Technical details:thickness of layer : one single layer can achieve 1 mm dry coating thicknesse(approx. 0.91 kgm amount of coating )thickness of layer: wet dry 1, 5 mm wet 1, 0 mm dry 2, 2 mm wet 1, 6 mm dry 1, 5 mm wet 1, 0 mm dry 2, 2 mm wet 1, 6 mm dryshelf life (stored dry and free from frost): 12 monthsdensity uncured: approx. 1.30 gcmconsistency: can be applied by paint brush, roller or sprayedfull cure : 24 hrsapprovals:det norske veritas: iec 60332-3abs american bureau of shipbuilding: iec 60332-3german lloyd: iec 60331installation instructionopening clean the cables. The cables and cable supporting structuresmust be dry and free from dust , grease or oil, and installed incompliance with local building and electrical standards.Cp 678 is a ready-to-use product.Coverageon a flat surface coverage will be approximately 1.7 kgm (at 1mm dry film thickness)on cable bundles, and cable trays allow 2.0 to 3.5 kgm (at 1mm dry film thickness) depending on volume of cables, methodof application, and wastage (ie.overspray).Recommended tip size is 0.43 mm or 0.017 inch.Applicationcp 678 is applicable either by brush, roller or airless spray.1 mm dry coating thickness is required to meet dnv (detnorske veritas) orand abs (american bureau of shipping)certifications and germanischer lloyd din application.* note : one box contains 1 bucket of 20 kg. Rates specified are per kg.