Microprocessor Based Static ELR 4-12A

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / Mobile Operating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/Steel Plant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
View Complete Details

Microprocessor Based Static ELR 50-2000mA

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • Test & Reset Facility for testing healthiness of the relay
  • Tamper proof polycarbonate cover in the front.
  • High Barrier connector at rear for easy termination and safety standards.
View Complete Details

Switch Mode Power Supply Based Battery Charger

The design is based on the fly back topology. High switching frequency makes thecomponents sizes to decrease, and hence reduction in the size. The efficiency of the unitis greater than 80%. The input voltage is applied to the transformer primary which isswitched at high frequency controlled by the feedback. The feedback is incorporatedusing Opto - isolators. The output of the transformer is rectified using proper rectifier diodes.The output is further smoothened with the use of smoothing inductors to reduce the rippleto the desired level.

Specification
  • Wide input voltage tolerance
  • High efficiency
  • Overload, short circuit & reverse polarity protection
  • Very low load & line regulation
  • Output power up to 480W
  • Rugged, reliable and tropicalised design
  • Work with natural convection cooling(No forced air cooling required)
  • The operating temp. is -5 C to +55 C
  • Input and output terminations and LED indications
View Complete Details

Microprocessor Based Static

Prok dvs make Definite Time / Instantaneous Static Earth Fault Relay (EFR) is a current sensing device which is tropicalised, professionally designed and tested for protection of Generators, Transformers and Feeders. Prok dvs make Static Definite Time & Instantaneous Earth Fault Relay (EFR) can be employed with various earth fault protective schemes, which are explained in brief with figures. The magnitude of the earth fault current depends on the fault impedance and invariably the fault impedance for earth fault is higher than that for phase faults, hence the earth fault current is low compared to the phase fault currents. The fault impedance depends on the system parameter and also on type of earthing. The neutral may be solidly grounded, grounded through resistance or reactance.

Specification
  • Static Device
  • Compact, Reliable with Aesthetic Value
  • Rugged, Robust and Tropicalised design
  • Consistent repeat accuracy
  • Wide Current Operating range
  • LED Indication for Healthy & Fault Status
  • Manual Reset & Low Burden on CT Secondary
View Complete Details

Automatic Changeover Cum Current Limiter

Whenever the load current exceeds the Set limit, power is instantaneously switched off and resets automatically after 9 seconds. If the over load still exists, this cycle is (3Sec ON & 6Sec OFF) repeated for every 9 sec. ACCL will enter into Lock Out mode after 5 ON & OFF cycles, if over load of the DG still persists. User has to manually Reset the ACCL.
Note: However tripping cycles can be configured according to user choice

View Complete Details

Auto Source Changeover Cum Current Limiter

Microprocessor based Auto Source Changeover cum Current Limiter with Dual Source Energy Recording. It has Contactor logic incorporated with Electrical and Mechanical Interlock with current ratings upto 63A

Specification
  • Model PACCL-3Phase with Energy
  • Current ratings 1Amps to 63Amps continuous duty when load on EB/DG
  • While monitoring the Generator supply, it allows only a limited load and functions as Load limiter as per desired current (Factory set)
  • Whenever Load Current exceeds the present limit, power is automatically switched off and on automatically after 9 seconds and trips again if the overload still exists this cycle(3sec ON & 6sec OFF) is repeated every 9 sec, ACCL will enter into LOCK OUT mode after 5 ON & OFF cycles if overloading of DG still exists.
  • On resumption of EB mains, ACCL automatically changes from DG to EB and allows full current. ACCL comes out of LOCK OUT mode when EB resumes. The unit can be Reset manually by RESET switch
  • The ON/OFF cycles can be set according to customer requirements (optional) . If the unit has entered LOCK OUT mode due to OV/UV, the unit has to be reset manually.
View Complete Details

Intelligent PF Controller

RISC architecture based, intelligent state-of-the-art PNPF Prok dv's make DigitalMicrocontroller based Intelligent Automatic Power Factor Controller/Regulator/CorrectionRelay (APFCR) with on-line monitoring of line PF through industrial grade back-lit LCD Display.The Unit uses one of the tried and time tested intelligent algorithms to switch the capacitorbanks, in a most optimum combination in a shortest time for any dynamic load conditionswithout the need to select the complicated switching sequences by the user.

Specification
  • User entered parameter is stored in non-volatile memory (EEprom)
  • CT Ratio & System Voltage user selectable through key board display
  • Independent of Frequency
  • Most Optimum combination obtained through advanced control programming
  • RISC architecture dedicated Microcontroller based
  • Target pf 0.80lag to 0.90 lead selectable through key board display
  • Auto/Manual mode
  • No complicated setting procedure
  • User friendly interface
View Complete Details

1 Phase

Application :

  1. Electrical Distribution Control & Relay Panel
  2. Power Control Centre
  3. Motor Control Centre
  4. Generator Control Panels
  5. Test Benches and Laboratory Equipments
  6. Wind Energy and Co-Generation Plants
  7. Air Conditioning/Refrigeration Plants
Specification
  • Accuracy class 0.5/1.0
  • Solid State version
  • Built in transducers
  • Built in Selector Switch or without selector switch
  • Compact in size with Aesthetic value
  • 7 segment red LED Display
  • Tropicalised Design and time tested
  • Low power consumption
View Complete Details

Microprocessor Based Din Mount 1-10A

Prok dvs make Microcontroller Based Motor Protection Relay PD-MMPR-303 uses the state-of-the-art Microcontroller based measurement techniques for providing protection for Motors up-to 75HP. The comprehensive protection features of the relay make it ideal for Motor protection. The heart of the relay is microcontroller based reliable hardware with special algorithms to calculate the tripping time. The relay continuously monitors the Three Phase Currents to build the thermal replica of the Motor. This thermal replica is used to protect the Motor against Thermal over Loads.

Specification
  • Thermal Over Load Protection
  • Single Phasing /Phase Fail Protection
  • Phase Reversal Protection
  • Unbalance Protection
  • Earth Fault Protection
  • Locked Rotor Protection
  • Under Current Protection
  • Instantaneous Short Circuit protection during Run mode
View Complete Details

Microprocessor Based Static ELR

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static EFR

Specification:

  • Auxiliary Voltage -110V/230V/415V/550V, AC 50Hz48/110/220 VDC.
  • Frequency -50Hz
  • Neutral or Summation CT Rated Current-In -1A or 5A (Factory Set)
  • Burden on CT -
View Complete Details

Ammeter

  1. Electrical Distribution Control & Relay Panel
  2. Power Control Centre
  3. Motor Control Centre
  4. Generator Control Panels
  5. Test Benches and Laboratory Equipments
  6. Wind Energy and Co-Generation Plants
  7. Air Conditioning/Refrigeration Plants
Specification
  • Accuracy class 0.5/1.0
  • Solid State version
  • Built in transducers
  • Built in Selector Switch or without selector switch
  • Compact in size with Aesthetic value
  • 7 segment red LED Display
  • Tropicalised Design and time tested
  • Low power consumption
View Complete Details

Microprocessor Based Digital ELR 30mA-3A

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages.

Prok dv's make Digital microprocessor/microcontroller based Earth Leakage Relays (ELR) withCore Balance Current Transformer (CBCT / ZCT) are used to detect leakage currents inelectrical power systems. ELR transmits a signal to activate the trip coil of theMCCB/ACB/OCB/CONTACTOR in the event of earth leakage resulting in automatic isolationof the load. ELR have been widely used and accepted because of field adaptability andare economic.

Specification
  • Digital Microprocessor / Microcontroller based compact design.
  • Continuous monitoring and display of set value and measured value of leakage current.
  • 8 character 2 line LCD displays with back-lit.
  • Test & Reset facility.
  • CBCT / ZCT connection monitoring facility.
  • True RMS measurement of leakage current.
  • Trip Circuit Failure indication.
  • Immune to harmonics and transients.
  • Serial RS. 485 communication port with Modbus Protocol (optional).
  • Tropicalized and rugged design.
  • Transducer Output- (4 mA-20mA) (optional).
View Complete Details

L.T. Control Panels

  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / MobileOperating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/SteelPlant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static ELR 300mA-3000mA

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / Mobile Operating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/Steel Plant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
View Complete Details

Microprocessor Based Static ELR 30mA

  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / MobileOperating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/SteelPlant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
Specification
  • Fixed or variable current sensitivity by Dip Switch selection
  • Consistent reliability with accuracy.
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static ELR 1-8A

Earth Leakage Current give rise to generation of heat and result in progressive failure of insulation, which leads to earth faults sparking flashovers, deterioration of earthing and finally results into catastrophic fires which destroys costly equipments, gadgets and precious lives. It is therefore essential to detect earth leakage current well before they cross the threshold limits and isolate the circuit in the event of leakages. Conventional over current and short circuit protection device are not designed detect earth leakage currents.

Prok dvs make Earth Leakage Relay (ELR) with Core Balance Current Transformer( CBCT / ZCT) are used to detect the leakage current in an Electrical Power System. Earth Leakage Relay (ELR) transmits a signal to activate the trip coil of the MCCB/ACB/OCB CONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electrical power system. Earth leakage relay (ELR) and core balance current transformer (CBCT / ZCT) have been widely used and accepted because these have field adaptability and are economic.

Specification
  • Test & Reset Facility for testing healthiness of the relay
  • Tamper proof polycarbonate cover in the front.
  • High Barrier connector at rear for easy termination and safety standards.
  • LEDs for visual indication of fault.
  • Fixed or variable current sensitivity by Dip Switch selection
  • Consistent reliability with accuracy.
View Complete Details

AC Voltage Monitor

Prok dvs AC Voltage Monitor is a microprocessor based voltage monitoring
and supervision relay for polyphase systems. It can monitor both Under and
Over Voltage conditions in the system. Both Under and Over Voltage are
associated with definite time tripping characteristics. It has wide range for
UV and OV settings as well as operating characteristics on the occurence
of fault.

View Complete Details

Automatic Changeover

  • On resumption of EB mains, ACCL automatically changes from DG to EB and allows full current. ACCL comes out of LOCK OUT mode when EB resumes. The unit can be Reset manually by RESET switch
  • The ON/OFF cycles can be set according to customer requirements (optional) . If the unit has entered LOCK OUT mode due to OV/UV, the unit has to be reset manually.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Prok Devices Private Limited (Prok Devices Private Limited)
  • B-80, 2nd & 3rd floor, Rajajinagar Industrial Estate (KSSIDC),4th Main Road, Rajajinagar 6th Block, Bengaluru, Bangalore, Karnataka - 560010
  • Share us via
List of Other Products by Prok Devices Private Limited from Bangalore, Karnataka.
Post Buy Requirement

Other Products / Services #5881558

Microprocessor Based Static ELR 4-12A

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / Mobile Operating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/Steel Plant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
View Complete Details

Microprocessor Based Static ELR 50-2000mA

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • Test & Reset Facility for testing healthiness of the relay
  • Tamper proof polycarbonate cover in the front.
  • High Barrier connector at rear for easy termination and safety standards.
View Complete Details

Switch Mode Power Supply Based Battery Charger

The design is based on the fly back topology. High switching frequency makes thecomponents sizes to decrease, and hence reduction in the size. The efficiency of the unitis greater than 80%. The input voltage is applied to the transformer primary which isswitched at high frequency controlled by the feedback. The feedback is incorporatedusing Opto - isolators. The output of the transformer is rectified using proper rectifier diodes.The output is further smoothened with the use of smoothing inductors to reduce the rippleto the desired level.

Specification
  • Wide input voltage tolerance
  • High efficiency
  • Overload, short circuit & reverse polarity protection
  • Very low load & line regulation
  • Output power up to 480W
  • Rugged, reliable and tropicalised design
  • Work with natural convection cooling(No forced air cooling required)
  • The operating temp. is -5 C to +55 C
  • Input and output terminations and LED indications
View Complete Details

Microprocessor Based Static

Prok dvs make Definite Time / Instantaneous Static Earth Fault Relay (EFR) is a current sensing device which is tropicalised, professionally designed and tested for protection of Generators, Transformers and Feeders. Prok dvs make Static Definite Time & Instantaneous Earth Fault Relay (EFR) can be employed with various earth fault protective schemes, which are explained in brief with figures. The magnitude of the earth fault current depends on the fault impedance and invariably the fault impedance for earth fault is higher than that for phase faults, hence the earth fault current is low compared to the phase fault currents. The fault impedance depends on the system parameter and also on type of earthing. The neutral may be solidly grounded, grounded through resistance or reactance.

Specification
  • Static Device
  • Compact, Reliable with Aesthetic Value
  • Rugged, Robust and Tropicalised design
  • Consistent repeat accuracy
  • Wide Current Operating range
  • LED Indication for Healthy & Fault Status
  • Manual Reset & Low Burden on CT Secondary
View Complete Details

Automatic Changeover Cum Current Limiter

Whenever the load current exceeds the Set limit, power is instantaneously switched off and resets automatically after 9 seconds. If the over load still exists, this cycle is (3Sec ON & 6Sec OFF) repeated for every 9 sec. ACCL will enter into Lock Out mode after 5 ON & OFF cycles, if over load of the DG still persists. User has to manually Reset the ACCL.
Note: However tripping cycles can be configured according to user choice

View Complete Details

Auto Source Changeover Cum Current Limiter

Microprocessor based Auto Source Changeover cum Current Limiter with Dual Source Energy Recording. It has Contactor logic incorporated with Electrical and Mechanical Interlock with current ratings upto 63A

Specification
  • Model PACCL-3Phase with Energy
  • Current ratings 1Amps to 63Amps continuous duty when load on EB/DG
  • While monitoring the Generator supply, it allows only a limited load and functions as Load limiter as per desired current (Factory set)
  • Whenever Load Current exceeds the present limit, power is automatically switched off and on automatically after 9 seconds and trips again if the overload still exists this cycle(3sec ON & 6sec OFF) is repeated every 9 sec, ACCL will enter into LOCK OUT mode after 5 ON & OFF cycles if overloading of DG still exists.
  • On resumption of EB mains, ACCL automatically changes from DG to EB and allows full current. ACCL comes out of LOCK OUT mode when EB resumes. The unit can be Reset manually by RESET switch
  • The ON/OFF cycles can be set according to customer requirements (optional) . If the unit has entered LOCK OUT mode due to OV/UV, the unit has to be reset manually.
View Complete Details

Intelligent PF Controller

RISC architecture based, intelligent state-of-the-art PNPF Prok dv's make DigitalMicrocontroller based Intelligent Automatic Power Factor Controller/Regulator/CorrectionRelay (APFCR) with on-line monitoring of line PF through industrial grade back-lit LCD Display.The Unit uses one of the tried and time tested intelligent algorithms to switch the capacitorbanks, in a most optimum combination in a shortest time for any dynamic load conditionswithout the need to select the complicated switching sequences by the user.

Specification
  • User entered parameter is stored in non-volatile memory (EEprom)
  • CT Ratio & System Voltage user selectable through key board display
  • Independent of Frequency
  • Most Optimum combination obtained through advanced control programming
  • RISC architecture dedicated Microcontroller based
  • Target pf 0.80lag to 0.90 lead selectable through key board display
  • Auto/Manual mode
  • No complicated setting procedure
  • User friendly interface
View Complete Details

1 Phase

Application :

  1. Electrical Distribution Control & Relay Panel
  2. Power Control Centre
  3. Motor Control Centre
  4. Generator Control Panels
  5. Test Benches and Laboratory Equipments
  6. Wind Energy and Co-Generation Plants
  7. Air Conditioning/Refrigeration Plants
Specification
  • Accuracy class 0.5/1.0
  • Solid State version
  • Built in transducers
  • Built in Selector Switch or without selector switch
  • Compact in size with Aesthetic value
  • 7 segment red LED Display
  • Tropicalised Design and time tested
  • Low power consumption
View Complete Details

Microprocessor Based Din Mount 1-10A

Prok dvs make Microcontroller Based Motor Protection Relay PD-MMPR-303 uses the state-of-the-art Microcontroller based measurement techniques for providing protection for Motors up-to 75HP. The comprehensive protection features of the relay make it ideal for Motor protection. The heart of the relay is microcontroller based reliable hardware with special algorithms to calculate the tripping time. The relay continuously monitors the Three Phase Currents to build the thermal replica of the Motor. This thermal replica is used to protect the Motor against Thermal over Loads.

Specification
  • Thermal Over Load Protection
  • Single Phasing /Phase Fail Protection
  • Phase Reversal Protection
  • Unbalance Protection
  • Earth Fault Protection
  • Locked Rotor Protection
  • Under Current Protection
  • Instantaneous Short Circuit protection during Run mode
View Complete Details

Microprocessor Based Static ELR

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static EFR

Specification:

  • Auxiliary Voltage -110V/230V/415V/550V, AC 50Hz48/110/220 VDC.
  • Frequency -50Hz
  • Neutral or Summation CT Rated Current-In -1A or 5A (Factory Set)
  • Burden on CT -
View Complete Details

Ammeter

  1. Electrical Distribution Control & Relay Panel
  2. Power Control Centre
  3. Motor Control Centre
  4. Generator Control Panels
  5. Test Benches and Laboratory Equipments
  6. Wind Energy and Co-Generation Plants
  7. Air Conditioning/Refrigeration Plants
Specification
  • Accuracy class 0.5/1.0
  • Solid State version
  • Built in transducers
  • Built in Selector Switch or without selector switch
  • Compact in size with Aesthetic value
  • 7 segment red LED Display
  • Tropicalised Design and time tested
  • Low power consumption
View Complete Details

Microprocessor Based Digital ELR 30mA-3A

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages.

Prok dv's make Digital microprocessor/microcontroller based Earth Leakage Relays (ELR) withCore Balance Current Transformer (CBCT / ZCT) are used to detect leakage currents inelectrical power systems. ELR transmits a signal to activate the trip coil of theMCCB/ACB/OCB/CONTACTOR in the event of earth leakage resulting in automatic isolationof the load. ELR have been widely used and accepted because of field adaptability andare economic.

Specification
  • Digital Microprocessor / Microcontroller based compact design.
  • Continuous monitoring and display of set value and measured value of leakage current.
  • 8 character 2 line LCD displays with back-lit.
  • Test & Reset facility.
  • CBCT / ZCT connection monitoring facility.
  • True RMS measurement of leakage current.
  • Trip Circuit Failure indication.
  • Immune to harmonics and transients.
  • Serial RS. 485 communication port with Modbus Protocol (optional).
  • Tropicalized and rugged design.
  • Transducer Output- (4 mA-20mA) (optional).
View Complete Details

L.T. Control Panels

  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / MobileOperating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/SteelPlant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
Specification
  • Consistent reliability with accuracy.
  • Fixed or variable current sensitivity by Dip Switch selection
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static ELR 300mA-3000mA

Earth Leakage Current give rise to generation of heat and result in progressive failure ofinsulation, which leads to earth faults sparking flashovers, deterioration of earthing and finallyresults into catastrophic fires which destroys costly equipments, gadgets and precious lives.It is therefore essential to detect earth leakage current well before they cross the thresholdlimits and isolate the circuit in the event of leakages. Conventional over current and shortcircuit protection device are not designed detect earth leakage currents.

Prok dv's make Static Earth Leakage Relay (ELR) with Core Balance Current Transformer ( CBCT/ ZCT) are used to detect the leakage current in an Electrical Power System. Static EarthLeakage Relay (ELR) Transmits a signal to activate the trip coil of the MCCB/ACB/OCBCONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electricalpower system. Static earth leakage relay (ELR) and core balance current transformer (CBCT /ZCT) have been widely used and accepted because these have field adaptability and areeconomic.

Specification
  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / Mobile Operating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/Steel Plant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
View Complete Details

Microprocessor Based Static ELR 30mA

  • Frame Leakage protection for L.T. Control Panels and switch boards.
  • Earth Leakage protection for Feeders / Motors / Generators / Transformers / MobileOperating Equipments.
  • Protection for hazardous sensitive environments like Oil Refineries/ Cement Plant/SteelPlant /Chemical Platforms/Pulp industries and General Electrical Distribution.
  • Protection for Mining & Control Engineering
Specification
  • Fixed or variable current sensitivity by Dip Switch selection
  • Consistent reliability with accuracy.
  • LEDs for visual indication of fault.
  • High Barrier connector at rear for easy termination and safety standards.
  • Tamper proof polycarbonate cover in the front.
  • Test & Reset Facility for testing healthiness of the relay
View Complete Details

Microprocessor Based Static ELR 1-8A

Earth Leakage Current give rise to generation of heat and result in progressive failure of insulation, which leads to earth faults sparking flashovers, deterioration of earthing and finally results into catastrophic fires which destroys costly equipments, gadgets and precious lives. It is therefore essential to detect earth leakage current well before they cross the threshold limits and isolate the circuit in the event of leakages. Conventional over current and short circuit protection device are not designed detect earth leakage currents.

Prok dvs make Earth Leakage Relay (ELR) with Core Balance Current Transformer( CBCT / ZCT) are used to detect the leakage current in an Electrical Power System. Earth Leakage Relay (ELR) transmits a signal to activate the trip coil of the MCCB/ACB/OCB CONTACTOR in the event of Earth leakage, resulting in automatic isolation of the electrical power system. Earth leakage relay (ELR) and core balance current transformer (CBCT / ZCT) have been widely used and accepted because these have field adaptability and are economic.

Specification
  • Test & Reset Facility for testing healthiness of the relay
  • Tamper proof polycarbonate cover in the front.
  • High Barrier connector at rear for easy termination and safety standards.
  • LEDs for visual indication of fault.
  • Fixed or variable current sensitivity by Dip Switch selection
  • Consistent reliability with accuracy.
View Complete Details

AC Voltage Monitor

Prok dvs AC Voltage Monitor is a microprocessor based voltage monitoring
and supervision relay for polyphase systems. It can monitor both Under and
Over Voltage conditions in the system. Both Under and Over Voltage are
associated with definite time tripping characteristics. It has wide range for
UV and OV settings as well as operating characteristics on the occurence
of fault.

View Complete Details

Automatic Changeover

  • On resumption of EB mains, ACCL automatically changes from DG to EB and allows full current. ACCL comes out of LOCK OUT mode when EB resumes. The unit can be Reset manually by RESET switch
  • The ON/OFF cycles can be set according to customer requirements (optional) . If the unit has entered LOCK OUT mode due to OV/UV, the unit has to be reset manually.