Our Products
Specifications
Charge | Afff (6%) - 540 ml |
---|---|
Capacity | 9 litre |
Propellant | 120 grams Co2 Stored in Gas cartridge |
Rating | 2 A 21B |
Minimum Effective discharge time | 13 Seconds (Minimum) |
Bulk Range discharge | 2 meter (minimum) |
Cylinder testing pressure | 35 bar |
Service pressure | 12 bar max. |
Working temperature | - 30oC to + 55oC |
Weight of one charged extringuisher | 17 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | A and B class fire |
Specifications
Charge | Water |
---|---|
Capacity | 9 litre |
Propellant | 90 grams Co22 Stored in Gas cartridge |
Rating | 2A |
Minimum Effective discharge time | 13 Seconds (Minimum) |
Bulk Range discharge | 2 meter (minimum) |
Cylinder testing pressure | 35 bar |
Service pressure | 12 Bar max. |
Working Temperature | +5oC to + 55oC |
Weight of one charged extinguisher | 17 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | A class fire |
Specifications
Charge | Co2 Gas |
---|---|
Capacity | 4.5 kg |
Rating | 21 B |
Minimum Effective Discharge time | 8 Seconds (Minimum) |
Bulk Range discharge | 2 meter (mimimum) |
Cylinder Testing pressure | 250 bar |
Gas storage pressure | 50 kg / cm2 approx. |
Filling density | 0.667 max. |
Working Temperature | - 30oC to + 55oC |
Weight of one charged extinguisher | 17 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | B and C class fire |
Specifications
Charge | Co2 Gas |
---|---|
Capacity | 3 kg |
Rating | 13B |
Minimum effective discharge time | 8 Seconds (minimum) |
Bulk Range discharge | 1 meter (minimum) |
Cylinder testing pressure | 250 bar |
Gas storage pressure | 50 kg/cm2 approx. |
Filling density | 0.667 Max. |
Working temperature | - 30oC to + 55oC |
Weight of one charged extinguisher | 12.5 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | B and c Class fire |
Specifications
Charge | Abc dry powder (Map 50 / Map 90) |
---|---|
Capacity | 4 kg |
Propellant | Dry nitrogen to 15 kg / cm2 |
Rating | 2 A 21B |
Minimum Effective discharge time | 13 seconds (minimum) |
Bulk range Discharge | 2 Meter (Minimum) |
Cylinder testing pressure | 35 bar |
Service pressure | 15 bar |
Working temperature | -30oC to + 55 oC |
Weight of one charged extinguisher | 7 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | A, B and C class fire |
Specifications
Charge | Co 2Gas |
---|---|
Capacity | 2 kg |
Rating | 8 B |
Minimum Effective discharge time | 8 seconds (Minimum) |
Bulk Range Discharge | 1 meter (minimum) |
Cylinder testing pressure | 250 bar |
Gas storage pressure | 50 kg/cm2approx. |
Filling density | 0.667 Max. |
Working Temperature | - 30oC to + 55oC |
Weight of one charged extinguisher | 9 kg (approx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | B and C class fire |
Specifications
Charge | Halotron tm I |
---|---|
Capacity | 10 kg |
Propellant | Dry argon to 15 kg / cm2 |
Temperature Rating | 57oC / 68oC / 79oC |
Area coverage | 9 Sq. Meter (approx.) |
Cylinder Testing pressure | 30 bar |
Service pressure | 15 bar |
Weight of one charged extinguisher | 16 kg (approx.) |
Suitable for | A, B and C class fire |
Specifications
Charge | Dry chemical powder (sodium Bi-carbonate) as per IS 4308 |
---|---|
Capacity | 6 kg |
Propellant | 120 grams Co2 stored in Gas cartridge |
Rating | 21B |
Minimum Effective discharge time | 8 seconds (minimum) |
Bulk Range Discharge | 2 meter (minimum) |
Cylinder testing pressure | 35 bar |
Service pressure | 12 bar max. |
Working temperatue | - 30oC to + 55oC |
Weight of one charged extinguisher | 11.5 kg (apporx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | B and C class fire |
Specifications
Charge | ABC Dry powder (MAP50 / MAP 90) |
---|---|
Cpacity | 5 kg |
Propellant | Dry Nitrogen to 15 kg/cm2 |
Temperature Rating | 57oC / 68oC / 79oC |
Area coverage | 9 Sq. Meter (approx.) |
Cylinder testing pressure | 30 bar |
Service pressure | 14 bar |
Weight of one charged extinguisher | 9.55 kg (approx.) |
Suitable for | A, B and C class fire |
Specifications
Charge | Halotron tm I |
---|---|
Capacity | 2 kg |
Propellant | Dry Argon to 15 kg/cm2 |
Rating | 1A 8B |
Minimum Effective Discharge time | 8 Seconds (minimum) |
Bulk Range Discharge | 2 meter (Minimum) |
Cylinder Testing Pressure | 35 Bar |
Service pressure | 15 bar |
Working Temperature | - 30oC to + 55oC |
Weight of one charged extinguisher | 4.2 kg (apporx.) |
Standard specification | IS 15683 : 2006 |
Suitable for | A, B and C class fire |
Specifications
Charge | Halotron Tm 1 |
---|---|
Capacity | 1 kg |
Propellant | Dry argon to 15 kg/cm2 |
Rating | N.A. |
Minimum Effective discharge time | 8 Seconds (Minimum) |
Bulk Range Discharge | 2 meter (minimum) |
Cylinder testing pressure | 35 bar |
Service Pressure | 15 bar |
Working temperature | - 30oC to + 55oC |
Weight of one charged extinguisher | 2.8 kg (approx.) |
Standard Specification | IS 15683 : 2006 |
Suitable for | A, B and C Class fire |
Specifications
Charge | Abc dry powder (Map50 / Map90) |
---|---|
Capacity | 1 kg |
Propellant | Dry Nitroen to 15 kg/cm2 |
Rating | N.A. |
Minimum Effective discharge time | 8 seconds (Minimum) |
Bulk Range discharge | 2 Meter (Minimum) |
Cylinder Testing Pressure | 2 meter (Minimum) |
Cylinder Testing pressure | 35 bar |
Service pressure | 15 bar |
Working Temperature | - 30oC to + 55 oC |
Weight of one charged extinguisher | 2.8 kg (approx.) |
Standard specification | IS 15683 (applied for) |
Suitable for | A, B and C class fire |