Our Products
We offer a complete product range of Mechanical Foam Fire Extinguisher, Water Fire Extinguisher, CO2 Fire Extinguisher- (4.5kg), CO2 Fire Extinguisher (3kg) and ABC Dry Powder Fire Extinguisher (4kg)
Specifications
| Charge | Afff (6%) - 540 ml |
|---|---|
| Capacity | 9 litre |
| Propellant | 120 grams Co2 Stored in Gas cartridge |
| Rating | 2 A 21B |
| Minimum Effective discharge time | 13 Seconds (Minimum) |
| Bulk Range discharge | 2 meter (minimum) |
| Cylinder testing pressure | 35 bar |
| Service pressure | 12 bar max. |
| Working temperature | - 30oC to + 55oC |
| Weight of one charged extringuisher | 17 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | A and B class fire |
Specifications
| Charge | Water |
|---|---|
| Capacity | 9 litre |
| Propellant | 90 grams Co22 Stored in Gas cartridge |
| Rating | 2A |
| Minimum Effective discharge time | 13 Seconds (Minimum) |
| Bulk Range discharge | 2 meter (minimum) |
| Cylinder testing pressure | 35 bar |
| Service pressure | 12 Bar max. |
| Working Temperature | +5oC to + 55oC |
| Weight of one charged extinguisher | 17 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | A class fire |
Specifications
| Charge | Co2 Gas |
|---|---|
| Capacity | 4.5 kg |
| Rating | 21 B |
| Minimum Effective Discharge time | 8 Seconds (Minimum) |
| Bulk Range discharge | 2 meter (mimimum) |
| Cylinder Testing pressure | 250 bar |
| Gas storage pressure | 50 kg / cm2 approx. |
| Filling density | 0.667 max. |
| Working Temperature | - 30oC to + 55oC |
| Weight of one charged extinguisher | 17 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | B and C class fire |
Specifications
| Charge | Co2 Gas |
|---|---|
| Capacity | 3 kg |
| Rating | 13B |
| Minimum effective discharge time | 8 Seconds (minimum) |
| Bulk Range discharge | 1 meter (minimum) |
| Cylinder testing pressure | 250 bar |
| Gas storage pressure | 50 kg/cm2 approx. |
| Filling density | 0.667 Max. |
| Working temperature | - 30oC to + 55oC |
| Weight of one charged extinguisher | 12.5 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | B and c Class fire |
Specifications
| Charge | Abc dry powder (Map 50 / Map 90) |
|---|---|
| Capacity | 4 kg |
| Propellant | Dry nitrogen to 15 kg / cm2 |
| Rating | 2 A 21B |
| Minimum Effective discharge time | 13 seconds (minimum) |
| Bulk range Discharge | 2 Meter (Minimum) |
| Cylinder testing pressure | 35 bar |
| Service pressure | 15 bar |
| Working temperature | -30oC to + 55 oC |
| Weight of one charged extinguisher | 7 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | A, B and C class fire |
Specifications
| Charge | Co 2Gas |
|---|---|
| Capacity | 2 kg |
| Rating | 8 B |
| Minimum Effective discharge time | 8 seconds (Minimum) |
| Bulk Range Discharge | 1 meter (minimum) |
| Cylinder testing pressure | 250 bar |
| Gas storage pressure | 50 kg/cm2approx. |
| Filling density | 0.667 Max. |
| Working Temperature | - 30oC to + 55oC |
| Weight of one charged extinguisher | 9 kg (approx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | B and C class fire |
Specifications
| Charge | Halotron tm I |
|---|---|
| Capacity | 10 kg |
| Propellant | Dry argon to 15 kg / cm2 |
| Temperature Rating | 57oC / 68oC / 79oC |
| Area coverage | 9 Sq. Meter (approx.) |
| Cylinder Testing pressure | 30 bar |
| Service pressure | 15 bar |
| Weight of one charged extinguisher | 16 kg (approx.) |
| Suitable for | A, B and C class fire |
Specifications
| Charge | Dry chemical powder (sodium Bi-carbonate) as per IS 4308 |
|---|---|
| Capacity | 6 kg |
| Propellant | 120 grams Co2 stored in Gas cartridge |
| Rating | 21B |
| Minimum Effective discharge time | 8 seconds (minimum) |
| Bulk Range Discharge | 2 meter (minimum) |
| Cylinder testing pressure | 35 bar |
| Service pressure | 12 bar max. |
| Working temperatue | - 30oC to + 55oC |
| Weight of one charged extinguisher | 11.5 kg (apporx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | B and C class fire |
Specifications
| Charge | ABC Dry powder (MAP50 / MAP 90) |
|---|---|
| Cpacity | 5 kg |
| Propellant | Dry Nitrogen to 15 kg/cm2 |
| Temperature Rating | 57oC / 68oC / 79oC |
| Area coverage | 9 Sq. Meter (approx.) |
| Cylinder testing pressure | 30 bar |
| Service pressure | 14 bar |
| Weight of one charged extinguisher | 9.55 kg (approx.) |
| Suitable for | A, B and C class fire |
Specifications
| Charge | Halotron Tm 1 |
|---|---|
| Capacity | 1 kg |
| Propellant | Dry argon to 15 kg/cm2 |
| Rating | N.A. |
| Minimum Effective discharge time | 8 Seconds (Minimum) |
| Bulk Range Discharge | 2 meter (minimum) |
| Cylinder testing pressure | 35 bar |
| Service Pressure | 15 bar |
| Working temperature | - 30oC to + 55oC |
| Weight of one charged extinguisher | 2.8 kg (approx.) |
| Standard Specification | IS 15683 : 2006 |
| Suitable for | A, B and C Class fire |
Specifications
| Charge | Halotron tm I |
|---|---|
| Capacity | 2 kg |
| Propellant | Dry Argon to 15 kg/cm2 |
| Rating | 1A 8B |
| Minimum Effective Discharge time | 8 Seconds (minimum) |
| Bulk Range Discharge | 2 meter (Minimum) |
| Cylinder Testing Pressure | 35 Bar |
| Service pressure | 15 bar |
| Working Temperature | - 30oC to + 55oC |
| Weight of one charged extinguisher | 4.2 kg (apporx.) |
| Standard specification | IS 15683 : 2006 |
| Suitable for | A, B and C class fire |
Specifications
| Charge | Abc dry powder (Map50 / Map90) |
|---|---|
| Capacity | 1 kg |
| Propellant | Dry Nitroen to 15 kg/cm2 |
| Rating | N.A. |
| Minimum Effective discharge time | 8 seconds (Minimum) |
| Bulk Range discharge | 2 Meter (Minimum) |
| Cylinder Testing Pressure | 2 meter (Minimum) |
| Cylinder Testing pressure | 35 bar |
| Service pressure | 15 bar |
| Working Temperature | - 30oC to + 55 oC |
| Weight of one charged extinguisher | 2.8 kg (approx.) |
| Standard specification | IS 15683 (applied for) |
| Suitable for | A, B and C class fire |