Industrial Floorings either bearing heavy load or general loadings
APPLICATION PROCEDURE
Laitance deposits on new concrete are best removed by light grit blasting, mechanical scrabbling or grinding.
All surfaces to be treated with EPFLOOR MM2 should be primed with PRIMER 25.
Mix EPFLOOR MM2 flooring as per pre-weighed packs (base, hardener, aggregate & color pack) which are ready for immediate on-site mixing.
It should be spread to the required thickness using a serrated trowel with care taken not to overwork the resin, spreading evenly and slowly. Immediately after laying, the material should be rolled, using a spiked nylon roller to remove slight trowel marks and to assist air release.