Laboratory Equipments #342554

Stainless Steel Inner Chamber

  •  Work Space  24 "(L)x 24"(D) x 24"(H)
  •  Temp. Range  - 20o C to 100 oC
  •  Temp. Tolerance  + / - 1 oC
  •  Temp. Control  95% +/- 3% temp. range 25 oC to 60 oC

 Specifications :
 1  Work Space  24 "(L)x 24"(D) x 24"(H)
 2.  Temp. Range  - 20o C to 100 oC
 3  Temp. Tolerance  + / - 1 oC
 4  Temp. Control  95% +/- 3% temp. range 25 oC to 60 oC
 5  Temp. Sensor  By solid state digital temperature Indicator Controller for dry & wet bulb with  PT-100
 6  Power  440 V + / - 5%, 3 phase neutral 50 Hz at 15 amp/phase stabilized AC supply
 7  Construction
 Interior
 Exterior
 Insulation
 Door
 Gasket
 Hinges & Latches
 Mounting
 Double wall type with
 22 swg Stainless Steel
 20 Swg CRCA MS sheets with powder coating
 1 00 mm glass wool insulation
 Full front opening door double walled insulated & interior lined with stainless steel
 Double gasket one on chamber and one on the door
 Heavy duty hinges with locking system
 Trolley mounting type with castors
 8  Overall dimesnsions  32 " (L) x 36" (D) x 60 " (H)














View Complete Details

Hot Air Ovens

  • Work Space  0.5 X 0.5 X 0.5 Mt to 2 X 2 X 2 Mt
  •  Temp. Range  Ambient + 10 to 200 Deg. oC
  •  Temp. Tolerance  +/- 1 Deg. oC
  •  Temp. Control  By Digital Temp. Controller oC
  •  Temp. Sensor  PT 100
  •  Power  230 / 440 VAC
Optional Features:
PID Controllers
On Delay Timer
Specimen Trays
View Complete Details

Humidity Chambers

  •  Work Space  0.5 X 0.5 X 0.5 Mt to 1 X 1 X 1 Mt
  •  Temp Range  + 10 to 100 Deg. oC
  •  Temp. Tolerance  +/- 1 Deg. oC
  •  Temp. Control  By Digital Temp. Controller for Dry & Wet Build
  •  Temp. Sensor  PT 100
  •  Humidity  95 +/- 3 % temp. Range 25 to 60 Deg. oC
  •  Power  230 / 440 VAC
Optional Features:
PID controllerInspector window with Two Pane Glass, Heater and Lamp.Port holes of 25 mm dia for specimen wiring.Chamber On delay timer.Specimen trays.Electrical terminals through wall
Systems Provided :
Air-Circulation Systems1/20 Hp capacity continuous rated 230 Volts, single phase AC operated motor along with 12" dia fan has been provided for uniform temperature and humidity condition inside the chamber.

Heating SystemsLow surface loading inconel tube heaters having capacity 500 watts-2nos. Has been provided to add heat inside the chamber. All the heaters are mounted in the conditioning space and will operate in the black zone.

Humidity SystemsLow pressure moisture generator tank has been provided to generate the moisture and add humidity in the chamber. 2 KW capacity immersion heater having 1 V4 BSP threading has been provided inside the moisture generator tank. The moisture generator tank has been provided along with low water level controller with mechanical float type refilling arrangement.

Control Panel and wiringSeparate control panel provided on the top of the chamber which incorporate all the indicating and monitoring instruments with control switches, MCB'S, contactors, indicating lamps etc. All the wiring will be done as per IS color code with channel type wiring.

Utilities Provideda. Chamber drainb. Viewing window 30x30cms 2 pane glass with low wattage heater & manually operated wiperc. Chamber interior lightd. Port hole 25mm dia 1 no.e. Terminal panel-6 nos. 5 amp capacityf. 30 Lts capacity S/S tank provided on the top for water storage

Safety Protections Provideda. MCB's for heatersb. Over temperature safety cut-off with audio visual alarm.c. Low water level indication with audio visual alarm

Water requirement30 Lts/day dematerialized water during the humidity test

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Manufacturer of Laboratory Equipments from Pune, Maharashtra by Refricon HVAC Systems
Post Buy Requirement
RH
Pune, Maharashtra, India
Add Review

Laboratory Equipments #342554

Stainless Steel Inner Chamber

  •  Work Space  24 "(L)x 24"(D) x 24"(H)
  •  Temp. Range  - 20o C to 100 oC
  •  Temp. Tolerance  + / - 1 oC
  •  Temp. Control  95% +/- 3% temp. range 25 oC to 60 oC

 Specifications :
 1  Work Space  24 "(L)x 24"(D) x 24"(H)
 2.  Temp. Range  - 20o C to 100 oC
 3  Temp. Tolerance  + / - 1 oC
 4  Temp. Control  95% +/- 3% temp. range 25 oC to 60 oC
 5  Temp. Sensor  By solid state digital temperature Indicator Controller for dry & wet bulb with  PT-100
 6  Power  440 V + / - 5%, 3 phase neutral 50 Hz at 15 amp/phase stabilized AC supply
 7  Construction
 Interior
 Exterior
 Insulation
 Door
 Gasket
 Hinges & Latches
 Mounting
 Double wall type with
 22 swg Stainless Steel
 20 Swg CRCA MS sheets with powder coating
 1 00 mm glass wool insulation
 Full front opening door double walled insulated & interior lined with stainless steel
 Double gasket one on chamber and one on the door
 Heavy duty hinges with locking system
 Trolley mounting type with castors
 8  Overall dimesnsions  32 " (L) x 36" (D) x 60 " (H)














View Complete Details

Hot Air Ovens

  • Work Space  0.5 X 0.5 X 0.5 Mt to 2 X 2 X 2 Mt
  •  Temp. Range  Ambient + 10 to 200 Deg. oC
  •  Temp. Tolerance  +/- 1 Deg. oC
  •  Temp. Control  By Digital Temp. Controller oC
  •  Temp. Sensor  PT 100
  •  Power  230 / 440 VAC
Optional Features:
PID Controllers
On Delay Timer
Specimen Trays
View Complete Details

Humidity Chambers

  •  Work Space  0.5 X 0.5 X 0.5 Mt to 1 X 1 X 1 Mt
  •  Temp Range  + 10 to 100 Deg. oC
  •  Temp. Tolerance  +/- 1 Deg. oC
  •  Temp. Control  By Digital Temp. Controller for Dry & Wet Build
  •  Temp. Sensor  PT 100
  •  Humidity  95 +/- 3 % temp. Range 25 to 60 Deg. oC
  •  Power  230 / 440 VAC
Optional Features:
PID controllerInspector window with Two Pane Glass, Heater and Lamp.Port holes of 25 mm dia for specimen wiring.Chamber On delay timer.Specimen trays.Electrical terminals through wall
Systems Provided :
Air-Circulation Systems1/20 Hp capacity continuous rated 230 Volts, single phase AC operated motor along with 12" dia fan has been provided for uniform temperature and humidity condition inside the chamber.

Heating SystemsLow surface loading inconel tube heaters having capacity 500 watts-2nos. Has been provided to add heat inside the chamber. All the heaters are mounted in the conditioning space and will operate in the black zone.

Humidity SystemsLow pressure moisture generator tank has been provided to generate the moisture and add humidity in the chamber. 2 KW capacity immersion heater having 1 V4 BSP threading has been provided inside the moisture generator tank. The moisture generator tank has been provided along with low water level controller with mechanical float type refilling arrangement.

Control Panel and wiringSeparate control panel provided on the top of the chamber which incorporate all the indicating and monitoring instruments with control switches, MCB'S, contactors, indicating lamps etc. All the wiring will be done as per IS color code with channel type wiring.

Utilities Provideda. Chamber drainb. Viewing window 30x30cms 2 pane glass with low wattage heater & manually operated wiperc. Chamber interior lightd. Port hole 25mm dia 1 no.e. Terminal panel-6 nos. 5 amp capacityf. 30 Lts capacity S/S tank provided on the top for water storage

Safety Protections Provideda. MCB's for heatersb. Over temperature safety cut-off with audio visual alarm.c. Low water level indication with audio visual alarm

Water requirement30 Lts/day dematerialized water during the humidity test