Our Complete range of products are RPM Chute Level Transmitters and Donnelly Chute Level Transmitters.
This is micro-processor based Donnelly Chute level indictor Transmitter with isolated o/p(4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can be set sensor sensitivity , sensor level selection, sample delay time and relay set point etc. The user can be set level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100%, The instrument have five settable parameters like rL1, rL2, snt, trl, Lst. The Instrument read input level in sequence 1 to 10 if misplaced any level then it will not show above levels.
Parameters :
SNT(sensitivity adjustment Parameter) :In this parameter user can be adjust sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normaly set 100 value of every sensor. If SNT value set 93 then direct on without input connection.
LST (level selection parameter)
Specifications :
Terminal Details
| S1 to S10 | For probe type input level sensor |
|---|---|
| L1 to L10 | Optical digital out put to plc |
| +24vdc | +v common (from PLC) for optical digital output |
| GND | Common terminal of probe sensor (Donnelly chute sensor) |
| o/p 4-20 Ma | mA output (isolated) |
| P | common terminal of Relay |
| N/O | Normaly open terminal of Relay |
| N/C | Normaly close terminal of relay |
| L | Phase of 220v AC @50/60Hz |
| N | Neutral |
| E | Earth |
This is micro-controller based RPM Transmitter with 2 Relay control output. It is designed for settable teeth or pulse(1-99) PNP/NPN type photo sensor or proximity sensor input. User can be adjusting range parameter for required retransmission output (4-20mA) otherwise o/p can be higher than 20mA.The instrument can be display over (over range) message when rpm greater than 9999.
The manual covers all aspects of operation of the instrument. Please read instructions carefully before operating it.