Post Buy Requirement
S.M. Engineers
Delhi, India
gstGST : 07APTPN0096B1ZS Verified Add Review

Pump Controllers

3X1-D Smart Pump Controller

  • Model 3X1-D
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Over Voltage
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Pump anti-jamming
  • Under Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
View Complete Details

3X2-P Smart Pump Controller

  • Model 3X2-P
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Pump anti-jamming
  • Over Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch / Level Transmitter
  • Booster – Water supply via Pressure Switch / Pressure Transmitter

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
  • RS 485 Modbus communication 
  • Pot. Free Alarm contact
View Complete Details

3X2-D Smart Pump Controller

  • Model 3X2-D
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Pump anti-jamming
  • Over Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD 
  • Screen Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
  • RS 485 Modbus communication 
  • Pot. Free Alarm contact
View Complete Details

1X1-P Smart Pump Controller

  • Model 1X1-P
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Winding Temperature

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch /Level Transmitter
  • Booster – Water supply via Pressure Switch /Pressure Transmitter

 

Features

  • Graphical backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • RS 485 Modbus communication
View Complete Details

3X2-E Smart Pump Controller

  • Model 3X2-E
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Over Voltage
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Pump anti-jamming
  • Under Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
View Complete Details

3X1-S Smart Pump Controller

  • Model 3X1-S
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 10 – 40 HP (max. up to 45 A)
  • Starting method Star - Delta
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 41
  • Product Dimensions As per rating

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

3M1-E Smart Pump Controller

  • Model 3M1-E
  • Configuration Three Phase – Single Pump for Manual Start & Stop operation
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 80 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
  • In built optional Auto switch
View Complete Details

3X1-P Smart Pump Controller

  • Model 3X1-P
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 20 H.P. (max. up to 32 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Short Circuit
  • Over Voltage Pump Anti-jamming

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float
  • switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch /Level Transmitter
  • Booster – Water supply via Pressure Switch /Pressure Transmitter

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • RS 485 Modbus communication
  • Audio visual alarm against faults 
  • Screen lock in AUTO mode
View Complete Details

1X1-E Smart Pump Controller

  • Model 1X1-E
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 152 x 125 x 70 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch
  • Re-circulation – Asymmetrical ON/OFF timing

 

Features

  • LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

1X2-D Smart Pump Controller

  • Model 1X2-D
  • Configuration Single Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 220V – 50/60 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • Cyclic & Parallel Operation
View Complete Details

1X1-D Smart Pump Controller

  • Model 1X1-D
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 85 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

3X1-E Smart Pump Controller

  • Model 3X1-E
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 80 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

1X1-C Smart Pump Controller

  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Start and Run Capacitor
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • In built auto capacitor switching
View Complete Details

3M1-D Smart Pump Controller

  • Model 3M1-D
  • Configuration Three Phase – Single Pump for Manual Start & Stop operation
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)
  • Short Circuit via 3 Pole MCB

 

Features

  • Graphical Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
  • In built optional Auto switch
  • Last five hours record
  • Pump run hors info
View Complete Details

1X2-C Smart Pump Controller

  • Model 1X2-C
  • Configuration Single Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 2.0 H.P. (max. up to 15 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 350 x 450 x 175 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • Cyclic & Parallel Operation
  • Pot. Free Alarm contact 
  • RS 485 Modbus communication
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Nadeem Mirza & Mr. Sameer Mirza (S.M. Engineers)
  • A-427/28, JJ Colony, Phase - II, Nangloi, Delhi - 110041, India
  • Share us via
  • Call 08069247303 Ext. 779
Supplier of Pump Controllers from Delhi, Delhi by S.M. Engineers
Post Buy Requirement
S.M. Engineers
Delhi, India
gstGST : 07APTPN0096B1ZS Verified Add Review

Pump Controllers #7433340

3X1-D Smart Pump Controller

  • Model 3X1-D
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Over Voltage
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Pump anti-jamming
  • Under Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
View Complete Details

3X2-P Smart Pump Controller

  • Model 3X2-P
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Pump anti-jamming
  • Over Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch / Level Transmitter
  • Booster – Water supply via Pressure Switch / Pressure Transmitter

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
  • RS 485 Modbus communication 
  • Pot. Free Alarm contact
View Complete Details

3X2-D Smart Pump Controller

  • Model 3X2-D
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Pump anti-jamming
  • Over Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD 
  • Screen Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
  • RS 485 Modbus communication 
  • Pot. Free Alarm contact
View Complete Details

1X1-P Smart Pump Controller

  • Model 1X1-P
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Winding Temperature

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch /Level Transmitter
  • Booster – Water supply via Pressure Switch /Pressure Transmitter

 

Features

  • Graphical backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • RS 485 Modbus communication
View Complete Details

3X2-E Smart Pump Controller

  • Model 3X2-E
  • Configuration Three Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 HP (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 415 – 50 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run Over Voltage
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Pump anti-jamming
  • Under Voltage Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Pump Run hours info
  • One touch calibration 
  • Last five faults record
  • Auto recovery against faults 
  • Screen lock in AUTO mode
  • Cyclic and Parallel running 
  • Locking Faulty pump
View Complete Details

3X1-S Smart Pump Controller

  • Model 3X1-S
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 10 – 40 HP (max. up to 45 A)
  • Starting method Star - Delta
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 41
  • Product Dimensions As per rating

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

3M1-E Smart Pump Controller

  • Model 3M1-E
  • Configuration Three Phase – Single Pump for Manual Start & Stop operation
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 80 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
  • In built optional Auto switch
View Complete Details

3X1-P Smart Pump Controller

  • Model 3X1-P
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 20 H.P. (max. up to 32 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run Winding Temperature
  • Current Overload Single Phasing (current sensing)
  • Pump Stalled Reverse Phasing
  • Under Voltage Short Circuit
  • Over Voltage Pump Anti-jamming

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch/Level Transmitter
  • Water Transfer -Underground Tank to Overhead Tank via Float
  • switch/Level Transmitter
  • Drainage – Tank emptying via Float Switch /Level Transmitter
  • Booster – Water supply via Pressure Switch /Pressure Transmitter

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • RS 485 Modbus communication
  • Audio visual alarm against faults 
  • Screen lock in AUTO mode
View Complete Details

1X1-E Smart Pump Controller

  • Model 1X1-E
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 152 x 125 x 70 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch
  • Re-circulation – Asymmetrical ON/OFF timing

 

Features

  • LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

1X2-D Smart Pump Controller

  • Model 1X2-D
  • Configuration Single Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 220V – 50/60 Hz
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • Cyclic & Parallel Operation
View Complete Details

1X1-D Smart Pump Controller

  • Model 1X1-D
  • Configuration Single Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 18 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 85 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

3X1-E Smart Pump Controller

  • Model 3X1-E
  • Configuration Three Phase – Single Pump with In-built Automatic Water Level Controller
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 22
  • Product Dimensions 170 x 155 x 80 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
View Complete Details

1X1-C Smart Pump Controller

  • Rated Output Power 0.5 – 3.0 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Start and Run Capacitor
  • IP Rating IP 54
  • Product Dimensions 302 x 240 x 120 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • In built auto capacitor switching
View Complete Details

3M1-D Smart Pump Controller

  • Model 3M1-D
  • Configuration Three Phase – Single Pump for Manual Start & Stop operation
  • Rated Output Power 1.0 – 10 H.P. (max. up to 22 A)
  • Starting method D.O.L.
  • No. of controlled pumps One
  • Input Supply Voltage AC 415 V– 50 Hz
  • IP Rating IP 54
  • Product Dimensions 250 x 197 x 115 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Single Phasing (current sensing)
  • Short Circuit via 3 Pole MCB

 

Features

  • Graphical Backlit LCD Screen
  • One touch calibration
  • Auto recovery against faults
  • In built optional Auto switch
  • Last five hours record
  • Pump run hors info
View Complete Details

1X2-C Smart Pump Controller

  • Model 1X2-C
  • Configuration Single Phase – Duplex Pump with In-built Automatic Water Level Controller
  • Rated Output Power 0.5 – 2.0 H.P. (max. up to 15 A)
  • Starting method D.O.L.
  • No. of controlled pumps Two (1W+1S)
  • Input Supply Voltage AC 220V – 50/60 Hz
  • Capacitor compatibility Run Capacitor only
  • IP Rating IP 54
  • Product Dimensions 350 x 450 x 175 mm

Protections offered

  • Sensor-less Dry run
  • Current Overload
  • Pump Stalled
  • Under Voltage
  • Over Voltage
  • Short Circuit

 

Water Level Controller – Applications offered

  • Water Supply - Direct Overhead Tank filling via Float switch
  • Water Transfer -Underground Tank to Overhead Tank via Float switch
  • Drainage – Tank emptying via Float Switch
  • Booster – Water supply via Pressure Switch

 

Features

  • Graphical Backlit LCD Screen 
  • Last five faults record
  • One touch calibration 
  • Pump run hours info
  • Auto recovery against faults 
  • Cyclic & Parallel Operation
  • Pot. Free Alarm contact 
  • RS 485 Modbus communication
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Nadeem Mirza & Mr. Sameer Mirza (S.M. Engineers)
  • A-427/28, JJ Colony, Phase - II, Nangloi, Delhi - 110041, India
  • Share us via
  • Call 08069247303 Ext. 779