  1. Microscope 3 Products available
  2. Spectrometers 7 Products available
  3. Sensors 4 Products available
  4. Others 91 Products / Services available

Other Products / Services #4533479

DFM Fluorides

Since 1992, LTS has been producing mil-spec compliant fluoride materials using the Direct Fluorination Method (DFM). LTS produces the highest quality fluorides available in the industry: Our novel DFM process allows for the production of extremely pure compounds with superior deposition properties Fluoride compounds produced via hydrofluoric acid (HF) reactions have impurities in the precipitated compound which are not easy to purify out. The Direct Fluoridation Method (DFM) is a specialized process defined by a high temperature plasma phase reaction of two or three components to increase the purity, viscosity, and consistency of the material. Then, secondary melting in fluorine gas atmosphere compensates for fluorine stoichiometry deficiencies The process is costly, cumbersome, and occasionally non-deployable in the cases of scandium fluoride (ScF3), aluminum fluoride (AlF3), cryolite (Na3AlF6), and a few other Rare Earth solutions of fluorides. LTS employs the DFM process in its production of ultra-high purity fluorides such as LaF3, GdF3, NdF3, LiScF4, CaF2, and MgF2 production for DUV-NIR applications, as well as YbF3, YF3, BaF2, CeF3, and our thorium fluoride (ThF4)replacement chemicals, solid solutions of YBC fluorides for IR applications.
View Complete Details

Battery Chemicals

As the world moves increasingly toward electricity based fuel, one important aspect is storage of that energy. Solar cells can only generate power during daylight hours and electric cars need to bring the electricity with them. The need for high performance batteries is higher than ever. Lithium ion batteries satisfy these needs and LTS supplies Lithium XYZ Oxide cathode materials in coin cells as well as our typical targets, powders, and shapeless pieces. When evaluating battery materials, the factors of importance are Energy Density: the amount of energy stored per unit weight or sometimes per volume. Specific Power: the speed you can deliver that energy. Lifespan: how many charge-discharge cycles can the battery sustain before chemical changes render it too weak to function. Cost: self explanatory. We should also consider Safety since lithium has a tendency to cause fires, Durability against high and low temperatures and time, and Charge Rate.
View Complete Details

ND-3800 NANO DOT Microspectrophotometer

  • Features Full spectrum absorbance analysis! 0.5 -2.0 µL sample size! No cells, no cuvette! No warm-up! Rapid measurement speed! Display the conventration d!irectly! No dilution for samples! Etc
NANO DOT Microspectrophotometer is a full spectrum (200-800 nm) spectrophotometer that is designed to measure concentration of DNA, RNA, protein, cell cultures, microarray samples. The system features CCD detector, a Xenon light source for long lamp life span and user friendly software.
View Complete Details

LDV System Fp40LD With Backward And Forward Scattering

The benefit of the new fp40 system is the capability to use backward AND forward scattering. If the optical access allows forward scattering you get more signal power. The light collector, developed by ILA, can be positioned with in the area the particles reflect the light, so there is more flexibility when using that system! The light collector can further more also be used seperately with our other LDV systems, so you can extend these systems too! As you need two optical accesses to use forward scattering, there is the possibility to use ourself-designed window chambers.
View Complete Details

External Cavity Diode Laser

The MOGLabs External Cavity Diode Laser offers research quality at a teaching-lab price. The ECD004 is robust and stable. When used with a MOGLabs Diode Laser Controller, mode-hop-free scanning range of up to 40GHz and linewidth below 100 kHz can be achieved using a low-cost uncoated 780 nm consumer diode. Diode replacement and re- alignment are easily accomplished by the end-user. Wavelength options extend from 370nm to 1064nm, and powers up to 200mW extra-cavity.
View Complete Details

Cateye Laser CEL002

  • Features Cateye filter design Fast piezo feedback Precision wavelength adjust High bandwidth direct modulation Microwave RF modulation Diode protection circuit and relay Etc.
The Cateye Laser from MOGLabs offers a new wist in external cavity diode lasers. A cateye reflector and ultranarrow filter replace the alignmentsensitive diffraction grating of conventional LittmanMetcalf and Litrow designs. The CEL002 is robust, stable, and acoustically inert. You can literally hit it with a hammer and it will stay locked, and it is inherently self aligning so you can tune tens of nanometers without having to realign. In combination with MOGLabs electronics, the linewidth can be well below 100 kHz. Most laser diode wavelengths are available, for example 393 to 400, 423 to 426, 460, 470, 638, 647, 671, 739 to 800, 820 to 895, 920 to 935, at powers up to 200mW extracavity
View Complete Details

CMOS Camera For PIV

The ILA.PIV.sCMOS camera comes with the scientific CMOS (sCMOS) imager, which enables image acquisition with high resolution, highest dynamical range available, high quantum efficiency and extremely low noise. With this camera, larger regions of interest are possible compared to the standard CCD cameras. Furthermore, what makes this camera suitable for PIV measurements is the very short interframing time and the integrated remote focus control. The standard edition of this camera has the EOS controller ring build-in, compatible with the Canon EF lenses. Hence, the lenss aperture and focus can be adjusted remotely.
View Complete Details

PIV Nano Camera

The camera with one of the highest quantum efficiency value in the PIV branch is also at the same time the smallest available camera. The small form factor is enabled through the design of the ultra-compact camera head and the integration of digital temperature compensation. The ILA.PIV.Nano camera comes with a 14 bit CCD image sensor, which is specially designed for low light applications in the visible spectral range.In addition to the pocket size dimensions and high-end performances, it also has a low price making it the perfect camera for smaller budgets.
View Complete Details

Diode Laser Controller

  • Features ntuitive controls with logarithmic response Auto-lock to centre of oscilloscope trace Two oscilloscope trace selector switches Eight functions in one unit: Etc
  • Applications Laser cooling and trapping Bose-Einstein condensation Quantum optics: squeezed light Electromagnetic
The MOGLabs Diode Laser Controller provides everything needed to drive your tunable external cavity diode laser (ECDL), and lock it to an atomic or other frequency reference. It offers a combination of impressive performance and ease-of-use: ergonomic and low-noise analogue controls, and intuitive front-panel selection of the signals you need to monitor. Our latest release simultaneously drives independent piezo tilt and translation.
View Complete Details

Subpicometric Optical Spectrum Analyzer

  • Specifications Optical Resolution (@3dB) 0.16 pm (20MHz @1550nm), Wavelength Range 1525 nm -1564 nm, Wavelength Accuracy + or - 2 pm, Spurious-free Dynamic Range1 >80 dB Etc.
  • Advanced functions Trace locking: uses an automatic or user-defined portion of the spectrum for reference to lock Etc
  • Applications Laser characterization Optical communications systems analysis Etc.
Subpicometric Optical Spectrum Analyzer (BOSA): BOSA's has unique combination of high-resolution and high dynamic-range brings a new range of measurement possibilities. The principle behind BOSA performance is stimulated Brillouin scattering (SBS), a non-linear optical effect produced by narrow-linewidth high-power light propagating through an optical medium that causes a very narrow filtering effect. BOSA technology is available in different models to fit all requirements and budgets
View Complete Details

Detector Responsivity Measurement System

Photodetector is the sensor that could convert the optical radiation signal to the electrical signal, which is made from photoemission material. Most of the photodetectors have strong spectral selectivity in a certain Spectrum area. Therefore, for one photodetector, different wavelengths have different spectral responsivity. The spectral responsivity is an important parameter index for characterizing the photodetector performance. And for the photoelectric material researching, the effect of some characteristics of the material itself such as doping density, lattice imperfection, absorption coefficient and minority carrier diffusion length on the photoelectric response capacity and the quantum efficiency could be obtained by measuring and analyzing the spectral responsivity data. That is very important and helpful for choosing better material and processing improvement.
View Complete Details

Laser Doppler Velocimetry (LDV)

  • Features Simple setup and alignment Long term stability High laser power transferred to the measurement volume High measurement accuracy No optical transmission fibers Etc.
We offering following types of Laser Doppler Velocimetry (LDV) A. Probefor Laser Doppler Velocimetry1. 2Dfp50 LDV probe2. fp50HeNe LDV probe3. fp50shift-532nm LDV probe4. fp50shift-660nm LDV probe5. fp50shift LDV beam combiner B. LDV Controller
View Complete Details

Time-Resolved IR Absorption Spectral Measurement System

Silicon carbide infrared radiation, wavelength range : 1-16mMirror with coating Au, improving Infrared light collection efficiencyInfrared Radiation is not only heating source but also Spectral transmittance measured radiation measure continuous spectral transmittance(absorption) of sample and time-resolved IR spectral
View Complete Details

UV-Vis Cuvettes

  • UV-VIS CUVETTES SPECIFICATIONS Window Thickness 1.25 mm Beam Height (Z-dimension) 8.5 mm and 11 mm Optical Glass Spectral Range 334 to 2500 nm Far UV Quartz Spectral Range 170 to 2700 nm NIR Quartz Spectral Range 220 to 3800 nm
We offer a selection of most popular cuvettes, vialsand cell holders used in the field of UV-Vis spectrophotometry.The cuvettes are manufactured using a heat fusing method whichensures that they are fused into a single homogeneous unit.Cuvettes are carefully annealed to remove any residual strainfor maximum cell integrity and physical strength. The cells can be used with most solvents and acidic solutions.Hydrofluoric acid (HF) and strong bases (pH >9) will negativelyaffect the cell surfaces.
View Complete Details

Grating Spectrographs

All of them are based on tried and trusted optical design which are optimized for maximum performance in the spectral range from 200 nm to 1100 nm, a range which can be analyzed using silicon based CCD-line detectors. The SGM100 uses a crossed Czerny-Turner design with optical traps which produces the least stray light and maximum optical resolution.
View Complete Details

Dual Light Source System

We are offering following dual light sources 1. LSD30T75 2. LST75SiN40 3. LST75SiC200 4. LST75SiC200LST75SiC20 1. LSD30T75 Deuterium & 75W Tungsten-halogen Dual Light Source System 30W Deuterium & 75W Tungsten-halogen Dual Light Source System(Power Supply Included).It can switch Deuterium & Tungsten-halogen freely. 2. LST75SiN40 Tungsten-halogen Light Source & 200W Carborundum Infrared Dual Light Source System 75W Tungsten-halogen Light Source & 200W Carborundum Infrared Dual Light Source System(Power Supply Included), You need Zolixscan software to drive light source switching.
View Complete Details

Spectral Transmittance Measurement System

The system measures protective glasses, helmets, protective masks and integral spectral transmittance Features Spectral Range 200-2200nmThe spectral transmittance ratio range: ()=0.1 0.9Tansmittance measurement system uncertainty1. U
View Complete Details

Absorption -Reflection Spectrophotometer

The ZLX-AS system is designed for high quality measurements with excellent stray light performance of absorption, transmission and reflectance from a wide range of solid and liquid samples. The system can be configured for use from the UV to IR spectral ranges by appropriate light source, monochromator grating and detector selection. Indeed by using an Omni-300 or longer focal length monochromator this system can continuously scan from UV to IR making it ideal for a range of samples that would be difficult to characterize with conventional spectrophotometer designs. The large sample chamber is fully modular and can accept a range of thin film, cuvette, and solid sample holders depending upon the application need and has fully adjustable optics to allow optimisation of the signal. Optional integrating spheres can be added if diffuse reflectance measurements are required.
View Complete Details

Confocal Raman Microspectrometer(New)

  • Characteristics High sensitivity: optical system transmittance >50%, latest advanced ultra-low noise scientific CCD detector, Multiple samples applicable: switchable micro- and macro- optical layouts Etc.
Finder Vista Series multifunction confocal Raman microscopy system, based on new designed confocal microscopy techniques, with the ultra-low noise CCD camera latest advanced for Raman detection, high-resolution spectrometer, attaining superior user friendliness and sensitivity. Finder vista series is the highest scalability micro spectroscopy system currently commercialized. It can be expanded into the workstation with functions such as PL spectra, fluorescence lifetime, highlow temperature spectra measurements etc. It is your best choice for scientific research.
View Complete Details

Laser Confocal Raman Microspectrometer

Laser Confocal Raman Microspectrometer ConfigurationFinder OneSpectral Range 180-5, 000cm-1 (high sensitivity) 90-5, 000cm-1 (low wavenumber)Resolution 2cm-1 (@585.25nm)Laser Options Standard532nm ( 100mWTEM00) Options: 325nm, 633nm, 785nm etc.Detector TE air-cooled CCD (LDC-DD)Effective Pixel 2000256Pixel Size 1515mQuantum Efficiency 95%@780nm Note: Above specification are 532nm laser, the specification will be different according to different laser wavelength.
View Complete Details

High Speed Cameras

The ideal 5-1000 fps camera for motion capture in life sciences, robotics and industrial automation. The XC-2 camera has been designed to give users the flexibility to create a recording environment which meets their particular application needs. Users can choose frame rates beginning at 5 fps up to a maximum of 1000 fps with multiple resolution choices up to 1920 x 1080. Using CMOS image sensor technology, the XC-2 camera delivers the perfect balance of light sensitivity, high recording speed, fast shuttering, and high resolution. Excellent image quality is achieved with a state-of-the-art 2.1 megapixel resolution sensor based on 5.5 m square pixels and 60% quantum efficiency. The extended spectral range makes the XC-2 camera ideal for biology and life science applications. Along with outstanding image quality, the XC-2 offers remarkably good Near Infrared (NIR) responsivity, a dynamic range up to 60 db, and global shutter technology to capture crisp images without blur or distortion. In addition, each individual pixel has a very high saturation capacity, resulting in an excellent signalnoise ratio for extremely sharp, highcontrast images. The compact size of the camera makes it easy to install on walls, tripods, production lines, or into tight spaces.
View Complete Details

E-beam Deposition Cones

At LTS, we manufacture superior E-beam deposition cones for thin film application. We supply these starter sources in metal, oxide, or fluoride formulations. Based on the customer request, we can manufacture insert liners in custom sizes as well as standard sizes such as 13 cc, 15 cc, 20 cc, 25 cc, and 40 cc to fit your needs.
View Complete Details

Precious Metals

LTS produces an array of precious metal alloys containing platinum, silver, ruthenium, gold, palladium, etc., prized in industry as coatings for their high chemical resistance, electrical conductivity, and catalytic potential. Using e-beam melting, we can make very small packages of 1 gram to 25 grams or larger pieces. Call us for a quote. .Product list of precious metal alloys:View the standalone brochure.GOLD ALLOYSGold BoronGold GermaniumGold PalladiumGold TinZinc Oxide GoldSILVER ALLOYSGraphite SilverMagnesium SilverSilicon Dioxide SilverSilver AluminumSilver BismuthSilver Calcium
View Complete Details

TLS Wavelength Tunable Monochromatic Light Source

TLS wavelength tunable monochromatic light source including LSH series deuterium lamps, tungsten halogen lamp or xenon lamps light source housing, with Omni-series monochromators (Omni-150 or Omni-300), with the filter wheel and other peripheral accessories .
View Complete Details

TLSE Enhanced Wavelength Tunable Monochromatic Light Source

TLSE Enhanced wavelength tunable monochromatic light source is updated from TLS further optical and alignment optimization, optimize the gratings, mirrors, light source power supply, bulb and so on, make the TLSE light source output optical power optimization, and more important is we can guarantee the consistency of the output light intensity for each unit. Currently we are providing TLSE including 1. TLSE1805i-X150 (UV-NIR, 200-2000 nm) 2. TLSE1805i-EQ (UV-NIR, 200-2000 nm) 3. TLSE1815i-SiN40 (IR, 1-14m) 4. TLSE1805i-X150 (UV-NIR, 200-1500 nm)
View Complete Details

Optical Lens Spectral Transmittance Detection System

Features The transmittance of this system is >10%Lens aperture: 8150mm(Through an aperture change selection), the max wavelength 600mmTriple grating-monochromator(300mm focal length), automaticalscan and grating switch freely.Spectral Range: 3802500nmMotized stage, Adjusting the optical system deterinated to the appropriate location along the optical axisTungsten light source with chopper and High stable constant-current power supply the accuracy of transmittance: 2%Spectroscopy software and filter wheel software, Output data collection and analysis and calculation software, measurement parameters are automatically saved and can be printed directly
View Complete Details

High Precision Microscope Stage

We are offering following High precision XYz stage 1. Piezo Z-stage for Microscopes 2. Motorized Stages for Inverted Microscopes 3. Microscopes Motorized Stages for Upright Microscopes 1. Piezo Z-stage for Microscopes The BioPrecision2 Piezo focus insert features all of the expected performance of a Piezo focus but adds improved compatibility with standard stage accessories including multi-well plateholders, slideholders, perfusion chamber sandincubators. There are two versions of the LEP PiezoZ-stage.The 96A602 PiezoZ-stage has alarger aperture and accommodates industry standard specimenholders.The larger insert allows theuse of many popular accessories for live cell research.The larger format also makes specimen exchange easier with less chance of up setting sensitive samples.The 96A603 PiezoZ-stage is more compactand is compatible with standard LEP inverted stages that featurea standard("FrameK") opening.
View Complete Details

Waveplates

Waveplates and retardation plates are opticalelements with two principalaxes, one slow and one fast, which resolve an incident polarized beam Into two mutually perpendicular polarized beams.Theiroperation is based on birefringent linear effect, which is the difference in the refractive indices for the beams with paralleland normal polarization towards the opticalaxis of the crystalline quartz materialbeing withinthe waveplate plane.The emerging beam recombines to form a particular single polarized beam. 1. Zero Order Waveplate(Optically Contacted, Air-Spaced, Cemented)2. Multiple Order Waveplate3. DualWavelengthWaveplate4. Achromatic Waveplate5. Polarization Rotator
View Complete Details

Crystal

We are offering following Crystals 1. Laser Crystalsa) Nd-YVO4 Crystalb) Nd-GdVO4 Crystal c) Ti-Sapphire Crystal d) Yb-YAG Crystale) Nd-YAG Crystal (Rod) 2. Passive crystalsa) Cr4+:YAG Crystal 3. AO and EO Crystala) Fe_LiNbO3 Crystal b) LiNbO3 SAW Crystal 4. Birefringent Crystala) Calcite Crystalb) YVO4 Crystal c) Alpha-BBO Crystal 5. Optical Crystala) Sapphire Crystalb) YAG Crystal Laser Crystals a) Nd-YVO4 Crystal Nd:YVO4 is one of the most efficient laser host crystal currently existing for diode laser-pumped solid-state lasers. Its large stimulated emission cross-section at lasing wavelength, high absorption coefficient and wide absorption bandwidth at pump wavelength, high laser induced damage threshold as well as good physical, optical and mechanical properties make Nd:YV04 an excellent crystal for high power, stable and cost-effective diode pumped solid-state lasers
View Complete Details

Solar Cell Quantum Efficiency (QE)

  • Functions Spectral responsively, Internal quantum efficiency, External quantum efficiency, Reflectivity, Transmissivity, Short circuit current density, QE-mapping and Reflectivity-mapping.
The Solar Cell Scan 100 series is a multifunctional experimental platform, which is based on the measurement of Quantum Efficiency (QE). The system employs a turnkey integrated design, which can carry out QE, Reflectivity and Mapping testing functions automatically. There are also modular and custom designed accessories to adapt to different solar cell samples.
View Complete Details

Carborundum Infrared Light Source

Carborundum Infrared Light Source is combinated light housing LSH-SiN40 and power supplyLSP-T200.It has high Luminous efficiency, small Luminous area, collect easily;do not need water cooling and it is very convenient for application , the life time is 2000hours.
View Complete Details

Spectro-Radiometer For Light Source Characterisation

The ZLX-ES series spectro-radiometer systems are designed for the accurate measurement of the radiant power emitted from a light source as a function of wavelength. Typical examples include the measurement of LEDs, tungsten and fluorescent lamps. The system is highly modular and can be configured using either short or long focal length monochromators, such as the Omni-300 or Omni-750 respectively, depending upon the spectral resolution required. Depending upon the measurement requirements two system configurations are commonly used. For high speed characterisation of light sources in the UV to Visible range a CCD array detector can be use with the Omni- series used in spectrograph mode. This mode is, for example, particularly useful for the characterisation of LED sources. A remote head collection head option is available for UV to VIS sources and is coupled to the analysing monochromator spectrograph using an optical fibre. In the UV to IR spectral ranges a variety of calibrated detectors can also be used with the monochromator in scanning mode.
View Complete Details

Lenses

A lens is an optical device with perfect or approximate axial-symmetry which transmits and refracts light, concentrating or diverging the beam.A simple lens is a lens consisting of a single opticalelement.A compound lens is an array of simple lenses (elements) with a common axis;the use of multiple elements allows more opticalaberrations to be corrected than is possible with a single element. We offer following lenses A. BK7 Simple LensesB. Fused Silica Simple LensesC. Meniscus LensesD. Doublet LensesE. Cylindrical Lenses
View Complete Details

Photocatalysis Special Light Source

LSXS-500 Photocatalysis special light source has 500W Xe Lamp, it will form arc discharge understand High frequency high voltage excitation; Spherical pressure short arc xenon lamp is a small point source with emitting point when ignited radiate strong and stable; From UV to NIR has strong continuous spectrum, VIS is very close to the visible light color daylight, High energy density, stable output; Application: Photolysis of water into hydrogen, photodegradation of pollutants, various types of simulated sunlight visible acceleration experiments, various simulated sunlight ultraviolet accelerated test and other research fields.
View Complete Details

Scattered Light Meter

Scattered light test site The Optiv has a low-vibration granite construction, and features motorized zoom optics to allow a wide range of demanding 3D measuring tasks. Measurement accuracy: Laser wave length: 632.8 nmMeasurement plane measuring surface: 0.8mm x 0.8mmMeasuring angle adjustable: 30 - 60
View Complete Details

High-Speed Motion Capture System

  • Features Up to 5 hours of continuous recording 5-1000 fps high resolution cameras 5-1000 fps high resolution cameras 2-D and 3-D video-based motion analysis Etc
The High-Speed Motion Capture System developed by Xcitex, is MiDAS and award winning ProAnalyst software for video engineering, introduces a new low-cost, high-performance motion capture system designed to record live video and data synchronously. The ProCapture motion capture system is ideal for researchers and engineers who study motion in a variety of industries such as aerospace, applied science, automotive, ballistics, biomechanics and sports, research and development, life sciences, process control and engineering. The foundation of the ProCapture system is the 1000 fps Xcitex high resolution camera controlled by the feature-rich ProCapturesoftware. In addition, ProAnalyst motion analysis software is included with each ProCapture system so that motion can becaptured, downloaded and analyzed in minutes. The ProCapture system can be configured with as many as eight Xcitex high-speed cameras and up to 32 channels of datacollection for either 2-D or 3-D motion capture and analysis. Video and data sources are automatically synchronized, ensuringa multi-perspective capture of every significant event.
View Complete Details

Intense Pulsed Light (IPL)Products

IPL Filter IPL filter is the key optical element for IPL (Intense Pulsed Light) machine, which filters the UV wave and reserve the useful wave from 400nm to 1200nm for cosmetic laser, such as photrevujenation, hair removal, vascular and acne treatment. The IPL Filters include IPL Internal Filters and IPL External Filters.
View Complete Details

UV-VIS Spectrophotometer Standard Device

Characteristics of UV-VIS spectrophotometer 1. This system is single-beam and Sample is placed vertically on the parallel beam, then measure transmittance; Including four pats: double-monochromator, light housing, sample chamber, motion control and software.2. Accurate measurement of spectral transmittance3. Double-monochromator , focal length 750mm scan automatically4. Large dimension grating110mm110mm, high energy efficiency.5. Photometric measurement accuracy, Uncertainty of Measurement is larger than 0.05%T6. High wavelength accuracy 0.05nm, high repeatability is 0.005nm7. Improving imaging quality by toroidal mirrors.8. Sample stage holding the sample can be automatically shifted out of the optical path
View Complete Details

Software For Adaptive Optics

ALPAO Core Engine (ACE) is powerful software architecture for adaptive optics.Using ACE, you are able to develop quickly and efficiently your own adaptive optics instruments. Features 1.Easeofuse ACE user friendly graphical interface allows fine tuning and to close the loop inone click. ACE is also easy to learn because of its convenient built-indocumentation, which includes realistic examples.With ACE, you can easily optimize your AOsystem to your needs. Automatedexperiments and advanced control setupsare easy to develop. It is also possible toimplement use of adaptive optics withoutwavefront sensors and to correct for quasistatic optical aberrations. 1. User friendly graphical interface 2. Customize your AO system to your needs
View Complete Details

Thickness Measurement Products

  • Applications Amorphous & Polysilicon CMP Dielectrics Glass & Plastic Thickness Hardcoat Thickness IC Failure Analysis ITO & Other TCOs Medical Devices Etc
Devices can measure range of thicknesses from 1 nm to 13 mm (varies with material type). Furthermore, these devices can measure up to three individual films in a stack. In some circumstances these devices can also measure dozens of layers. Thickness can be measured by measuring single-spot measurements, microscopic-spot measurements, automated mapping system and inline monitoring.
View Complete Details

Motion Analysis Software

ProAnalyst is the world's premier software package for automatically measuring moving objects with video. ProAnalyst allows you to import virtually any video and quickly extract and quantify motion within that video. Used extensively by NASA, engineers, broadcasters, researchers and athletes, ProAnalyst is the ideal companion software to any prosumer, scientific and industrial video camera, and vice versa. With ProAnalyst, any video camera becomes a non-contact test instrument.
View Complete Details

Prisms

We are offering following Prisms 1. Penta Prisms2. Right Angle Prisms3. Corner Cube Retroreflector prism4. Dispersive Anamorphic Prisms5. Wedges 1. Penta Prisms Penta Prism is a five-sided prism containing two reflecting surfaces at 45 to each other, and two refracting faces perpendicular to the entering and emerging beams. The deviation angle of 90deg is thus independent of the orientation of the prism, making it especially important in applications in which the prism orientation cannot be precisely controlled. Due to the geometry that total internal reflection cannot be used, the reflecting surfaces must be coated with a metallic or dielectric coating. The standard Penta Prism reflecting surfaces are coated with aluminum or enhanced aluminum. The coated surfaces can be painted black. The penta prism is a five-sided prism. It reflects light rays through a 90 angle by two reflections and does invert or revert the image. The reflecting surfaces are aluminized. Slight movement of the prism does not affect the true right angle at which light rays are reflected. It also shortens the optical path length of an instrument
View Complete Details

Polarizers

A polarizer is an important optical component that is widely used in optics to produce a state of linear polarization. Crylight supply a wide range of polarizers, including Glan Laser, Glan Taylor, Glan Thompson, Wollaston and Rochon by employing birefringent crystals: a-BBO, Calcite, YV04 and quartz. The material properties of birefringent crystals are deciding factors in your selection of the right type polarizer. We are providing following type of polarizers 1. Glan Taylor Polarizer2. Glan Laser Polarizer3. Glan Thompson Polarizer4. Wollaston Polarizer5. Rochon Polarizer
View Complete Details

Inferferometer

Interferometer with phase shift and integrated 640px x 480px digital camera Laser wavelength: 632.8 nmPV repeatability: 300RMS-repeatability: 10000Resolution: 8000Beam width vertical: 150 mmBeam width plane horizontal: 100 mmMeasurement range radius measurement: 1000 mm
View Complete Details

Optical Amplifier

  • Features Wavelengtd 630nm – 1064nm Output power up to 2W Nearly diffraction limited Easy coupling to master oscillator
  • Benefits High performance, low cost Stable and robust Use witd MOGLabs External Cavity Diode Las
  • Applications Laser cooling and trapping Bose-Einstein condensation Quantum optics: squeezed light Etc
The MOGLabs Optical Amplifier is an indispensable extension for single-frequency external cavity diode lasers. Laser power is increased by up to 2W, while maintaining tde tunability and linewidtd of tde injection seed laser.Replacement of tde amplifier diode and alignment are easily accomplished by tde end- user. Input and output Faraday isolators are a recommended optional addition. Wavelengtd options extend from 630nm to 1064nm, and power from 500mW to 2W.
View Complete Details

Centering Gauge

Measurement accuracy: Measurement range: 1m - 5mMeasuring unvertanty: max. 0.05mmMeasuring uncertanty (multiple measurement): max. 0.03mmMeasuring application reflectionMaximum test probe width: 25mm
View Complete Details

Autocollimator

Nikon 6D: Autocollimator for measurement of very small angular errors Telescope's magnification: 38xObjective f=700mm; effective aperture: 70mmMeasuring range: 30 arcminMeasuring unvertainty: 0.5" arcsec within an area of 5 arcmin1 arcsec within an area of 30 arcminLight source: LED
View Complete Details

Tungsten-halogen Light Sources

Currently we are providing following tungsten-halogen light sources 1. 50W Tungsten-halogen Light SourceLSTS-50 2. 50W Tungsten-halogen Light SourceLSB-T50AUV 3. 75W Tungsten-halogen Light SourceLSTS-75) 4. 75W Tungsten-halogen Light Source LSB-T75 5. 150W Tungsten-halogen Light SourceLSTS-150 6. 150W Tungsten-halogen Light SourceLSB-T150 200-400 high power Tungsten-halogen Light Source 7. 200W Tungsten-halogen Light SourceLSTS -200 8. 200W Tungsten-halogen Light Source LSTS -200 9. 250W Tungsten-halogen Light Source LSTS -250 10. 350W Tungsten-halogen Light Source LSTS -350
View Complete Details

3D Measurement System

The new Optiv Performance 443 is capable of both contact-less and tactile measurement procedures. Tactile scanning, touch-trigger probes, vision sensors, chromatic white light and through-the-lens lasers. The Optiv has a low-vibration granite construction, and features motorized zoom optics to allow a wide range of demanding 3D measuring tasks. Measurement accuracy: X: 1.9 + 4L1000 (m)Y: 1.9 + 4L1000 (m)Z: 1.9 + 5L1000 (m)
View Complete Details

300W Photochemical Catalysis

  • Features High collimation, high energy output High stability, unstability degree<1° The function of turning off light within certain time High effective air-cooling and long bulb lifetime Accessories: right bracket, filter, fiber holder and so on.
Photocatalysis, industrial catalysis, hydrogen aquatic photolysis, photochemical catalysis, photochemistry synthesis, optical degradation of pollutants, water pollution treatment, biological light, optical detection, various accelerated test simulated sunlight visible, ultraviolet band accelerated test and other research areas
View Complete Details