump & Open well Pump Protections against Over load & Dry Run with Starting & Running Capacitors.

  • Input Voltage -230 VAC.
  • Current Capacity -25 Amps. Max.
  • Current Setting- 16 Amps. Max.

Available for 0.5 H.P., 0.75 H.P., 1 H.P., 1.5 H.P. and 2 H.P.

Capacitors

H.P. 0.5 H.P. 0.75 H.P. 1 H.P. 1.5 H.P. 2 H.P.
Running Capacitor 25 Mfd 30 Mfd 36 Mfd 36+25 Mfd 36+36 Mfd
Starting Capacitor 100/120 Mfd 100/120 Mfd 100/120 Mfd 120/150 Mfd 150/200 Mfd

SUPPLY/MOTOR TERMINALS

P N R Y B
230VAC. SUPPLY TO MOTOR
View Complete Details

Current Sensing Preventer For Three Phase Pump

Current Sensing Probless Dry Run protection Unit for three phase pumps, protects pumps, from Single Phasing, Reverse Phasing dry run and over load. For higher H.P. kindly contact at the above address.Available for 1 H.P. to 20 H.P. pumps.

View Complete Details

Single Phasing Preventor

Negative Sequence Voltage Operated Single Phasing Preventor.

Suitable for any H.P. Motor.
Fixed Trip setting at (+ / -) 40V. Unbalance in R.Y.B. Phases.
Auto Reset.
Protection against single phasing, reverse phasing, unbalance voltage.
L.E.D. Indication is healthy On.

Models Available in ABS (Plastic) EnclosuresType -1) PX 999 2)PX 503 3) S.P.P.3 4) PX 503

Models Available in Sheet Metal Powder Coated boxesType- POWERTEK SUPER

View Complete Details

Phasing Preventer With Timer

POWERTEK MAKE SINGLE PHASING PREVENTOR WITH AUTO SWITCH WITH TIMER FOR STAR DELTA STARTER

Negative Sequence Voltage Operated Single Phasing Preventor With Auto Switch With Timer On Delay One Minute and change over from Star to Delta in six seconds suitable for S.A.S.D. starter .The same are also available with on delay time of three minutes.

Suitable for any H.P. Motor.
Fixed Trip Setting at (+ / -) 40V Unbalance.
Auto Switch provided to start motor automatically when power resumes after one minute.
Unit Healthy Indication.
For Semi Star Delta Starter changeover from Star to Delta time fixed 6 seconds.

Models available in sheet metal powder coated boxes.TYPE- RX 100, AX 300

View Complete Details

Cyclic Timer

Cylic timer with on time and off time selectable from 5 minutes to 240 Minutes with dry run and overload protection.

View Complete Details

Water Level Guard

POWERTEK MAKE WATER LEVEL GUARD Negative Sequence Voltage Operated Single Phasing Preventer With Water Level Guard With Auto Switch With on delay Timer

Suitable for any H.P. Submersible Pump.
Fixed Trip Setting at (+ / -) 40 V.
Protection against Single Phasing, Reverse Phasing, Unbalance Voltage and dry running with stainless steel sensors.
Auto Switch provided to start motor automatically when power resumes after a delay of one minute.
Test facility on the unit for checking the operation of the preventer.

Models available in sheet metal powder coated boxes TYPE- PX 107

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us