Our Products
Our product range contains a wide range of Ultrasonic Clamp on Flow Meter, Vibrating Fork Level Switches, Capacitive Level Switches, RF Level Switches and Miniature Float Switches
Ultrasonic Digital Clamp-on flow meter
Advantages:OIML / MID 001 / 2014/32/EC certified
digital signal processing, high noise immunity;
DN range from 10 mm up to 5000 mm;
stable operation in spite of weak signal on aged piping;
reliable metering on fluid parameters alteration;
easy commissioning;
bidirectional flow measurement;
clamp-on and wetted transducers;
no pressure loss in pipeline;
batching mode to measure the dose;
multi-beam measuring;
up to 4 pipes with one electronic unit;
waterproof transducers;
ISO 9001:2008 certified.
Measured Media:
hot and cold process and potable water;
waste water;
acids;
alkalis;
liquid foods.
Specification:
| Parameter | wetted PEA | clamp-on PEA |
| Nominal diameter of the pipeline, DN | 10 5000 | 50 5000 |
| Accuracy, %, with flowrate range from 1:100:- single-beam sounding- two-beam sounding- four-beam sounding | 210, 5 | |
| Flow velocity range, m/s | 0.1 20 | |
| Fluid temperature range, ? | minus 30 160 | minus 30 150 |
| Ambient temperature for transmitter, ? | 0 50 | |
| Maximum pipeline pressure*, MPa/bar | 2.5/25 | - |
| Transmitter / transducers protection | IP54/IP68 | |
| Measurement data logging, number of records:- hourly log- daily log- monthly log- programmable- batching | 1440604814400512 | |
| Power supply, VDC | 24 | |
| Power consumption, VA | under 12 | |
| Transmitter weight, kg | under 3 | |
| Transmitter dimensions, mm | 250 132 90 | |
*- on request is possible to supply pipeline sections with wetted PEAs designed for up to 25 MPa/250 bar pressure.
Outputs:
LCD;
pulse or logic digital output (up to 8 additional digital outputs on request);
RS-232/RS-485 serial interface (ModBus);
0-5, 0-20, or 4-20 mA analog output (on request);