Post Buy Requirement
RI
Nashik, Maharashtra, India
Add Review

Other Products / Services #3637440

Cts Wire

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Low Tension Current Transformers

  • System Voltage 720V maximum
  • Ambient temperature -25°C to +40°C
Current transformers convert an alternating current usually high in to a proportional lower one,
depending on their use. Measurement type CTs are required to transform the primary current, at various classes of
accuracy, as specified by the class designation, over a current range from 1 to 120 percent of its rated primary ratio.
The design of this type of transformer requires the inclusion of a core and winding which will when connected to its
rated burden; perform within the limits of error as indicated by the standards specification. It is an advantage for a
measurement type transformer to saturate above this range, which provides a protection against damage to
instruments by limiting the secondary current when surge currents or faults appear in the primary circuit.
View Complete Details

DC Shunts

  • Voltage 50mV, 60mV, 75mV & 150mV
  • temperature range -10…+55 ºC
The RISH Shunts are available from 1A upto 3000A with an accuracy of 0.5% & 1%. Standard voltage drop is 50mV, 60mV, 75mV & 150mV. Intermediate current ratings, other voltage outputs, better accuracy and purpose built shunts can be supplied.
View Complete Details

Analog Ammeter

  • Panel thickness < 40 mm
The moving iron, panel meters, DE 487296144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages in the usual frequency range of 15.100Hz. Moving iron meters indicate rms-values practically independent of waveform even of high harmonic. Error of indication may occur for extreme waveforms (e.g. phase gating controls) & for frequencies above 100kHz. waveforms ( e.g. phase gating controls) and for frequencies above 100kHz. These meters offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). For CT operated ammeters, dials can be fitted based on CT ratio. Front window glass and bezel can be easily replaced.
View Complete Details

Moving Iron Ammeter

  • frequency range 15.400Hz, 15.100Hz.
  • Dimension 48mm x 48mm, 72mm x 72mm, 96mm x 96mm, 144mm x 144mm
The moving iron panel meters, DE 487296144 housed in moulded
polycarbonate cases are suitable for the measurement of AC
currents for frequency range of 15.400Hz and voltages in the
frequency range of 15.100Hz.
Moving iron meters indicate rms-values practically independent of
waveform even of high harmonics. Error of indication may occur for
extreme waveforms (e.g. phase gating controls) & for frequencies
above 100KHz.
These meters offer several advantages in switchboards and
Generating Set Panels. Number of meters can be mounted in a
Panel cut out Mosaic mounting). For CT operated ammeters, dials
can be fitted based on CT ratio. Glass and bezel can be easily
replaced.
View Complete Details

RS232 CONVERTER

  • Weight < 50 g
  • Bezel size 48 mm x 24 mm
The unit is a port powered two-channel (half-duplex) RS-485
to RS-232 converter. It converts the balanced halfduplex RS-485
signals to TD and RD RS-232 lines. The unit is powered from the
RS-232 data and handshake lines whether the lines are high or
low. An external power supply can be connected to two terminals
on the RS-485 connector if no handshake lines are available.

Although the converter uses handshake lines to power itself,
no handshaking is required to control the RS-485 driver.
The RS-485 driver is automatically enabled during each
spacing state on the RS-232 side. During the marking or idle
state, the RS-485 driver is disabled and the data lines are held in
the marking state by the 4.7k ohm pull-up and pull-down
resistors. The value of these resistors may need to be changed
to a different value when termination is used in order to maintain
the proper DC bias during the idle state.
View Complete Details

Tap Position Indicator

  • Temperature ± 0.15% per 10 K
The purpose of the Tap position transducer is to convert tap position
of transformers to equivalent analogue output. Outputs can be given
as input to either RTU or indicator or recording instrument.
Input variable and measuring range are programmed with the aid of
a PC and the configuration software.
The device has one input channel and two independent out puts.
View Complete Details

Energy Management System

It helps to enhance your energy conservation and utility management efforts by regularly polling the data from Rishabh Multi Function Meters on a RS 485 serial communication system using MODBUS. The data is collected on one centralised computer (Master PC) from where it can be accessed remotely through LAN connection.RISHEMS (Energy Management System) is an ideal energy management solution for industries, manufacturing plants, shopping malls, commercial buildings or any situation where high amount of electricity is consumed.
View Complete Details

Rotary Cam Switch

  • Rated Insulation Voltage 440 690 690
ON-OFF Switches, Change over Switches, Multi-step Switches, Volt-Ammeter Switches
, Selector Switches, Mains Switching, Coolant Pumps
A focused standard range of Rish Cam series Rotary Cam
Switches cover most applications with different contact
designs, contact material and terminals allow their use as
control switches, instrumentation switches and motor control
switches, as well as in electronic circuitry and in aggressive
environment according to IECEN 60947-3 and VDE 0660
part 107.
View Complete Details

Annunciator Windows

  • Supply Voltage 18 - 90 VDC or 88 - 285V AC / DC.
Micro-controller based logic. Built in watchdog design to ensure fail safe operation. Facia windows with long life super bright white LEDs. Easily replaceable window legendsinscriptions. Wide input supply range (i.e 18 - 90 VDC 88 - 285V AC DC). Operation test function does not affect the status of the faults. Detection of momentary fault, which may have occurred while performing push button operation or operation test functions. Test function checks total system hardware. Self supervision Annunciator healthy condition or Annunciator fail Relay Contacts.
View Complete Details

Insulation Tester

The Agam AIT 501 is the 5KV Smart Digital Insulation resistance tester with diagnostic features like PI, DAR. Has selectable test voltages of 500V, 1000V, 2500V and 5000V & Insulation resistance measurement upto 1 TOhm. An compact tool for Insulation testing designed smartly.ITI series is a low voltage insulation tester which is best suited for testing motors, transformers, generators, switch gears, cables, house hold appliances, on-site maintenance and service departments.
View Complete Details

Instrument Transformers

Rish Protection class CTs are square & round type encapsulated with UL94V-0 approved polycarbonate.These CTs used for protection purpose (acc class 5P10, 10P10 etc)& features wide range of primary current ratings, Busbar sizes, case widths, having wall, cable, bus bar & DIN rail mountings
View Complete Details

Insulation Resistance Tester

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Signal Isolators

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Electrical Measuring Instruments

Automatic Dielectric constant, Dissipation. Factor & Resistivity Measurement. Inbuilt Printer facility for Test Report Printing. Easy storage of Data up to 250 Test Results.
View Complete Details

Cam Switches

The Wide range of Rish Rotary CAM switches cover most application with different contact design, contact material and terminals allow their use as control switches, instrumentation switches , motor control switches and Electronic circuitory.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mahender (Rishabh Instuments pvt. ltd.(100%eou))
  • F-31, Midc, Satpur, Nashik-422007, Maharashtra, India
  • Share us via
List of Other Products by Rishabh Instuments pvt. ltd.(100%eou) from Nashik, Maharashtra.
Post Buy Requirement
RI
Nashik, Maharashtra, India
Add Review

Other Products / Services #3637440

Cts Wire

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Low Tension Current Transformers

  • System Voltage 720V maximum
  • Ambient temperature -25°C to +40°C
Current transformers convert an alternating current usually high in to a proportional lower one, depending on their use. Measurement type CTs are required to transform the primary current, at various classes ofaccuracy, as specified by the class designation, over a current range from 1 to 120 percent of its rated primary ratio.The design of this type of transformer requires the inclusion of a core and winding which will when connected to itsrated burden; perform within the limits of error as indicated by the standards specification. It is an advantage for ameasurement type transformer to saturate above this range, which provides a protection against damage toinstruments by limiting the secondary current when surge currents or faults appear in the primary circuit.
View Complete Details

DC Shunts

  • Voltage 50mV, 60mV, 75mV & 150mV
  • temperature range -10…+55 ºC
The RISH Shunts are available from 1A upto 3000A with an accuracy of 0.5% & 1%. Standard voltage drop is 50mV, 60mV, 75mV & 150mV. Intermediate current ratings, other voltage outputs, better accuracy and purpose built shunts can be supplied.
View Complete Details

Analog Ammeter

  • Panel thickness < 40 mm
The moving iron, panel meters, DE 487296144 housed in moulded polycarbonate cases are suitable for the measurement of AC currents and voltages in the usual frequency range of 15.100Hz. Moving iron meters indicate rms-values practically independent of waveform even of high harmonic. Error of indication may occur for extreme waveforms (e.g. phase gating controls) & for frequencies above 100kHz. waveforms ( e.g. phase gating controls) and for frequencies above 100kHz. These meters offer several advantages in switchboards and Generating Set Panels. Number of meters can be mounted in a single Cut out (Mosaic mounting). For CT operated ammeters, dials can be fitted based on CT ratio. Front window glass and bezel can be easily replaced.
View Complete Details

Moving Iron Ammeter

  • frequency range 15.400Hz, 15.100Hz.
  • Dimension 48mm x 48mm, 72mm x 72mm, 96mm x 96mm, 144mm x 144mm
The moving iron panel meters, DE 487296144 housed in mouldedpolycarbonate cases are suitable for the measurement of ACcurrents for frequency range of 15.400Hz and voltages in thefrequency range of 15.100Hz.Moving iron meters indicate rms-values practically independent ofwaveform even of high harmonics. Error of indication may occur forextreme waveforms (e.g. phase gating controls) & for frequenciesabove 100KHz.These meters offer several advantages in switchboards andGenerating Set Panels. Number of meters can be mounted in aPanel cut out Mosaic mounting). For CT operated ammeters, dialscan be fitted based on CT ratio. Glass and bezel can be easilyreplaced.
View Complete Details

RS232 CONVERTER

  • Weight < 50 g
  • Bezel size 48 mm x 24 mm
The unit is a port powered two-channel (half-duplex) RS-485to RS-232 converter. It converts the balanced halfduplex RS-485signals to TD and RD RS-232 lines. The unit is powered from theRS-232 data and handshake lines whether the lines are high orlow. An external power supply can be connected to two terminalson the RS-485 connector if no handshake lines are available. Although the converter uses handshake lines to power itself, no handshaking is required to control the RS-485 driver.The RS-485 driver is automatically enabled during eachspacing state on the RS-232 side. During the marking or idlestate, the RS-485 driver is disabled and the data lines are held inthe marking state by the 4.7k ohm pull-up and pull-downresistors. The value of these resistors may need to be changedto a different value when termination is used in order to maintainthe proper DC bias during the idle state.
View Complete Details

Tap Position Indicator

  • Temperature ± 0.15% per 10 K
The purpose of the Tap position transducer is to convert tap positionof transformers to equivalent analogue output. Outputs can be givenas input to either RTU or indicator or recording instrument.Input variable and measuring range are programmed with the aid ofa PC and the configuration software.The device has one input channel and two independent out puts.
View Complete Details

Energy Management System

It helps to enhance your energy conservation and utility management efforts by regularly polling the data from Rishabh Multi Function Meters on a RS 485 serial communication system using MODBUS. The data is collected on one centralised computer (Master PC) from where it can be accessed remotely through LAN connection.RISHEMS (Energy Management System) is an ideal energy management solution for industries, manufacturing plants, shopping malls, commercial buildings or any situation where high amount of electricity is consumed.
View Complete Details

Rotary Cam Switch

  • Rated Insulation Voltage 440 690 690
ON-OFF Switches, Change over Switches, Multi-step Switches, Volt-Ammeter Switches, Selector Switches, Mains Switching, Coolant PumpsA focused standard range of Rish Cam series Rotary CamSwitches cover most applications with different contactdesigns, contact material and terminals allow their use ascontrol switches, instrumentation switches and motor controlswitches, as well as in electronic circuitry and in aggressiveenvironment according to IECEN 60947-3 and VDE 0660part 107.
View Complete Details

Annunciator Windows

  • Supply Voltage 18 - 90 VDC or 88 - 285V AC / DC.
Micro-controller based logic. Built in watchdog design to ensure fail safe operation. Facia windows with long life super bright white LEDs. Easily replaceable window legendsinscriptions. Wide input supply range (i.e 18 - 90 VDC 88 - 285V AC DC). Operation test function does not affect the status of the faults. Detection of momentary fault, which may have occurred while performing push button operation or operation test functions. Test function checks total system hardware. Self supervision Annunciator healthy condition or Annunciator fail Relay Contacts.
View Complete Details

Insulation Tester

The Agam AIT 501 is the 5KV Smart Digital Insulation resistance tester with diagnostic features like PI, DAR. Has selectable test voltages of 500V, 1000V, 2500V and 5000V & Insulation resistance measurement upto 1 TOhm. An compact tool for Insulation testing designed smartly.ITI series is a low voltage insulation tester which is best suited for testing motors, transformers, generators, switch gears, cables, house hold appliances, on-site maintenance and service departments.
View Complete Details

Instrument Transformers

Rish Protection class CTs are square & round type encapsulated with UL94V-0 approved polycarbonate.These CTs used for protection purpose (acc class 5P10, 10P10 etc)& features wide range of primary current ratings, Busbar sizes, case widths, having wall, cable, bus bar & DIN rail mountings
View Complete Details

Insulation Resistance Tester

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Signal Isolators

We are the manufacturer of our products. Some of our successful collaborations have been in manufacturing of Meter movements, Complete analogdigital meters, Multilayer SMT PCB assemblies, Digital meters sub-assemblies, Transformer cores, Coil windings, Small transformers, Punched metal components & Plastics injection moulding components.
View Complete Details

Electrical Measuring Instruments

Automatic Dielectric constant, Dissipation. Factor & Resistivity Measurement. Inbuilt Printer facility for Test Report Printing. Easy storage of Data up to 250 Test Results.
View Complete Details

Cam Switches

The Wide range of Rish Rotary CAM switches cover most application with different contact design, contact material and terminals allow their use as control switches, instrumentation switches , motor control switches and Electronic circuitory.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mahender (Rishabh Instuments pvt. ltd.(100%eou))
  • F-31, Midc, Satpur, Nashik-422007, Maharashtra, India
  • Share us via