Our Complete range of products are POWER NEEDLE EXPANSION BOLTS, Expansion Bolts, Power Hook Expansion Bolts, POWER BULLET EXPANSION BOLTS and POWER SHEILD EXPANSION BOLTS.
Size Prefference mmM8 X 50, M8 X 70, M10 X 75, M10X 100
Bolt Dia(D) mm8 10 12 16
Pull out loads are for M200 cement concrete.The recommended distance between the edge of any platform and thedrilling position is a maximum of six times the diameter of the hole.Factor of safety recommended is of : Uniform load = 4, Shock loads = 8.Non standard sizes and H.T.Bolts can be made on request.SWL is with Factor of safety of 1 : 4 for static loads.Right to alter design dimensions remains with the manufacturer.
Size Prefference mmM10 X 100, M12 X 100, M12 X 150, M16 X 100 , M16 X 150
Bolt Dia(D) mm10 12 16 20
Pull out loads are for M200 cement concrete.The recommended distance between the edge of any platform and thedrilling position is a maximum of six times the diameter of the hole.Factor of safety recommended is of : Uniform load = 4, Shock loads = 8.Non standard sizes and H.T.Bolts can be made on request.SWL is with Factor of safety of 1 : 4 for static loads.Right to alter design dimensions remains with the manufacturer.
Pull out loads are for M200 cement concrete.The recommended distance between the edge of any platform and thedrilling position is a maximum of six times the diameter of the hole.Factor of safety recommended is of : Uniform load = 4, Shock loads = 8.Non standard sizes and H.T.Bolts can be made on request.SWL is with Factor of safety of 1 : 4 for static loads.Right to alter design dimensions remains with the manufacturer.
Size Prefference mmM8 X 50, M10 X 50, M10 X 75, M12 X 60, M12 X 75
Bolt Dia(D) mm8 10 12 16
Pull out loads are for M200 cement concrete.The recommended distance between the edge of any platform and thedrilling position is a maximum of six times the diameter of the hole.Factor of safety recommended is of : Uniform load = 4, Shock loads = 8.Non standard sizes and H.T.Bolts can be made on request.SWL is with Factor of safety of 1 : 4 for static loads.Right to alter design dimensions remains with the manufacturer.
Size Prefference mmM6 X45, M8 X 60, M10 X 70, M12 X 80
Bolt Dia(D) mm6 8 10 12
Pull out loads are for M200 cement concrete.The recommended distance between the edge of any platform and thedrilling position is a maximum of six times the diameter of the hole.Factor of safety recommended is of : Uniform load = 4, Shock loads = 8.Non standard sizes and H.T.Bolts can be made on request.SWL is with Factor of safety of 1 : 4 for static loads.Right to alter design dimensions remains with the manufacturer