1 Products availableRespirator
1 Products availablePower Purifiers
1 Products availableOur Complete range of products are SAFEON Power Purifier 10KW1P Lite, SAFEON Power Purifier 10KW3P Lite, SAFEON Power Purifier 15KW1P Lite, SAFEON Power Purifier 03KW1P Lite and SAFEON Power Purifier 05KW1P Lite.
Operating Voltage Range 180-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 3.6 KVA
Max. Operating Current 17 A (@180V)
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 180-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 6 KVA
Max. Operating Current 27 A (@180V)
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 180-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 12.5 KVA
Max. Operating Current 56 A (@180V)
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 180-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 12.5 KVA
Max. Operating Current 56 A (@180V)
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 200-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 11 KVA (3.6 KVA Per Phase)
Max. Operating Current 17 A (@180V) Per Phase
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V Per Phase
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 180-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 18 KVA
Max. Operating Current 80 A (@180V)
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 200-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 24 KVA (8 KVA Per Phase)
Max. Operating Current 40 A (@180V) Per Phase
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V Per Phase
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 200-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 30 KVA (10 KVA Per Phase)
Max. Operating Current 47 A (@180V) Per Phase
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V Per Phase
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15
Operating Voltage Range 200-260V AC Per Phase
Operating Frequency 48 Hz 62 Hz
KVA Rating (Max) 37.5 KVA (12.5 KVA Per Phase)
Max. Operating Current 56 A (@180V) Per Phase
Cooling Air (Natural/Forced)
Max. on State Voltage drop 2.5V Per Phase
Operating Ambient Temp. 5*C 50*C
Sensing Time 2 mS 4mS
Operating Frequency 10 mS
Max Signaling Time 20 mS
Max. Switching Time
Additional Information:
Delivery Time : 15