Our Products
Our product range contains a wide range of Floor Mounted Gas Chlorinator, Wall Mounted Gas Chlorinator, Cylinder Mounted Gas Chlorinator and Vacuum Chlorinator
Shital Model No (Ranges from FMR-1000 to FMR-3000) is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive acting spring-opposed diaphragm regulators.
Vacuum Regulators
Operate on diaphragm backed by Monel spring vacuum regulator remotely mounted on manifold consisting of electrically operated heater for smooth flow of gas in cold climate; and as such, system remains under vacuum condition till dosing point.
Differential Regulator (optional):
Maintains stedy flow rate and maintains constant vacuum beteween rate valve and flow meter.
Rate Setting :
Manual adjustment at the rate valve located on differential regulator body along with flow indicator.
Capacity :
10 Kg/hr to 120 Kg./Hr. or 10, 000 P.P.D. (Pounds/Chlorine per 24 Hours)
Range :
Within the basic 120 Kg./Hr. Capacity, the SHITAL Chlorinator is capable of operating overflow ranges from 20 to 1, which are dependent upon the type of flow meters used.
Water Requirement :
The water supply flow rate and pressure requirement depend upon the maximum Chlorine capacity and back pressure at the outlet of the ejector. Back pressure includes the pipe functional losses between SHITAL Chlorinator and the point of application, plus existing back pressure at the point of application.
Semi Automatic Operation :
The Chlorine regulator will permit gas flow only when the ejector furnishes sufficient vacuum. To operate the Chlorinator, it is necessary to initiate the ejector water flow. To stop Chlorinator, it is necessary to interrupt the water flow. This 'On/Off' operation makes Chlorinator semiautomatic. it can be accompanied by opening and closing of a solenoid valve in the injector water line.
Remote wall panel mounted Vacuum regulator, Vacuum is controlled by a spring opposed diaphragm via which via the throttling action of the inlet connected valve, reduces the gas from a varying supply pressure to constantly regulated vacuum for safe transport to the point of application.
Pressure relief is provided by a spring loaded diaphragm actuated pressure relief valve The Pressure relief Valve Will be open when the inlet Pressure is excessive. The inlet Valve does not shut off and no vacuum is being Created or is over come. The pressure relief Valve is Connected to the vent. The regulator is equipped with a gas pressure gauge to provide local indication of gas supply status. The pressure gas inlet connection incorporates a lead seal, filter assembly and liquid trap with pad heater
Remote Meter
Shital Model System