My ExportersIndia

For Buyer

For Seller

For Help

Prima Equipment
gstGST : 24AJKPS9568A1ZV Write a Review

Our Products

Our product range contains a wide range of Handy Air Sampler, Head Space Oxygen Analyzer, Toxic Gas Analyser, FGD-X Fixed Gas Detector and CAAPEMS-91/91O Continous Ambient Air Pollution Monitoring System

Handy Air Sampler

35,000 / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Automation Grade Semi Automatic
  • Application Air Sampling
  • Number Of Flower Air Samplers
  • Total Carbohydrate 1yr
  • Country of Origin India
  • Size 110*70*125 mm
  • Weight 1.4 Kg
  • Power Supply Rechargeable 6V Battery

Introduction:

The personal air sampler model pas25 consists of a mini pump driven by a d.c. motor working on a 6 volt dc rechargeable battery.this work continuously for up to 10 hours between charging. if required, the air sampler can be used, while charging by 220 v ac mains supply.the screw arrangement allows variation of flow rates between 0.5 and 3.0 liters/minute. a flow meter is mounted on the face of the box.pulsation dampers are internally fitted on the inlet and outlet gas circuit to smoothen the air flow. the pump unit is fitted into a m.s. case of compact size.the sampler unit can be kept on a flat surface for stability at the breathing zone level of the worker to take stel (15 mins.)/twa - tl v (8 hour) measurements. the air sampler is supplied with a battery charger in a carrying case.

Applications :

these instrument is applicable for three things, 1) twa-tlv/stel, 2) dusts, fumes, mists and 3) gases, vapours and solvents within factories, plants, government organization, research institutions etc.

1) twa-tlv/stel limits values are statutory requirements. by sampling the breathing air, the short term exposure limit can be determined. otherwise using the sampler for an 8 hour shift the twa - tlv value can be ascertained for the contaminant.

2) dusts, fumes, mists for collection of toxic dusts e.g. arsenic, cadmium, beryllium, carbon black, cobalt, copper, lead, manganese, nickel rhodium, silver or tin, the use of a filter is the simplest. many oxides or metal fumes, produced by casting, welding or burning, may be collected on a filter for analysis.

3) gases, vapours and solvents using the sampler, a convenient collecting method is by adsorption tubes or detector tubes suitable to the gases & vapors to be analyzed or de-adsorbtion for chromatograph analysis of the adsorbent. also, for adsorption into a liquid contained in a bubbler for chemical analysis

Technical Specifications :

Parameter Description

Range 0-2.5l/min with 0.5 lpm graduation

Rating 8 hours after full charge

Flow variation 0.5 to 2.5 lpm

Power rechargeable 6v battery

Recharging on 220 vac mains

Size 110 x 70 x 125 mm

Weight 1.4 kg. approx

Features :

  • Low cost
  • Robust
  • Portable and small
  • 8-hour operation on one charge.
  • Rechargeable battery operated
  • Power on, low battery, charging indicators.

View Complete Details

Head Space Oxygen Analyzer

43,500 - 45,500 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Display Type Digital
  • Usage/Application Industrial Use
  • Brand PRIMA
  • Country of Origin India
  • Size & Weight 195 x 98 x 155 mm depth, 1.5 Kgs approx.

The PRIMA Head Space Oxygen Meter-HSOM has a specially designed sampling configuration with an inbuilt pump and timer switch and an ultrasensitive oxygen sensor that makes it feasible to accurately measure oxygen contamination in the headspace flexible food packs or tin cans. The Model incorporates an adapted hypodermic needle to pierce the loose food packs and draw the gas using the inbuilt pump. In the case of headspace analysis of tin cans, Model HSOM when used with the tin can piercer device provides the headspace analysis of % oxygen in the tin can of heights up to 380 mm. The high vacuum pump is designed to educts the headspace atmosphere of low internal pressure. Models can work on 220 VAC mains supply or on Rechargeable Battery. This portable instrument is available with a digital readout 0-25% 02 range and 0.1 % oxygen in steps with front adjustments for zero, calibration & sampling of the headspace gas.

Applications :

The food packaging industry uses modified atmospheres to improve shelf life and quality of nuts, wafers, snack foods, oils, skimmed milk, milk powder and many other packaged food products within various food packages such as soft packs pouches, tin cans or bottles. Model HSOM provides an analysis method for headspace oxygen that helps quality control by determining the residual oxygen in the headspace. Model HSOM helps to adjust the speed of nitrogen gas while packaging correctly. The simplicity of operation of Model HSOM makes it ideal for quick routine measurements and repetitious laboratory studies.

Technical Specifications:

Display : 3 and Digit LCD 12 mm high

Range : 0 - 0.25%

Resolution : 0.1%

Accuracy : +2% at constant temperature

Power : Rechargeable batteries/ 230VAC Mains Supply

Sensor type : Electrochemical

Sensor life : Two years of expected life

Working temp. : 5-45C

Recorder Output : 0-1 V (Battery operated models)

Size : 195 x 98 x 155 mm depth

Weight : 1.5 kg approximately

Calibration : By ambient air or certified calibration gas

In-built Pump Version:

Gas Eduction : By internal pump

Pump Suction : Minimum 8" Hg Column

Flow : 0.5 Liter/Minute

Pump Timer : Adjustable between 3 to 30 Seconds (optional)

Features:

  • Internal Pump to draw a sample.
  • Easy to operate.
  • Adjustable timer for sample pump.
  • Portable, lightweight
  • Ultrasensitive Oxygen Sensor
  • Tin can pierce press & stand available with hardened needles.

Accessories:

  • Carrying case For Inst., Charger & Accessories,
  • Panel mounting clamps For Inst., Charger & Accessories
  • Hypodermic syringe Three nos. Needles and one lock valve.
  • Self-Adhesive pads 500 Nos. cut pieces of foam for flexible packs
  • Battery charger For Rechargeable Battery operated models, only

Additional Information:

Delivery Time : 4 weeks

View Complete Details

Toxic Gas Analyser

33,000 - 35,000 / piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Condition New
  • Application Industrial Use
  • Feature Accuracy, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Stable Performance
  • Number Of Flower Gas Analyzers
  • Availability 0-5kg
  • Country of Origin India
  • Detected gas CO, O2, SO2, CO2, O3, NH3, H2S, HCL, ETO, Cl2, NO, NO2, COCl2, HCN, N2H4, H2, ASH3, PH3, CS2, VOC

Introduction:

GAS ANALYSERS TGA-1 accurately measures the concentration of a particular gas in parts per million (ppm)/parts per billion (ppb)/%. These gas analyzers use electrochemical/NDIR/ PID/Pallister sensors which have an enviable reputation for reliability, stability, and rugged design having an output linearly proportional to the concentration level of the gas.

Applicatioins:

Gas Analysers TGA-1 find application in - Process Control, Quality Control, Area Surveillance Safety in work areas of Factories and Research institutions.

Technical specifications:

Display : Display 16 x 2 LCD with Back Light

Working temp : 0-50C

Accuracy : + 1% FS at constant temperature

Size & Weight : 225 x 200 x 120 mm deep & 1.5 Kg

Technology : Electrochemical/NDIR/PID/Pallister

Data : USB Output (Optional)

Downloading : 4-20 mA Recorder Output

Recorder O/P : RS485 MODBUS RTU

Drift : 1% FS as per 6 months

Enclosure : Table Top ABS

Data Storage : In-built 100 readings (in auto sample mode)

Power Supply : 230 V AC, 50Hz, Single phase, 5 Amps, Stabilized. Optional: rechargeable battery

Alarm : Visual & audible, settable thro range. Low battery alarm also with Relay (SPDT) Output

Flow Indicator : 0 2 LPM provided.

Response Time : 3 to 15 Sec < T90 at 2080%RH

Features:

  • One alarm audible & visual. User can Set Alarm with a setpoint view.
  • Alarm relay SPDT with NO, C, and NC for online models. 4-20 mA & RS485 MODBUS for On-line models.
  • Power 180230 VAC OR Rechargeable battery option available (to be specified in the order).
  • Portable models are offered with the INBUILT PUMP & FLOW INDICATOR option to draw sample gas.
  • Easy accessible Key Function: Escape, Enter, Up, Down.
  • OPTIONS for PORTABLE instruments only Internal pump with suction of 4Hg Column and flow of 2 LPM Rechargeable 12 V battery with charger & Low Battery Alarm. Accessories: Carrying Case, battery charger, 1-meter tube.
  • OPTIONS for ON LINE instruments only Panel Mount Enclosure. Accessories: Carrying Case, Panel Mounting clamps, 1-meter tube.
  • OPTIONS for Sensor mounting Either internal with an internal pump OR surface mounting as diffusion on the instrument. Externally on the end of a cable in diffusion mode only
View Complete Details

FGD-X Fixed Gas Detector

30,000 / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Application Gas leak detector
  • Feature Saving Power, Waterproof
  • Country of Origin 220V
  • Number Of Flower Gas Detector
  • Accuracy +1 % at constant temperature
  • Country of Origin India
  • Size 120 x 120 x100 mm deep
  • Display 128x64 Transflective (visible both during day and night) LCD with backlight
  • Sensor type Electrochemical/Catalytic Pellistor

Introduction:

The FGD-X is a Microcontroller-based Gas leak detector for detecting Flammable Gas Hazards, Toxic Gas Hazards and Asphyxiant (Oxygen Deficiency) Hazards. It is a Single Point Wall Mounted Instrument work on 220 VAC main supply and has a sensor fitted at the end of a cable. They use an IP 55 enclosure for the electronics as standard.

Applications: They are used for continuous surveillance single point monitoring toxic or explosive gas in workplaces or enclosed spaces in hazardous, explosive or toxic gas conditions & environments.

Features:

Two Alarms, audible and visual (separate LEDs + alerts on display), along with inhibit, acknowledge and reset options.

Alarms are settable as manual or auto reset type (Latching or non-latching)

Two potential free relay contacts for external use.

Separate Confidence flash LED to know that equipment is working properly.

4 switch operation using Magnetic Pen (contact-less operation).

Data Outputs (Optional): Modbus RS485, 4-20 mA.

Technical Specifications:

Parameter Description

Display : 128x64 Transflective (visible both during day and night) LCD with backlight

Sensor type : Electrochemical/Catalytic Pellistor

Working Temperature & Humidity : 0 - 55C 5 - 95 %RH

Accuracy : +1 % at constant temperature

Range : 0-100

Resolution : 0.1 ppm

Overall size : 120 x 120 x100 mm deep

Recorder output : 4-20 mA, RS485 Modbus

Relay Rating : 220V AC, 1A, resistive load

Power supply : 220 VAC, 50 HZ

View Complete Details

DAMS Data Acquisition And Management System

1.65 Lakh / piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Condition New
  • Application Remotely visualizing real time data on PC & Smart Mobile phones. Real Time Data Transmission & Analy
  • Number Of Flower Data Acquisition System
  • Country of Origin India

Introduction:

This device is used for Real Time Data Transmission (current format) to Cloud Server of CPCB & SPCB by M to M methodology with IoT based next generation featured. Remotely visualizing real time data on PC & Smart Mobile phones. This DAMS series comprises of advanced data-logging devices for real-time environment monitoring.

Application:

Remotely visualizing real time data on PC & Smart Mobile phones. Real Time Data Transmission & Analysis tool to find pollutants trends. Life time licenses relevant software.

Features:

  • Remote monitoring.
  • WebFRONT Web SCADA Cloud gateway.
  • Easy configurator with inbuilt Web User Interface (Web UI).
  • MODBUS RTU RS-485 & MODBUS Ethernet/IP.
  • File Transfer Protocol (FTP) to other server and USB data recording.
  • Cloud server connectivity.
  • Alerts: SMS, Email.
  • Signal Scaling.
  • DAMS series comprises of advanced data- logging device for real-time environment monitoring.
  • Rugged design for rough Industrial conditions.
  • Real-time data collection.
  • Data-quality indication.
  • Transfer to Central Server Portal (New Guidelines).
  • Over-The-Air (OTA) upgrades.
  • Remote configurable as IoT based technology.
  • Internal 3000 records storage
View Complete Details

PPH-01 Online PH Monitoring System

1 Lakh / Unit Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Automatic Grade Fully Automatic
  • Power 230V AC
  • Application Tank Monitoring
  • Number Of Flower Ph Monitoring System, Gas Detection Systems
  • Availability 0-5kg
  • Total Carbohydrate 1yrs
  • Country of Origin India
  • Conditon New
  • Accuracy +0.1 % ± 1 digit
  • Display 4-digit High Brightness non-fading 0.56” LED
  • IP code IP55
  • Size (mm) 100*100*75
  • Range 0-14 pH
  • Total Weight 2.5 kg

Introduction:

PRIMA Industrial pH Monitoring System, Model PPH-01 is designed for precision ON LINE pH measurements in Industrial processes. An instrument to measure pH in waste water, sewage water, production line. It is Microprocessor based analyzer to read and transmit the pH level by receiving the direct signal from the measuring electrode.

Application:

The pH measurement system is designed to perform in a wide spectrum of applications that require the use of different types of pH electrodes, wide temperature range of processes and the special needs in processes that are partially of fully nonaqueous. With a correct choice of electrode for the application, this instrument will perform under the most demanding of applications and environments. In many processes, the display is required to be separated from the electrode. Comprehensive range of pH electrodes and Electrode holders for a variety of applications is available. These include Gel Filled, Polymer Gel filled, High temperature electrode for samples up to 130 C, liquid filled electrodes for non-aqueous samples, electrode modules with ATC in Corrosion resist RYTON body. A range of pH electrode calibration and maintenance solutions to get the best performance from your pH system. Method: Direct measuring Combined pH Electrode, Solution Ground.

Features:

External Transmitter near electrode for areas where Instrument is at distant location.
Automatic Selection of HIGH & LOW set points in case of incorrect setting.
Choice of Panel Mount, Wall Mount & Flameproof enclosures.

Additional Information:

Delivery Time : 4 weeks

View Complete Details

PISO-19 In-Situ Oxygen Analyzer

65,000 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name PRIMA
  • Condition New
  • Application Oxygen Analyser
  • Feature Accuracy, Digital Display, Highly Competitive
  • Accuracy ±2% F.S
  • Country of Origin India
  • Detected gas O2
  • Range Measurement of Oxygen 0 to 25%v, Resolution: 0.1%v
  • Suitable for Temperature (Flue Gas) 0-600°C / 1000°C (customizable)
  • Suitable for Velocity 0 - 40 m/s
  • Response Time <5s
  • Signal Output 1 x 4-20 mA, isolation (Optional) 1 x MODBUS RS485
  • Material of Probe inserted 316L steel, Probe length depends on Duct OD & ID
  • Purging Auto Purge available.
  • Calibration Auto calibration with purge air
  • Environmental Temperature 0-60 degree centigrade
  • Storage Humidity 0-85 % RH
  • Measurement Standards Meets the measurement requirements of EN14181
  • Approvals TUV Certified for Design and Quality TUV Certified device as per EN/IEC Standards

Introduction:

PISO-19 Oxygen Analyzer is a new generation of In-situ Online Monitoring instrument, which can monitor the Oxygen of Flue Gas in various typical application in a long time under severe conditions. It is very crucial parameter to calculate the combustion efficiency controller.PISO-19 Zirconia Oxygen sensor is equipped with blowback unit. Compared with conventional integrated monitor, it can measure Oxygen with settable range from 0 to 50%. LCD display measure data and signals to controller. Smaller size ensures convenient moving, installation and maintenance.

Application:

Apply to Oxygen Measurement in industries of high energy consumption like Power, Ceramic and Steel. Glass industries having facilities of Furnace, Boilers, Hot Air Generator, Thermic Fluid heater etc.

Features:

  • In-situ method, hence directly to insert probe in flue gas duct.
  • Ultra-high-precision oxygen sensor achieves the measurement of accurate %.
  • Large LCD display to operating unit provides good interface.
  • Timing back blow time Strengthen output signal protection

Specifications:

ParameterDescription
Range Measurement of Oxygen 0 to 25%v, Resolution: 0.1%v
Suitable for Temperature (Flue Gas) 0-600C / 1000C (customizable)
Suitable for Velocity 0 - 40 m/s
Measuring Accuracy 2% F.S.
Response Time

View Complete Details

Spmms-c91 Continuous Stack Dust Pm Monitoring System

1.25 Lakh / piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Driven Type Electric
  • Condition New
  • Automatic Grade Automatic
  • Power Supply 110/230V AC, 50 Hz
  • Certification TÜV Certified As Per ISO 9001: 2015 For Design, Production And Quality
  • Number Of Flower Dust Monitoring System
  • Country of Origin India
  • Accuracy ±2% F.S at constant Temperature
  • Response Time 5 sec (T90)
  • Environmental Rating IP55 or IP65
  • Analog Output Isolated 4-20mA current
  • Digital Output RS485/RS232 MODBUS RTU

Introduction:

The PRIMA SPMMS-C91 is designed for Continuous Monitoring of Emission of Particulate Matters from the Stack. It can be widely used in continuous monitoring situations such as boilers, industrial furnaces, incinerator emissions, etc. The system offers reliability, flexibility, Simplicity of use and installation for application in The most corrosive and challenging environment. Measurement technique ensures stable Long-term operation with high accuracy and very Low drift. Engineered for ease & user friendly of maintenance and packaged for the industrial Environment. SPMMS series analyzers are simple to Install and trouble-free in operation. It can be either equipped with CEMS, or connected with dust monitoring network by a shared set of data acquisition and processing background.

Application:

Power generation boilers, Industrial furnaces, Industrial boilers in the thermal power, Iron and steel metallurgy, Petrochemical, Chemical, Cement production, Ceramics, Waste incineration, Wet Scrubber, Textile.

Features:

  • Fully integrated system in a single box- no moving parts or additional components required.
  • Low maintenance straightforward servicing without specialist skills.
  • Advance electronics and micro controller-based controller.
  • TV Certified for Quality of Design and Production of system.
  • TV Certified process as per EN/IEC standard.
  • Simple installation locate the analyzer anywhere, including outside locations.
  • IP55 level protected marshalling box panel.
  • In-House Indian Design considering Dust, Temperature and Humidity conditions.
  • All electronic with conformal coating to avoid atmospheric effects in harsh area.
  • Microprocessor LCD TFT display
View Complete Details

PEMAG-910 Electromagnetic Flow Meter

1.25 Lakh / piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name PRIMA
  • Material Cast Aluminium
  • Pressure 10 Kg/cm2 (more on request)
  • Operating Temperature 2-50°C
  • Accuracy + 0.5 – 0.2 % of F.S
  • Country of Origin India
  • Display Digital

Introduction:

Electromagnetic flowmeters accurately measure the flow rate of conducting liquids or slurries flowing in closed pipes. Due to its simple and proper design, the electromagnetic flowmeter is an obstruction less & maintenance-free instrument in place of the conventional mechanical flow measuring device. The use of Pulsed DC technology offers the highest ability & better measuring accuracy in the form of 4-20mA DC output linearly proportional to the volumetric flow.

Applications:

Effluent Treatment Plants, Sewage Treatment plants, Water Supply Schemes, Steel & Aluminium, Pulp & Paper, Chemical & Fertilizers Food & Drugs, Pumps Valve, Calibration Lab, Dairy Industry, Corrosive Liquid, Municipal Corporation, Sugar Industry, Textile Industries, Dyeing & Printing, Hotels & Resorts, Water Parks, and Buildings & Infrastructure.

Features:

  • Size DIN 10 to DIN 3000 NB pipeline.
  • High accuracy better than + 0.5% of reading.
  • Zero Pressure Drop.
  • Suitable for High Viscosity Conductive Liquids.
  • Digital Flow rate/ Totalizer Indication/ Batching system.
  • Isolated Transmitting Output 4-20 mA.
  • No Grounding Ring is required.
  • Minimum Upstream & Downstream Straight Length.
  • Compact & Rugged, IP 65 Protection.
  • Remote Flow Indication Totalizer/ batching System through GSM Modem.
View Complete Details

AADM-B19 Continuous Ambient Air Dust Monitor - Betaray

55,000 - 60,000 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name PRIMA
  • Condition New
  • Certification TÜV Certified for design & quality
  • Availability 50 Kgs
  • Country of Origin India
  • Power Stabilized 1Ø phase, 230VAC, 5 Amps, 50Hz
  • Accuracy ± 2% at constant temperature
  • Size 600 x 600 x 600 mm
  • Display Alpha numeric LCD with backligh
  • Enclosure Weather proof IP 55 Level protected with Air-Conditioner.

Introduction:

The AADM-B19 is designed for Continuous Monitoring of Environment parameter specifically Particulate Matters. Particulate measurements produced due to emissions of vehicle traffic, energy production plants, heating systems and various industrial plants. Mapping an area with respect to the concentration of the atmospheric particulate. Suitable to work in Mobiles vans, Fixed Station, On moving vehicles as cars, train, bus etc. This measuring system has been designed for making reliable continuous measurements without the presence of operators. AADM-B19 92

Capable of Monitoring:

PM 10-Inhalable Dust:
It is the fraction of airborne material which enters the nose and mouth during breathing and is therefore liable to deposition anywhere in the respiratory tract. The particle sizes of total inhalable dust are up to 100 microns.

PM 2.5-Thoracic Dust:
It is defined as those materials that are hazardous when deposited anywhere within the lung airways and the gas exchange region.

PM 1-Respirable Dust:
It is defined as that fraction of the dust reaching alveolar region of the lungs.

Application:

The Equipment is suitable for use for measurement of the dust concentrations present; in a specific location urban area, in a specific location industrial area, at working places, in the offices, in the transportation vehicles etc., in moving materials area, and inhaled by a person during a day.

Principle on which the Sensor works

Used air monitoring technique employing the absorption of beta radiation by solid particles extracted from air flow. So, the air is drawn from outside of the detector through an infinite (cycling) ribbon made from some filtering material so that the particles are collected on it. There are two sources of beta radiation placed one before and one after the region where air flow passes through the ribbon leaving particles on it; and there are also two detectors on the opposite side of the ribbon, facing the detectors. The sources intensity and detectors sensitivity being the same, the intensity of beta rays detected by one of detectors is compared to that of the other. Thus, one can deduce how much mass has the ribbon acquired upon being exposed to air flow; knowing the drain velocity, actual particle mass concentration in air could be assessed. The radiation source be a gas chamber, filled with a pieces of 14C-rich polymer plastic, such as PMMA. Detector is simply a GeigerMueller counter. The particulate matter content measured is affected by the moisture content in the air, unfortunately, hence adopted with appropriate sampling head.

Features:

  • Meets the measurement requirement of EN 481 / DIN ISO 7708 standards and rules, CPCB Guidelinesfor workplace monitoring.
  • Designed as per US EPA Standard along with Sampling head as per EPA standard.
  • The microprocessor controller-based technology helps the system to perform accurately & efficiently.
  • The methodology used for Dust Concentrations measurement, expressed as PM-10 monitoring in the air is using.
  • Beta Ray Attenuation Principle with using external cutting impactors-based sampling head.
  • Very reliable, simple design to ensure accurate service life.
  • No need of shelter.
  • Long term Calibration stability.
  • The detector allows to assess cumulative mass concentration of suspended particulate matter (PM) in the ambient air.
  • Sampling head is with heater, hence avoid humidity effect on sensor.
  • High resolution reading at affordable cost.
  • Pre-heating time required.
  • Non-Corrosive components.
  • Measurement at automatic Hourly cycles.
View Complete Details

CAAPEMS-91/91O Continous Ambient Air Pollution Monitoring System

1.50 Lakh / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name PRIMA
  • Condition New
  • Automatic Grade Semi Automatic
  • Number Of Flower Ambient Air Quality Monitoring Equipment
  • Availability 5 Kgs
  • Country of Origin India
  • Accuracy ± 2% at constant temperature
  • Display TFT, Multi color LCD Graphic Display
  • Operating temperature 0°C to + 50°C
  • Power Supply 220V 50Hz, 15 Amp, 500W (without panel air conditioner)

Introduction:

The CAAPEMS-91 is designed for Continuous Monitoring of Environment parameters such as Particulate Matters, Gases, Odor, Temperature, Humidity and Atmospheric Pressure in the air. The system has a facility to incorporate Meteorological parameter measurements.

Application:

The system provides an immediate measurement of the concentration of Odor, Gases & Dust present in a specific location, both urban and industrial, for evaluating the environmental safety degree in a working area like Wastewater Treatment Plants, Composting, Solid Waste Management, Agrofood, Chemical & Petrochemical, Pulp & Paper, Industrial Livestock, and Mining. It can also be used on moving vehicles such as mobile laboratories, trains etc.

Features:

  • The system is designed for Continuous Monitoring Application to be installed open to sky at the prescribed monitoring location.
  • Water & Dust Proof IP66 level protected enclosure.
  • The Microprocessor & Logic Controller based technology helps the system to perform accurately & efficiently.
  • The gas sensing technology is linear; hence need only two-point calibration which is calibrated by sensor manufacturers in laboratories under controlled concentration and ambient conditions. The final readings displayed are calculated after temperature compensation calculation formula.
  • The methodology used for Real Time Odor, Gases & Dust Concentrations measurement in the air are Gas Sensing Electrochemical Sensor, Semiconductor Sensor, Thermal Conductivity Sensor, Zirconium Dioxide Sensor, Catalytic Combustion Sensor etc
  • An instantaneous reading of the level of pollutants is displayed at the location of system installed (Optional feature).
  • Laser scattering allows immediate and continuous measurement of fine particle present in the air both with respect to their number, their dimensions and their concentration in g/m3.
  • Meets the measurement requirement of EN 481.
  • It offers a facility for interfacing to an IoT based Real Time & Date Acquisition, Monitoring and FTP interface protocol to transfer RTD data to PRIMA centralized station data Network via Ethernet / 3G, 4G (GSM/GPRS) Interface.
View Complete Details

OGA-1 Oxygen Gas Analyzer

45,000 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name PRIMA
  • Condition New
  • Availability 1.5 Kgs
  • Detected gas O2
  • Power 230 V AC, 50Hz, Single phase, 5 Amps, Stabilized. Optional: rechargeable battery
  • Dimensions 225x200x120 mm deep
  • Display Display 16 x 2 LCD with Back Light
  • Accuracy + 1% FS at constant temperature
  • Alarm Visual & audible, settable thro’ range. Low battery alarm also with Relay (SPDT) Output
  • Response time 3 to 15 Sec < T90 at 20~80%RH
  • Drift ± 1% FS as per 6 months
  • Operating temperature 0-50°C

Introduction:

Oxygen Gas Analyzers OGA-1 accurately measures the concentration of Oxygen gas in parts per million (ppm)/parts per billion (ppb)/%. These gas analyzers use O2 sensors, which have an enviable reputation for reliability, stability, and rugged design, having an output linearly proportional to the concentration level of the gas.

Application:

Oxygen Gas Analyzers OGA-1 find application in; Process Control, Quality Control, Area Surveillance, Safety in work areas of Factories and Research Institutions.

Features:

  • One alarm audible & visual user is settable with a setpoint view.
  • Alarm relay SPDT with NO, C, and NC for online models.
  • 4-20 mA & RS485 MODBUS for On-line models.
  • Power 180230 VAC OR Rechargeable battery option available (to be specified in the order).
  • Portable models are offered with the INBUILT PUMP & FLOW INDICATOR option to draw sample gas.
  • Easy accessible Key Function: Escape, Enter, Up, Down.
View Complete Details

PTV-91 Stack Gas FTP Monitor

50,000 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Condition New
  • Application Stack Monitoring
  • Feature Accuracy, Easy To Fit, Measure Fast Reading, Robust Construction
  • Display Type Digital
  • Temperature Range Thermocouple, 1200°C
  • Accuracy ±2% F.S
  • Signal Output 3 x 4-20mA, isolation 1 x MODBUS RS485 (Optional) 1 x MODBUS RS232 (Optional)
  • Purge Auto Purging

Introduction:

The PTV-91 Module is a new generation of the Online emission Monitoring instrument, which can monitor the Temperature, Pressure, Velocity/Flow rate of Flue Gas in various typical applications in a long time under severe conditions. These are very crucial parameters to calculate the pollutant emission in the OCEMS. PTV-91 has Low/high precision micro Differential Pressure/Static Pressure Sensor with the equipped blowback unit. Compared with conventional integrated monitor, it can measure Pressure Value also. TFT WQVGA Color Graphical display measure data and signal, convenient reading and debugging; smaller size ensures convenient moving, installation and maintenance.

Application:

Measures Velocity, Temperature, Pressure, Flow of high Temperature, Humidity and dusty gas in a variety of boiler, furnace flue and mine exhaust pipes.

Features:

  • Ultra-high-precision pressure sensor achieves the measurement of low-flow (2m/s).
  • Optional: TFT color display operating unit for good human-machine interaction interface.
  • Timing of back blow, velocity field parameters Pitot tube coefficient and stack radius can be set.
  • Overvoltage protection effectively avoids pressure sensor being damaged and reducing operating cost.
  • Strengthen output signal protection
View Complete Details

AADM-19 Continuous Ambient Air Dust Monitor - Laser

55,000 / Piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name PRIMA
  • Condition New
  • Number Of Flower Ambient Air Quality Monitoring Equipment
  • Availability 5 Kgs
  • Country of Origin India
  • Power Stabilized, 1Ø phase, 230V AC, 5Amps
  • Accuracy +2% at constant temperature
  • Display 20x4 Alphanumeric LCD with backlight
  • Operating temperature 0°C to + 50°C
  • Enclosure FRP, Weatherproof IP 65 level protected & UL Certified.
  • Data Output RS485 MODBUS RTU (with PRIMA DAMS)

Introduction:

The monitoring unit is an indigenously manufactured for Continuous Monitoring of Environment parameter such as Particulate Matters in the air. This measuring system has been designed for making reliable continuous measurement without the presence of operators.

Application:

The System is designed for continuous monitoring application to be installed open to sky at the prescribed monitoring location.

Features:

  • The microprocessor-based technology helps the system to perform accurately & efficiently.
  • The methodology used for Real-Time Dust Concentrations measurement, expressed as PM-10, PM2.5 & PM 1.0 monitoring in the air and classifying them depending on their dimensions is Laser Scattering without external impactors.
  • Laser scattering allows immediate, continuous and Real-Time measurement of fine particles present in the air concerning their concentration in ug/m3.
  • Meets the measurement requirement of EN 481.
  • Very reliable, Low maintenance, No need for shelter.
  • Long term Calibration stability.
  • Insensitive to vibrations.
  • High resolution reading at an affordable cost.
  • No preheating time required.
  • Non-Corrosive components.
  • Instantaneous Data Logging.
View Complete Details
Tell Us What are you looking for? Will call you back