Our Products
Testing Equipments
2 Products availableLaboratory Equipments
2 Products availableMeasuring Instruments & Equipment
1 Products availableFood Processing Machines & Plants
1 Products availableDehumidifiers
1 Products availableChillers
1 Products availableWe are leaders in the market for providing best range of Viscometric Bath, Vertical Cold Chamber and Terg-O-Tometer
Above Ambient To 99.9Degree C / 0 C To 99.9DegreeC/ -10 C To 99.9DegreeC
+ 0.1DegreeC TO 0.5DegreeC
This equipment is specially designed for tests in the field of Medical / Agricultural / Bio-chemical / R & D & Q.C Laboratories & also suits various IS & A S T M Standards.
Double walled, Exterior of CRCA / GI Non-contaminant Epoxy Powder coated & Inner chamber of AISI S.S 304, with PUF insulation, S.S Lid on top with provision for holding Viscometer Holders.
Efficient Motor of 1440 RPM Top Mounted is installed for stirring to get temp. uniformity.
S. S Tubular Heaters for maintaining of temp.
Hermitically Sealed compressor provides temp. for below ambient conditions. Refrigerant CFC Free.
Solid state electronic Digital Temp. Control panels housing all the control switches with PT-100 Sensor.
Models available as per GMP / Complete S.S unit, Strip Chart Recorder. Microprocessor based PID temp. Control with printer interface, RS 232 CPC / RS -485 interface for multing networking of controller. (Data Logger).
Validation Protocols for IQ, OQ, PQ, DQ complete documentation with reports, Calibration & Test Certificates.
Safety thermostats for over shooting of temp. safety circuit to cut off the whole system in case of malfunction (Applicable to microprocessor based models only) HRC fuses for compressor heaters & mains, time delay circuit for safety of compressor.
This chamber product is frequently used for research application such as lighting for plant pathology research and seedling germination and development.
Three tiers of lighted shelving is lit by LED fluorescent white lights & tungsten incandescent lamps properly spaced for uniform light intensity. Intensity is adjustable from 600 to 2000 moles/m2/s at 150mm distance from the lamps. Programming and control of the lighting is done controller between temperature +10degree C to +40degree C. Lamps with 3 on/off light events.Par sensor for light measurements.
Interior Made of 22 guage plated steel exterior of 18 guage plated steel construction 51mm thick puff panels with puff in place dencity of minimum 1 kg per cubic foot or its equivalent. Insulation with expanded polystyrene or any equivalent.material having R factor of minimum 34 shall maintain its dimensional stability in an operating temperature range of +4C to +50C.Insulation panel or its equivalent shall have cam-type fasteners with vinyl gasket or its equivalent. Environment friendly foam (Global warming potential of 0.0 & ozone depletion potential of 0.0 )
PLC based PID controller with5.6 LCD is capable of controlling temperature, humidity, CO2 and lighting. Programs may be configured to run in real time or countdown (circadian) mode. Ramping and nonramping program methods are available for eachprogramming mode. Multiple programs are linked to create complex environmental profiles. additional informationSEED GERMINATOR SR regarding the control system 25 steps PLC with HMI based temp. & RH controller, with 50 real time use entered programs in with 99 cycles in each programs. provides precise temp., RH, Humidity, illumination & CO2 maintaining uniform & accurate growth environment. Timer, alarm, auto tuning & auto start, stop function. with printer interface (centronic port). PC interface with RS232CPS / RS-485 interface for multiple networking of controller. Data loggers up profile controller for Ramp / soak for cyclic applicationchamber illumination of U.V. Lamps. Low water level circuit etc. Also available stand by humidity & refrigeration system (Manual & auto change over) as optional. Auto diagnostic feature. Ambient temp. monitoring. Autorestart in case of power failure. 24 hour chamber monitoring 4 level password protection for controller operation.
+10 degree C to +60degree C with lights ON
0degree C to +60degree C with lights OFF
4 Epoxy coated steel shells painted in white shelves will be adjustable in 0.5 inch increment.
50% to 90% RH, + 3% Through ultrasonic humidification with high/Lowalarm. Extended humidity ranges available. It is PAN type humidifierwith RH sensor of rotronic hygroclip of SWISS make.
Air cooled condensing unit which is self contained with hot gas bypass system for continues compressor operation. Temperature control in accurate and it extends its life by alternately cycling refrigerant and hot gas to the coil. Long neck solenoid values for quiet and long life operation.
(Experiment Protection) Adjustable high and low temp. controls, audible alarms, and visual in directors are provided.the controls shut down all the power to the chamber, and activates alarms. when the temperature returns to the normal range the system will auto-matically reset.
Two reach in doors for full access. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self closing cam lift gravity hinges or its equivalent a posi-seal door closure or its equivalent. Door shall have key lockable latch handle with an inside safety release. Magnetic gasket is provided for a tight seal.
40% to 95% RH, + 3% Through ultrasonic humidification with high/Low alarm. Extended humidity ranges available. It is PAN type humidifier with RH sensor of rotronic hygroclip of SWISS make.
Built-in temp. deviation, audio/visual alarms. Safety thermostat for over shooting of temp. safety circuit to cut of the whole systems in case of malfunction. (only applicable to microprocessor based models). HRS fuses for compressor heaters & mains.
Uniform forced air circulate across the shelf via air diffusers on the top wall.
0-2000 ppm complete with cylinders & regulators operateddirectly from PLC with NDIR sensors.
These Ice Flakers are the most suitable Ice Flake machines used in laboratories worldwide. With use of international quality standard material and advanced manufacturing and designing technology, our units prove to be highly reliable and durable flake ice makers available on the market today. These system are supplied to all over India and exported t Asian, African, & Middl East countries with Economical price and excellent warranty.
S. S bin of 304 quality for collection of Ice & the outer is made of CRCA non-contiminant expoxy powder coated, it rests on heavy angular frame structure. These units are fully automatic S.S. bin of 304 quality for collection of ICE & the outer is also of stainless steel 304 grade, it reset on heavy angular frame structure and hygienic sealed water system make this ice machine perfect for installation in factory Environments where people may be working around the machine.
FeaturesThese equipments are capable of maintaining Relative Humidity 35% RH to 45% RH & are mainly used in Pharmaceutical Laboratories Capsules, Strip packing, Tablet Section, Packing Rooms, Processing Industries, Printing & Lithography, Photographic Industries, Communication equipment rooms, Computer & data storage various other purposes
Heavy gauge construction of CRCA sheet or AISI Stainless steel, Robust angular structure removable casing panel makes all parts easily accessible for adjustments & service when required
These equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, materials for simulated tropical & extreme tropical conditions.
ConstructionThe chamber is triple wall at back & bottom inner both the walls are stainless steel 304 quality duly polished with mirror finish buffing & outer wall is Stainless Steel 304 quality mat finish. This Construction avoids rusting problems caused due to condensation at -700C humidity.
Heating & HumidificationAir Heaters are provided for heating above ambient temperatures.Ultrasonic humidification system for the chamber.
Air CirculationThe humidity chamber is provided with best air circulation to give better temperature uniformity this is achieved by using one set of motor & blower in baffle wall compartment to push treated air in working chamber. this system gives better than 1deg c. temperature uniformity in working chamber, evaporator, heaters & steam injection system is from back side, behind baffle wall, the air circulation blower is also fitted in this compartment only. This arrangement helps to mix steam and air together and pass well mixed air inside the working chamber. Due to above system the temperature and humidity (R.H.) in complete chamber almost uniform
These equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, materials for simulated tropical & extreme tropical conditions.
The chamber shall be of mono block structure construction, comprising three cabinet placed one above the other (Hot cabinet at top, ambient cabinet at middle and cold cabinet at bottom).
Exterior :The exterior housing must be made from lightweight, self-supporting, corrosion resistant, galvanized steel-sheet of suitable thickness. The outside surface of the exterior wall shall be primed and painted to a standard finish with high quality materials.
Interior :Complete construction of the inner test spaces shall be made of stainless steel AISI 304 or equivalent materials. All the joints shall be continuous seam welded to form a hermetically sealed unit in order to prevent external moisture migration.
The chamber shall have door at front side. The door shall be fully open able (180Degree C or more) to facilitate test article loading and unloading. Heaters shall be provided at the door at appropriate place to avoid moisture condensation on the outside surface. Suitable numbers of locks / clamps shall be provided to ensure the uniform pressure and air tightness of the chamber test space.
This unit is double walled chamber. Interior made of stainless steel and exterior iseither mild steel Finished with powder coating or stainless steel. Glass wool/pufinsulation between both the wall is Provided. Full-lenght inner glass door and outsidemetal door with magnetic gasket & lock. Forced air Circulation for uniform temperature.One stainless steel perforated tray is provided. The tray can be Placed at variousheights to accommodate the change in sample height. The purpose of doing so is toVary the exposure intensity to reduce the test duration. PU wheels for easy move ability.
Photo stability chambers provide lights as per option 2 mentioned inICH guidelines A cool white florescent light for 1, 2 million LUX hoursexposure. UV-A lights for 200 watt hours / square meter exposure.Both the lights have independent control to avoid over exposure.Chamber is illuminated using 4nos of flourescent tube light toproduce visible light (measure in lux). A one no. Near UV light ofwavelength 365nm ( measured in watt/sq. Meter) are fitted ontopside of the chamber.
Hermitically sealed compressor coupled with evaporation coiland condenser, safe guarded by time delay circuit. CFC freerefrigerant.
To comply with the documentation requirements, we provide IQ, OQ & PQ protocols to be executed before taking the chamber in to for regular use, and support the supply with the following documents with the detail operational and service manual.
Standard Operating Procedure (SOP) Operational Manual for Controller IQ, PQ, OQ protocols certificate. Calibration certificate of all controlling modules with traceability. Certificate of MOC. Test Report of chamber prior to supply with mapping certificate. wiring diagram for ease of service maintenance.
The equipment is PLC controlled and has controlled exposure withtemperature and humidity (optional). The light gets OFFautomatically once the exposure is achieved. Refrigeration and PIDcontrol heating systems are provided to carry out testing at aprecise Temperature. Humidity control system can also be provided.Temperature Controller with Ethernet Communication
Temperature Range: +20 C To +60 CAccuracy : 0.2 CTemperature Uniformity : 1c
Temperature Range: 40% To 85% RH.Accuracy : 1% RH.Uniformity : 3% RH.
Supervisory Safety Monitoring System has been introduced for additional Safety measures. Individual additional micro controlled is used for this supervisory system. If the temperature & humidity value crosses set Hi & Low limits for either or both parameters, safety control action will be taken over by this controller. If the parameters sets within the limit value, main control action will resume automatically. 2 Min. Compressor ON delay time for safety of compressor. Float switch to cutoff the main supply & audio visual alarms in case of low water level.
ICDAS Software : Centralized work station for viewing, trending performance of equipment. Software complies to US FDA21 CFR Part 11. Calibrated LUX and UV-A meters to measure visible light and UV light intensities Touch screen display. To satisfy regulatory requirements the equipment has Ethernet interface for communication with ICDAS software. It records temperature control, LUX exposure, UV exposure and optional Humidity control parameters .
21 CFR part 11 Compliance. Online & Offline Data representation in Tabular as well as Graphical Form. Separate display formats for Real time Data & Acquired Data for single or multiple chambers Mean Kinetic Value (MKT) as per USP 24 NP 19 Daily, Weekly, Monthly.
All stability chamber meet the ICH Q1A guidelines for stability testing including :
Long Term : 25 C/60% RH or 30C/60% RH
Intermediate : 30C/65% RH or 30C/75% RHAccelerated : 40C/75% RH.
ISO 9001:2015 Certified Co. D&B registered & CE mark product.Calibration & validation certificates traceable to NABL / ERTL accredited labs
This equipment is specially designed for tests in the field of Medical / Agricultural / Bio-chemical / R & D & Q.C Laboratories & also suits various IS & A S T M Standards.
Double walled, Exterior of CRCA / GI Non-contaminant Epoxy Powder coated & Inner chamber of AISI S.S 304, with PUF insulation, S.S Lid on top with provision for holding Viscometer Holders.
(Experiment Protection) Adjustable high and low temp. controls, audible alarms, and visual in directors are provided.the controls shut down all the power to the chamber, and activates alarms. when the temperature returns to the normal range the system will auto-matically reset.
Three tiers of lighted shelving is lit by LED fluorescent white lights & tungsten incandescent lamps properly spaced foruniform light intensity. Intensity is adjustable from 600 to 2000 moles/m2/s at 150mm distance from the lamps. Programming and control of the lighting is done controller between temperature +100C to +400C. Lamps with 3 on/off light events.Par sensor for light measurements.
Three tiers of lighted shelving is lit by LED fluorescent white lights & tungsten incandescent lamps properly spaced foruniform light intensity. Intensity is adjustable from 600 to 2000 moles/m2/s at 150mm distance from the lamps. Programming and control of the lighting is done controller between temperature +100C to +400C. Lamps with 3 on/off light events.Par sensor for light measurements.
+100C to +600C with lights ON
+00C to +600C with lights OFF
Uniform forced air circulate across the shelf via air diffusers on the top wall.
0-2000 ppm complete with cylinders & regulators operated directly from PLC with NDIR sensors.
Built-in temp. deviation, audio/visual alarms. Safety thermostat for over shooting of temp. safety circuit to cut of the wholesystems in case of malfunction. (only applicable to microprocessor based models). HRS fuses for compressor heaters & mains.
Air cooled condensing unit which is self contained with hot gas bypass system for continues compressor operation.Temperature control in accurate and it extends its life by alternately cycling refrigerant and hot gas to the coil. Longsolenoid values for quiet and long life operation.
PLC based PID controller with5.6 LCD is capable of controlling temperature, humidity, CO2and lighting. Programs may be configured to run in real time or countdown (circadian) mode. Ramping and nonramping program methods are available for each programming mode. Multiple programs are linked to create complex environmental profiles. additional informationregarding the control system 25 steps PLC with HMI based temp. & RH controller, with 50 real time use enteredprograms in with 99 cycles in each programs. provides precise temp., RH, Humidity, illumination & CO2 maintaining uniform & accurate growth environment. Timer, alarm, auto tuning & auto start, stop function. with printer interface(centronic port). PC interface with RS232CPS / RS-485 interface for multiple networking of controller. Data loggers up profile controller for Ramp / soak for cyclic application chamber illumination of U.V. Lamps. Low water level circuit etc. Also available stand by humidity & refrigeration system (Manual & auto change over) as optional. Auto diagnostic feature. Ambient temp. monitoring. Autorestart in case of power failure. 24 hour chamber monitoring 4 level password protection for controller operation.
Interior Made of 22 guage plated steel exterior of 18 guage plated steel construction 51mm thick puff panels with puff in place dencityof minimum 1 kg per cubic foot or its equivalent. Insulation with expanded polystyrene or any equivalent. material having R factor of minimum 34 shall maintain its dimensional stability in an operating temperature range of +40C to +500C.Insulation panel or its equivalent shall have cam-type fasteners with vinyl gasket or its equivalent. Environment friendly foam (Global warming potential of 0.0 & ozone depletion potential of 0.0 )
Two reach in doors for full access. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self closing cam liftgravity hinges or its equivalent a posi-seal door closure or its equivalent. Door shall have key lockable latch handle with an inside safety release. Magnetic gasket is provided for a tight seal.