Multipurpose Fire Extinguisher

ABC TYPE FIRE EXTINGUISHER
Store Pressure ( Multipurpose Fire Extinguisher )
"SAFIRE" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER COVERS A, B, C CLASS OF FIRES WHICH INCLUDE PAPERS, WOOD, CLOTH RUBBER, PLASTIC & INFLAMMABLE LIQUID LIKE OIL, PETROL, PAINTS, PETROCHEMICAL PRODUCT, RESINS, GASES IN THE COMPRESSED FROM ACETYLENES, LPG & CNG, ELECTRICAL & SOPHISTICATED ELECTRICAL EQUIPMENT.

Technical Specification
Capacity (in Kg) 500 gms 1 2 5 10
IS Specification 13849 13849 13849 13849 13849
Jet Range ( In Mtrs.) 1.5 2-4 2-4 4-5 <6
Discharge Time (In Sec.) 6-8 8-10 8-10 15-20 23-30
Min. Discharge Quantity 85% 85% 85% 85% 85%
Seal of Aproval ISI ISI ISI ISI ISI
Hydraulic Test Pressure of Cylinder (Kg./Cm2) 30 30 30 30 30
Discharge Outlet Direct Nozzle Direct Nozzle Direct Nozzle Direct Nozzle Direct Nozzle
View Complete Details

Water CO2 Type Fire Extinguisher

WATER CO2 TYPE FIRE EXTINGUISHER FOR "A" CLASS OF FIRE
Store Pressure ( Multipurpose Fire Extinguisher )
"SAFIRE" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER & WATER STORE PRESSURE TYPE PROVIDES SAFETY AGAINST "A" CLASS OF THE FIRE WHICH INVOLVES MATERIAL LIKE WOOD, PAPER, CLOTH, PLASTICS & FIBER, RUBBER ETC.

Technical Specification
Technical Specification Water CO2 Store Pressure Water CO2 Store Water CO2 Store
Capacity (in Ltr) 9 9 50
IS Specification 6234 940 13385
Jet Range ( In Mtrs.) <6 <6 10
Discharge Time (In Sec.) 60-90 60-120 60-180
Min. Discharge Quantity 95% 95% 95%
Seal of Approval ISI ISI -
Hydraulic Test Pressure of 
Cylinder (Kg./Cm2)
30 30 30

View Complete Details

Dry Chemical Powder Type Fire Extinguisher

DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE
"SAFIRE" BIS APPROVED ISI MARK DRY CHEMICAL FIRE EXTINGUISHER CONTROL B & C CLASS OF FIRE LIKE OIL, PETROL AND PETROLEUM PRODUCT, SOLVENT, PAINTS, VARNISHES, CHEMICAL LIQUIDS, ALL FLAMMABLE LIQUIDS & ELECTRICAL FIRE & GAS FIRE, ETC.

Technical Specification
Capacity (in Kg) 5 10 25 50 75
IS Specification 2175 2171 10658 10658 10658
Jet Range ( In Mtrs.) 4-5 <6 <6 8-10 10-12
Discharge Time (In Sec.) 15-20 25-30 25-30 40-50 50-60
Min. Discharge Quantity 90% 90% 85% 85% 85%
Seal of Aproval ISI ISI - - -
Hydraulic Test Pressure of Cylinder (Kg./Cm2) 30 30 30 30 30
View Complete Details

Carbon Dioxide Type Fire Extinguisher

CARBON DIOXIDE TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE
"SAFIRE" CARBON DIOXIDE TYPE FIRE EXTINGUISHER ARE SUITABLE FOR B & C CLASS OF FIRES INVOLVING ALL FLAMMABLE LIQUIDS, GASES, LIVE & DELICATE, MACHINERY FIRES, ELECTRICAL & SOPHISTICATED ELECTRONIC EQUIPMENTS FIRES TRASNFORMER & SWITCH GEAR FIRE. THIS EXTINGUISHER IS APPROVED BY EXPLOSIVE DEPARTMENT, GOVT. OF INDIA, NAGPUR

Technical Specification

 
Capacity (in Kg) 2 3 4.5 6.5 9 22.5
IS Specification 2878 2878 2878 2878 2878 2878
Jet Range ( In Mtrs.) 2 2 2.5-3 2.5-3 2.5-3 2.5-3
Discharge Time (In Sec.) 14-16 16-18 20-24 25-30 30-35 50-60
Min. Discharge Quantity 98% 98% 98% 98% 98% 98%
Hydraulic Test Pressure of Cylinder (Kg./Cm2) 250 250 250 250 250 250
Working Pressure (Kg./Cm2) 60-65 60-65 60-65 60-65 60-65 60-65
View Complete Details

Mechanical Foam (AFFF) Fire Extinguisher

MECHANICAL FOAM (AFFF) FIRE EXTINGUISHER FOR "A" & "B" CLASS OF FIRE
CAUTION : NOT TO BE USED ON ELECTRICAL FIRES
"SAFIRE" MECANICAL FOAM TYPE FIRE EXTINGUISHER IS DESIGNED TO EXTINGUISH A & B CLASS OF FIRE INVOLVING WOOD, PAPER, CLOTH, TEXTILE, STATIONERY & VERY SPECIAL BLANKET EFFECT ON FLAMMABLE & VOLATILE LIQUIDS LIKE OIL, PETROL, KEROSENE, SOLVENT & CHEMICAL, WAX, RESINS ETC.

TECHNICAL SPECIFICATION

Technical Specification MECH. FOAM MECH. FOAM MECH. FOAM STORE PRESSURE
Capacity (in Ltr) 9 50 9
IS Specification 1024 13386 15397
Jet Range ( In Mtrs.) <6 10 <6
Discharge Time (In Sec.) 60-90 60-180 25-60
Min. Discharge Quantity 95% 90% 90%
Hydraulic Test Pressure of Cylinder (Kg./Cm2) 30 30 30
View Complete Details

Automatic Modular Fire Extinguisher

  • Contents : Automatic ABC Dry Power, Dry Chemical Powder, FM-200 etc.
AUTOMATIC MODULAR FIRE EXTINGUISHER A B C E CLASS OF FIRE

Operation :When heat from an uncontrolled fire increases to a pre-set temperature of the unit, the fusible link releases discharging the extiinguishing agent. The releases temperature of the extinguisher (fusible link) can be preset at works ranging from 570c/680c/790c/930c/1400c and so on. They require no external source of energy and it can be operated electrically, manually or mechanically for their operation. (Optionally).Applicability for General Occupancies & Storage Areas like :Storage of Flammabble & Combustible Liquids & Gases, Chemicals, Grain Mill Products, Solids Fuels, Records, Libraries, Museums, Showrooms, Shops, Offices, Residential premises, Workshop, Garages, Paint Booths, Theatre, Radio Rooms TV Stations etc.