Post Buy Requirement
REVTI ELECTRONIC INDUSTRIES
Rewari, Haryana, India
gstGST : 06AJCPD6470A1ZT Verified Add Review

Thermocouple Cables #524921

Rtd Cable

rtd cables manufactured by revti electronics industries are used as connecting lead wire between rtd sensor and temperature indicator device. Rtd cables are made in 2 core, 3 core, 4 core and 6 core configurations. 3 cores being the most commonly used configuration.

construction :-

rtd cables are made in three common constructions for making them suitable for different situations. These are ptfe/ptfe insulated. This is the most common construction. In this the cores are insulated with ptfe and then cores are twisted and jacketed with ptfe/ptfe/fg. In this construction cores are of ptfe and jacket is of fiber glass braid. This is used when rtd cable has to be installed in high temperature environment.

ptfe/spc/ptfe :-

in this construction, a spc wire braid shield is provided between twisted cores and jacket. This type of cable is used where higher accuracy is required. The current and voltage signals in rtd cables are of very small magnitude and can get affected by external electromagnetic noises produced by external devices such as motors, electronic equipments etc. Near the cable. The spc shield is grounded from one end and this protects the signals in the cable from these external noises.

construction :-

rtd cables are made in five common constructions

1. Ptfe /ptfe2. Ptfe/ptfe/fg3. Ptfe/ptfe/ss4. Ptfe/ptfe/spc5. Ptfe/ptfe/fg/ss

View Complete Details

RTD Cables

  • Material Ptfe
  • Length 100 Meter
  • Packing Type Roll
  • Temperature 65c To 200c
  • Insulation Yes
  • Power/Voltage 400 V

Relying on our experience in the industry gained over years, we, as a Manufacturer, Exporter & Supplier of RTD Cables have positioned us in the top string of the industry.  They are applied as connecting lead wire between RTD sensor and temperature indicator device. The available configurations are 2 core, 3 core, 4 core and 6 core. The most common configuration is 3 cores.

ConstructionRTD Cables are made in three common constructions for making them suitable for different situations. These are PTFE/PTFE insulated. This is the most common construction. In this the cores are insulated with PTFE and then cores are twisted and jacketed with PTFE/PTFE/FG. In this construction cores are of PTFE and jacket is of Fiber glass braid. This is used when RTD cable has to be installed in high temperature environment.

PTFE/SPC/PTFEIn this construction, a SPC wire braid shield is provided between twisted cores and jacket. This type of Cable is used where higher accuracy is required. The current and voltage signals in RTD Cables are of very small magnitude and can get affected by external electromagnetic noises produced by external devices such as motors, electronic equipments etc. near the cable. The SPC Shield is grounded from one end and this protects the signals in the cable from these external noises.

Construction

  • RTD Cables are made in five common constructions
    • PTFE /PTFE
    • PTFE/PTFE/FG
    • PTFE/PTFE/SS
    • PTFE/PTFE/SPC
    • PTFE/PTFE/FG/SS
View Complete Details

Thermocouple Cable

Thermocouple wires & cables are used to make or extend signals from a thermocouple. Thermocouple wire is used in a thermocouple from the sensing point to the cold junction compensation point (or reference point).

It is the difference in the millivolt output from the sensing point to the reference point that provides the temperature measurement. Different thermocouple types require different alloy wire combinations.

Some of the more popular thermocouple wire & cable types include

Type E (Chromel/Constantan), Type J (Iron/Constantan), Type K (Chromel/Alumel), andType T (Copper/Constantan)

LIMITS OF ERROR :-

Initial Calibration Tolerances as per ASTM E230 & ANSI MC 96.1Tolerance Reference Junction ( 0C)Limits of Error in Thermocouple Wire

Limits of Error in Thermocouple Wire
Type of Wire Temperature Range Standard Grade
T (-200°C to 370°C ) ±1.8 (1) or ±0.75%
J (0°C to 760°C) ±4 (2.2) or ±0.75%
E (-200°C to 870°C) ±3.1 (1.7) or ±0.50%
K (-200°C to 1260°C) ±4 (2.2) or ±0.75%
N (-200°C to1260°C) ±4 (2.2) or ±0.75%
     
View Complete Details

Thermocouple Cables

  • Type Thermocouple Cables
  • Material Plastic
  • Length 2.5mtr, 3.5mtr, 3mtr
  • Color Multi Colour
  • Application Industries
  • Power Source Electric
  • Feature Durable, Fine Finished, High Strength
  • Tenmperature 0-100 Deg C, 100-200 Deg C, 1000-1100 Deg C, 200-300 Deg C, 300-400 Deg C

Determined to present the utmost quality, we are involved in offering Thermocouple Cables. They are applied for making or extending signals from a thermocouple. They are also applied in a thermocouple from the sensing point to the cold junction compensation point (or reference point). It provides the temperature measurement as it is the difference in the millivolt output from the sensing point to the reference point. Different alloy wire combinations are applicable in different thermocouple types.


Thermocouple Wire & Cable Types

  • Type E (Chromel/Constantan),
  • Type J (Iron/Constantan),
  • Type K (Chromel/Alumel), and
  • Type T (Copper/Constantan)


Limits of Error

  • Initial Calibration Tolerances as per ASTM E230 & ANSI MC 96.1
  • Tolerance – Reference Junction ( 0oC)
  • Limits of Error in Thermocouple Wire

Specification

Type of Wire Temperature Range Standard Grade
T (-200oC to 370oC ) ±1.8 (1) or ±0.75%
J (0oC to 760oC) ±4 (2.2) or ±0.75%
E (-200oC to 870oC) ±3.1 (1.7) or ±0.50%
K (-200oC to1260oC) ±4 (2.2) or ±0.75%