Our product range contains a wide range of Continuously Variable (CV - CL) Power Supply - SVL, Continuously Variable Dual Output Power Supply, Precise Variable Power Supply, Fixed Output Power Supply and Rfi Filter

Continuously Variable (CV - CL) Power Supply - SVL

Features :-
Output Voltage Adjustable from 0 to Specified Voltage.
Current Limit Adjustable from 5% to 110% of Specified Load Current.
Load & Line Regulation: 0.05% max.
Ripple & Noise: 1 mV (r. m. S.) Max.
Protected Against Overload & Short Circuit by Means of Automatic Crossover Characteristics.
Continuous Metering of Output Voltage & Current.
Input Voltage: 230V AC 1 0%, 50Hz, Single Phase.
Operating Temperature Range: 0 to 550C.
Remote Sensing for Distantly Situated Loads for Models Above 5 Amps.
OPTIONAL FACILITIES : (At Extra Cost) :-
Over voltage Protection (Fixed / Variable).
Input Voltage: 115V AC 10%.
Rack-Mounting, Wall Mounting, Base Mounting.

TTL Compatible Active ON / OFF.

MODEL DESCRIPTION MODEL DESCRIPTION
SVL 015002 0 - 15V / 2A SVL 060001 0 - 60V / 1A
SVL 015004 0 - 15V / 4A SVL 060002 0 - 60V / 2A
SVL 015006 0 - 15V / 6A SVL 060003 0 - 60V / 3A
SVL 015008 0 - 15V / 8A SVL 060005 0 - 60V / 5A
SVL 015010 0 - 15V / 10A SVL 060010 0 - 60V / 10A
SVL 015020 0 - 15V / 20A SVL 060015 0 - 60V / 15A
SVL 015030 0 - 15V / 30A SVL 060020 0 - 60V / 20A
SVL 032001 0 - 32V / 1A SVL 060030 0 - 60V / 30A
SVL 032002 0 - 32V / 2A SVL 100001 0 - 100V / 1A
SVL 032003 0 - 32V / 3A SVL 100002 0 - 100V / 2A
SVL 032005 0 - 32V / 5A SVL 100003 0 - 100V / 3A
SVL 032010 0 - 32V / 10A SVL 100005 0 - 100V / 5A
SVL 032015 0 - 32V / 15A SVL 100010 0 - 100V / 10A
SVL 032020 0 - 32V / 20A SVL 100015 0 - 100V / 15A
SVL 032030 0 - 32V / 30A SVL 100020 0 - 100V / 20A
View Complete Details

Continuously Variable Dual Output Power Supply

  • MODEL DESCRIPTION
  • SVL 030001D 0 - 32V / 1 A Dual O/P
  • SVL 030002D 0 - 32V / 2A Dual O/P
  • SVL 030003D 0 - 32V / 3A Dual O/P
  • SVL 030005D 0 - 32V / 5A Dual O/P
  • SVL 030010D 0 - 32V / 10A Dual O/P
  • SVL 060001D 0- 60V / 1A Dual O/P
  • SVL 060002D 0 - 60V / 2A Dual O/P
  • SVL 060003D 0 - 60V / 3A Dual O/P
  • SVL 060005D 0 - 60V / 5A Dual O/P
  • SVL 060010D 0 - 60V / 1 OA Dual O/P
Features :-
Output Voltage Adjustable from 0 to Specified Voltage.
Current Limit Adjustable from 5% to 110% of Specified Load Current.
Two Completely Isolated Outputs can be configured in Series or Parallel to Enhance Voltage or Current Output Capacity Respectively.
Load & Line Regulation: 0.05% max.
Ripple & Noise: 1 mV (r. m. S.) Max.
Protected Against Overload & Short Circuit by Means of Automatic CrossoverCharacteristics.
Continuous Metering of Output Voltage & Current.
Input Voltage: 230V AC 10%, 50Hz, Single Phase
Operating Temperature Range: 0 to 550C.

Remote Sensing for Distantly Situated Loads for Models above 5 Amps.

OPTIONAL FACILITIES : (At Extra Cost) :-
Over voltage Protection (Fixed / Variable).
Input Voltage: 115V AC 10%.
Rack-Mounting, Wall Mounting, Base Mounting.
TTL Compatible Active ON / OFF.
View Complete Details

Precise Variable Power Supply

Features :-
Output Voltage Adjustable from 0 to Specified Voltage.
Current Limit Adjustable from 5% to 110% of Specified Load Current.
Two Completely Isolated Outputs can be configured in Series or Parallel to Enhance Voltage or Current Output Capacity Respectively.
Regulation : Voltage (CV) : Load & Line : 0.01 % max.: Current (CC) : Load & Line : 0.05% max.
Ripple : CV : 1 mV (r. m. s.) Max., : CC: 0.03% Amp. (r. m. s.) Max.,
Protected Against Overload & Short Circuit by Means ofAutomatic Crossover Characteristics.
Externally Programmable Output Voltage.
Remote Sensing for Distantly Situated Loads.
Continuous Metering of Output Voltage & Current.
Input Voltage: 230V AC 10%, 50Hz, Single Phase.

Operating Temperature Range: 0 to 550C.

OPTIONAL FACILITIES : (At Extra Cost) :-
Over voltage Protection (Fixed / Variable).
Input Voltage: 115V AC 10%.
Rack-Mounting, Wall Mounting, Base Mounting.
TTL Compatible Active ON / OFF.

MODEL DESCRIPTION MODEL DESCRIPTION
SVP 032001 0 - 32V / 1A SVP 064010 0- 64V / 10A
SVP 032002 0 - 32V / 2A SVP 064015 0-64V / 15A
SVP 032003 0 - 32V / 3A SVP 064020 0- 64V / 20A
SVP 032005 0 - 32V / 5A SVP 064030 0- 64V / 30A
SVP 032010 0 - 32V / 10A SVP 100001 0- 100V / 1A
SVP 032015 0 - 32V / 15A SVP 100002 0- 100V / 2A
SVP 032020 0 - 32V / 20A SVP 100003 0- 100V / 3A
SVP 032030 0 - 32V / 30A SVP 100005 0- 100V / 5A
SVP 064001 0 - 64V / 1A SVP 100010 0- 100V / 10A
SVP 064002 0 - 64V / 2A SVP 100015 0- 100V / 15A
SVP 064003 0 - 64V / 3A SVP 100020 0- 100V / 20A
SVP 064005 0 - 64V / 5A SVP 100030 0- 100V / 30A
SVP  032100 0 - 32V DC / 100A  
 

View Complete Details

Fixed Output Power Supply

Features :-
Fixed Output Voltage (Settable Over 10% of Nominal Output Voltage).
Factory Set or Adjustable Current Limit.
Load & Line Regulation: 0.05%.
Ripple & Noise: 1 mV (r. m. s.) Max.
Protected Against Overload & Short Circuit by Means of Fold back Circuitry.
Crowbar Type Over Voltage Protection at Output (Only for 5V).
Remote Sensing for Distantly Situated Loads for Model above 5 Amp.
Input Voltage: 230V AC 10%, 50Hz, Single Phase.
Operating Temperature Range: 0 to 55C.
OPTIONAL FACILITIES : (At Extra Cost) :-
Metering of Output Voltage & / or Current.
Over voltage Protection
Input Voltage: 115V AC 10%.
Rack-Mounting, Wall Mounting, Base Mounting.
TTL Compatible Active ON / OFF.

MODEL DESCRIPTION MODEL DESCRIPTION
SFL 005002 5V / 2A SFL 024005 24V / 5A
SFL 005004 5V / 4A SFL 024008 24V /8A
SFL 005006 5V / 6A SFL 024010 24V /10A
SFL 005010 5V / 10A SFL 024015 24V / 15A
SFL 005015 5V / 15A SFL 024020 24V / 20A
SFL 005020 5V / 20A SFL 024030 24V / 30A
SFL 012002 12V / 2A SFL 048002 48V / 2A
SFL 012004 12V / 4A SFL 048004 48V / 4A
SFL 012006 12V / 6A SFL 048006 48V / 6A
SFL 012010 12V / 10A SFL 04S008 48V / 8A
SFL 012015 12V / 15A SFL 048010 48V / 10A
SFL 012020 12V / 20A SFL 048012 48V / 12A
SFL 024001 24V / 1A SFL 048015 48V / 15A
SFL 024002 24V / 2A SFL 048020 48V / 20A
SFL 024003 24V / 3A SFL 048030 48V / 30A
View Complete Details

RFI Filter

  • Rated Voltage : 0 to 240V AC / DC.
  • Operating Frequency : 0 to 60 Hz, 1 Phase.
  • DC Galvanic Isolation : 300M Ohm & above between Input / Output Shorted together & Earth, at 500V DC.
  • Break Down Voltage : 1500V AC between Input - Output Shorted together & Earth for 60 Seconds.
  • Leakage Current : 2 x 0.2mA max. At 240V, 50Hz.
  • Voltage Drop : 0.8V r.m.s. Max.

Any special purpose Power Supply which is not observed in this Product range may be due to Mechanical dimensions, Combination of output, Output distribution, Metering Panel layout, Auxiliary alarms and, Indication, Output / Input termination, Addition protections, Mounting etc. can be worked out to fulfill the requirement completely.

MODEL DESCRIPTION
SNF 240005 0 - 5A
SNF 240010 0 - 10A
SNF240015 0 - 15A
SNF 240020 0 - 20A
SNF 240025 0 - 25A
SNF 240030 0 - 30A
CUSTOM BUILT POWER SUPPLY :-
Any special purpose Power Supply which is not observed in this Product range may be due to Mechanical dimensions, Combination of output, Output distribution, Metering Panel layout, Auxiliary alarms and, Indication, Output / Input termination, Addition protections, Mounting etc. can be worked out to fulfill the requirement completely.
Feel Free to contact us for your requirements and we will work out the most suitable system for your application.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us