Telescopic Valve Carbon Steel

Telescoping valves are designed to control the height of liquid within a pond, reservoir, or other holding chamber. In modern sewage treatment facilities, water treatment plant one specific use is to control the level of effluent in settling basins. Also called Decanting Valves or Sludge Draw-off Valves, the assembly consists of a drain tube which can slip up and down inside a stationary vertical pipe. Through a lifting device, the tube is raised and lowered to maintain the desired level within the chamber.

View Complete Details

Chemical Dosing System

  • Voltage 380V
  • Power 9-12kw
  • Capacity 100gms/hr to 250 Kgs/hr of chlorine
  • Flow Rate 300 - 30000 T/h
  • Frequency 50/60 Hz
  • Phases 3 phase

The Industries that benefit Chemicals and Fertilizers, Refineries, Petrochemicals, Power stations, Steel Plants, Cement Plants, Pharmaceuticals, Industries, Pesticide Industries, Food Industries, Textiles, Paper and Pulp Industries, Sugar Plants, Municipalities, Corporations, Townships, Water Boards, Theme Parks, Hotels, Apartment Complexes, etc .

  • We manufacturing wide range of chlorinator and accessories
  • Vacuum feed type gas chlorinator
  • Capacity ranges from 100 Gms/hr to 250 Kgs/hr of chlorine.
  • Simple Design, Easy to Operate and Efficient Performance
View Complete Details

Pressure Filter / Iron Removal Plant

AUXILIARY CONTAINER VALVE WITH YOKE



An additional valve assembly mounted with a yoke on the container valve . this valve eliminates the possibility of leakage from damaged container valve




View Complete Details

Tonner Mounted Ammoniator

  • Capacity 100gms/hr to 5 Kgs/hr of chlorine
  • Type Tonner Mounted
  • Accuracy + - 4% of Max Flowmeter capacity
  • Voltage 240 V AC or 24 V DC
  • Power Hydraulic
  • Fluid Media Chlorine Gas

The Industries that benefit Chemicals and Fertilizers, Refineries, Petrochemicals, Power stations, Steel Plants, Cement Plants, Pharmaceuticals, Industries, Pesticide Industries, Food Industries, Textiles, Paper and Pulp Industries, Sugar Plants, Municipalities, Corporations, Townships, Water Boards, Theme Parks, Hotels, Apartment Complexes, swimming pool water distubution system etc.

  • We manufacturing wide range of chlorinator and accessories
  • Vacuum feed type gas chlorinator
  • Capacity range from 100 gms /hr to 5 kg/hr .
  • Simple Design, Easy to Operate and Efficient Performance


Principle of Operation
Motive Water (water at high pressure) passes through the injector to produce vacuum. This vacuum extends upto Vacuum Regulator. The chlorine gas received (from Tonnes / Cylinders under pressure this regulator is in build regulating system when we control the flow of chlorine through flow control valve the pressure regulate automatic and gas flow through a Rotameter to injector where chlorine and water mixes .

Flow Meter

  • Indicates
  • Directly the flow Chlorine gas in terms of Grams/kilograms per hour.
  • Made of Borosilicate glass and calibrated for 0.1, 0.2, 0.5, 1, 2, 3, 5, 6 10, 15, 20, 25, 30, 40, 50, 75, 90, 110, 150, 200, 250 kgs/hr.
  • Accuracy is +- 2 TO 4% of indicated flow.


Safety Valves - The system is provided with Pressure Relief Valve. Vacuum Relief Valve, Check Valve and Emergency Drain Relief Valve.

Flow control valve

  • Manual control valve for manual chlorinator
  • Electical actuator with flow control valve for automatic chlorinator


Injector- Fixed-throat

MOC :- PVC/PVC FRP

Material supplied with system

  • Roller support for tonner only
  • Yoke
  • Vacuum regulator
  • Flow meter
  • Flow control valve
  • Injector
  • Check valve with emergency drain valve.
View Complete Details

Auxiliary Container Valve

  • Type Auxiliary Container Valve with Yoke
  • Color Silver
  • Material Steel
  • Finishing Polished
  • Features Perfect Shape, Abrasion Resistant
  • Grade Manual

An additional valve assembly mounted with a yoke on the container valve . this valve eliminates the possibility of leakage from damaged container valve.

View Complete Details

Iron Removal Plant

  • Automatic Grade Automatic, Fully Automatic, Semi Automatic
  • Driven Type Electric
  • Capacity 50T/Hr
  • Capacity 500 - 1, 00, 000 LPH
  • Body Material FRP/ MS/ SS
  • Motive Force Pressure
View Complete Details

Evaporator / Steam Hated Vaporizer

  • Gasket lead sheet – cut gasket
  • Gasket asbestos
  • Tube ASTM – A – 106, Gr.B
  • Flanges ASTM – A – 105.
  • Bolts IS : 1364 (1967) HEAT TRETED TO 8.8 CONDITION
  • Pipe ASTM – A – 106, Gr.B
  • Suction trap ASTM – A – 106, Gr.B
  • Baffle IS – 2062
  • Shell ASTM – A – 106, Gr.B
  • Flanges IS – 2062
  • Bolts steel

SUN ENGINEERING SERVICE manufactures Evaporators for Chlorine, Sulphur Dioxide and Ammonia. The capacity ranges are from 20 kgs/hr to 3000 kgs /hr. Evaporators are classified into two categories depending on type of energy used for vaporizing, namely



  • Electrically heated Evaporator CAPACITY 200 KG/HR MAX

  • Steam heated Evaporator CAPACITY 3000 KG/HR MAX


VAPOURIZER is of heavy duty construction with all pressure parts in contact with chlorine liquid or gas of extra heavy pipe with a minimum of 3 mm corrosion allowance on chlorine side and 1.5mm corrosion allowance on steam side.x





Operating principle

In operation the liquid is introduced through liquid inlet which is piped to the bottom of the vapourizer tube by a dip pipe. Here the liquid rises to contact sufficient surface to supply vapour demand rate. After equilibrium is reached vapourizer operates at essentially liquid line pressure As gas demand is reduced. Vapourizer pressure raises, reducing the flow of liquid feed. On sudden shut down of gas valve, liquid Would be forced out of vaporizing chamber back to the container.


With evaporation the vapour raises through the vapour baffle to the super heating chamber. Enters the indicated parts of the suction trap and leaves through the gas outlet.


The steam chamber has nipple connections for steam inlet condensate outlet pressure gauge and pressure relief valve, insulation on shell must be done by the client.


Two numbers single tonner connection manifold are provided. When first tonner is getting empty, second tonner line will open automatically through inter lock system for which 3 way ball valve with electric actuator (8) and pressure switches (6) are installed for auto operation chlorine tonner valve and corresponding valves should be kept open.
Note :- before admitting liquid chlorine to vaporizer system. Steam shall be admitted first. So that vaporizer body will be heated and ready to receive liquid chlorine. The steam pressure shall be 1.0 kg/cm unless steam pressure is available in vaporizer steam chamber. Automatic shut off valve (8) on manifold and auto shut off valve (19) on chlorine gas line will not open so that flooding of liquid chlorine is avoided .from manifold liquid chlorine will be fed to vaporizer through dip pipe. As soon as liquid chlorine is fed, gas is formed . please note that chlorine gas coming out will be at least 3 to 5c above room temperature.


The chlorine gas coming out of vaporizer passes through chlorine gas filter (16) where all impurities like ferric chloride will be trapped. The filtered gas will pass through automatic shut off valve (19) which is inter locked with pressure switch on steam chamber. As the gas reaches pressure reducing valve where chlorine gas pressure will be reduced from 8 kg/cm to 0.5 to 3 kg/cm. the outlet of pressure reducing valve is taken to system bye oass valves (17) are provided in case pressure reducing valve is taken for maintenance.


Excess pressure:-

Chlorine vaporizer should be equipped with pressure relief valve to protect the system against rupture spring loaded safety valve are combined in series with a frangible disc ( rupture disc). The rupture disc is 19 to 21 kg//cm rupture pressure. Because of this pressure relief valve opens when reupture disc burst vent connection shall be taken to chlorine absorption system.


Expansion chamber on liquid chlorine line:

During operation incase automatic shut off valve closes pressure will be developed in liquid chlorine line. In order to reduce the pressure in the line expansion chamber with rupture disc is provided. The repture disc bursts at 19 to 21 kg/cm and liquid chlorine enters empty cylinder. Because of this action pressure in the line reduces.





DESIGN TEMPERATURE & PRESSURE FOR TUBE.

The evaporator tube is constructed of specified materials for 64.5 kg/cm (920 psi ) pressure and 120 c (250 f ) temperature. Flanges are of class 300 ( ANSI B 16.5 1968 ) and the pipe is of sch 80 (ASA B 36.10 1950).


HYDRAULICS TEST PRESSURE FOR TUBE

102 kg/cm. (1450 psi ) as per ANSI B 16.5 1968.






View Complete Details

Steam Hated Vaporizer

  • Material Steel
  • Feature Durable, Easy To Use, Light Weight, Rust Proof
  • Driven Type Electric
  • Application Industrial
  • Capacity Ranges 20 kgs/hr to 3000 kgs /hr
  • Hydraulics Test Pressure for Tube 102 kg/cm². (1450 psi ) as per ANSI B 16.5 – 1968.

Sun Engineering Service manufactures Evaporators for Chlorine, Sulphur Dioxide and Ammonia. The capacity ranges are from 20 kgs/hr to 3000 kgs /hr. Evaporators are classified into two categories depending on type of energy used for vaporizing, namely

  • Electrically heated Evaporator Capacity 200 KG/HR MAX
  • Steam heated Evaporator Capacity 3000 KG/HR MAX


VAPOURIZER is of heavy duty construction with all pressure parts in contact with chlorine liquid or gas of extra heavy pipe with a minimum of 3 mm corrosion allowance on chlorine side and 1.5mm corrosion allowance on steam side.

Operating principle
In operation the liquid is introduced through liquid inlet which is piped to the bottom of the vapourizer tube by a dip pipe. Here the liquid rises to contact sufficient surface to supply vapour demand rate. After equilibrium is reached vapourizer operates at essentially liquid line pressure As gas demand is reduced. Vapourizer pressure raises, reducing the flow of liquid feed. On sudden shut down of gas valve, liquid Would be forced out of vaporizing chamber back to the container.
With evaporation the vapour raises through the vapour baffle to the super heating chamber. Enters the indicated parts of the suction trap and leaves through the gas outlet.
The steam chamber has nipple connections for steam inlet condensate outlet pressure gauge and pressure relief valve, insulation on shell must be done by the client.

Design Temperature & Pressure for Tube.
The evaporator tube is constructed of specified materials for 64.5 kg/cm² (920 psi ) pressure and 120 °c (250 °f ) temperature. Flanges are of class 300 ( ANSI B 16.5 – 1968 ) and the pipe is of sch 80 (ASA B 36.10 – 1950).

Hydraulics Test Pressure for Tube
102 kg/cm². (1450 psi ) as per ANSI B 16.5 – 1968.

Description of Steam Heated Vapourizer

  • Two numbers single tonner connection manifold are provided. When first tonner is getting empty, second tonner line will open automatically through inter lock system for which 3 – way ball valve with electric actuator (8) and pressure switches (6) are installed for auto operation chlorine tonner valve and corresponding valves should be kept open.
  • Note :- before admitting liquid chlorine to vaporizer system. Steam shall be admitted first. So that vaporizer body will be heated and ready to receive liquid chlorine. The steam pressure shall be 1.0 kg/cm² unless steam pressure is available in vaporizer steam chamber. Automatic shut off valve (8) on manifold and auto shut off valve (19) on chlorine gas line will not open so that flooding of liquid chlorine is avoided .from manifold liquid chlorine will be fed to vaporizer through dip pipe. As soon as liquid chlorine is fed, gas is formed . please note that chlorine gas coming out will be at least 3 to 5°c above room temperature.
  • The chlorine gas coming out of vaporizer passes through chlorine gas filter (16) where all impurities like ferric chloride will be trapped. The filtered gas will pass through automatic shut off valve (19) which is inter locked with pressure switch on steam chamber. As the gas reaches pressure reducing valve where chlorine gas pressure will be reduced from 8 kg/cm² to 0.5 to 3 kg/cm². the outlet of pressure reducing valve is taken to system bye oass valves (17) are provided in case pressure reducing valve is taken for maintenance.


Excess pressure:-
Chlorine vaporizer should be equipped with pressure relief valve to protect the system against rupture spring loaded safety valve are combined in series with a frangible disc ( rupture disc). The rupture disc is 19 to 21 kg//cm² rupture pressure. Because of this pressure relief valve opens when reupture disc burst vent connection shall be taken to chlorine absorption system.


Expansion chamber on liquid chlorine line:
During operation incase automatic shut off valve closes pressure will be developed in liquid chlorine line. In order to reduce the pressure in the line expansion chamber with rupture disc is provided. The repture disc bursts at 19 to 21 kg/cm² and liquid chlorine enters empty cylinder. Because of this action pressure in the line reduces.

View Complete Details

Chlorine Tonner

The Lifting Beam Is Very Essential For Safe Handing Of Chlorine Container The Lifting Beam Can Also Be Fitted With Crane Weighing Scale To Weigh The Chlorine Ton Container
View Complete Details

Flexible Copper Connector With PVC Coating



FLEXIBLE COPPER CONNECTOR OFFERING POSITIVE CONNECTION BETWEEN TONNER AND THE MANIFOLD VALVES



View Complete Details

Copper Flexible Connector With PVC Coating

  • Type Flexible Connector
  • Material Copper
  • Application Fittings Use, Pipe Use
  • Color White
  • Feature Easy To Connect, Proper Working, Superior Finish
  • Surface Treatment PVC Coating

Flexible Copper Connector – Offering Positive Connection Between Tonner and the Manifold Valves

View Complete Details

Copper Flexible Connector Without PVC Coating

  • Type Flexible Connector
  • Material Copper
  • Application Fittings Use, Pipe Use
  • Color White
  • Feature Easy To Connect, Proper Working, Water Proof
  • Surface Treatment PVC Coated

Flexible Copper Connector – Offering Positive Connection Between Tonner and the Manifold Valves

View Complete Details

Auto Change Over System

In order to have uninterrupted chlorine gas supply to chlorination system necessary manifolds.Motorised valves and control panel are provided. Chlorine tonner are connected to manifold in which pressure gauge and pressure switch are installed. Pressure gauge indicates the chlorine tonner pressure and pressure switch actuate the electrically operated ball valve. Pressure switch is set at 1.0 kg/cm that means chlorine cylinder is getting empty.


Filled tonner connected to manifold. All tonners valve are kept opened so that manifolds are under pressurized condition. Switch on the auto change over panel and keep the selector switch in auto mode now as soon as panel is energized electrically operated valve manifold I will open first. Even though manifold ll is pressurized , manifold ll side valve will not operate due to inter lock system.


As plant is in operation, chlorine gas will be consumed and tonner pressure may be coming down.When pressure switch actuator and alarm will come and electrically operated ball valve on manifold l will close and valve on manifold ll will open simultaneously. This system will be in operation till chlorine gas pressure is above 1.0 kg/cm at the manifold. During this period fresh filled cylinders may be connected to manifold and kept ready for operation. As explained earlier, chlorine pressure started going below 1.0 kg/cm, alarm will be there and manifold l valve in opened thus the operation of auto change over system continues.


NOTE

:- kindly note that when the manifold pressure is 1.0 kg/cm the chlorine tonner is not fully empty there will be at least one or two kg of chlorine will be available. It is not advisable to send chlorine cylinders for refilling with so much of chlorine left over. This left over chlorine shall be exhausted by keeping auto/manual selector switch in manual mode and operate corresponding push button stations and electrically operated valve can be opened. Keep the valve in open position till chlorine pressure comes to 0.2 kg/cm . pressing off push button, valve will be closed. Similar way manifold ll side shall be operated. During this operation no need of opening bypass valves. During manifold-ll is in operation fresh filled tonner may be connected to manifold l and kept ready for auto operation.

View Complete Details

Automatic Changeover System

  • Power Source Electric
  • Voltage Level Low-Voltage, High-Voltage, Medium-Voltage
  • Frequency 50Hz
  • Fluid Media Chlorine Gas

In order to have uninterrupted chlorine gas supply to chlorination system necessary manifolds.Motorised valves and control panel are provided. Chlorine tonner are connected to manifold in which pressure gauge and pressure switch are installed. Pressure gauge indicates the chlorine tonner pressure and pressure switch actuate the electrically operated ball valve. Pressure switch is set at 1.0 kg/cm that means chlorine cylinder is getting empty.

Filled tonner connected to manifold. All tonners valve are kept opened so that manifolds are under pressurized condition. Switch on the auto change over panel and keep the selector switch in auto mode now as soon as panel is energized electrically operated valve manifold I will open first. Even though manifold ll is pressurized , manifold ll side valve will not operate due to inter lock system.

As plant is in operation, chlorine gas will be consumed and tonner pressure may be coming down.When pressure switch actuator and alarm will come and electrically operated ball valve on manifold l will close and valve on manifold ll will open simultaneously. This system will be in operation till chlorine gas pressure is above 1.0 kg/cm at the manifold. During this period fresh filled cylinders may be connected to manifold and kept ready for operation. As explained earlier, chlorine pressure started going below 1.0 kg/cm, alarm will be there and manifold l valve in opened thus the operation of auto change over system continues.

Note :- Kindly note that when the manifold pressure is 1.0 kg/cm the chlorine tonner is not fully empty there will be at least one or two kg of chlorine will be available. It is not advisable to send chlorine cylinders for refilling with so much of chlorine left over. This left over chlorine shall be exhausted by keeping auto/manual selector switch in manual mode and operate corresponding push button stations and electrically operated valve can be opened. Keep the valve in open position till chlorine pressure comes to 0.2 kg/cm . pressing off push button, valve will be closed. Similar way manifold ll side shall be operated. During this operation no need of opening bypass valves. During manifold-ll is in operation fresh filled tonner may be connected to manifold l and kept ready for auto operation.

View Complete Details

Chlorination Systems

38,000 /Set Get Latest Price
see for detail cylinder mounted chlorination system
our range of cylinder mounted chlorinator up to 5 kg/hr
View Complete Details

Safety Eye Wash And Shower

  • Shower Extra large drench shower head made of highly visible yellow ABS plastics
  • Pipe ISI marked GI pipe with powder coating for anti-corrosion
  • Valve SS stay open ball valve with yellow ABS push plate
  • Bowl Receptor bowl made of ABS and highly resistant to acid, alkali and oil among others.
  • Activation For shower – Pull rod & For eyewash – Push plate
  • Water inlet and drain 1-1/4 inches BSP
  • Standard IS: 10592:1982

Safety Shower and eyewash operates independently by pull rod and push lever


Automiser heads : Twin soft flow automiser head which has aerators to control the stream straightness and diameter, thus reducing splash by aerating the stream. It also controls to save water and reduce energy costs. The twin flow has cover which protects from dust and opens with water pressure.

View Complete Details

Eye Wash Safety Showers

  • Type Safety Shower
  • Material Stainless Steel
  • Color Multi Colour
  • Finishing Polished
  • Feature Good Quality, Hard Structure, Rust Proof
  • Finishing Color Coated
  • Water inlet and drain 1-1/4 inches BSP

Description

  • Safety Shower and eyewash operates independently by pull rod, hand push lever and foot lever
  • Shower - Extra large drench shower head made of highly visible yellow ABS plastics
  • Pipe - ISI marked GI pipe with powder coating for anti-corrosion
  • Valve - SS stay open ball valve with yellow ABS push plate
  • Bowl - Receptor bowl made of ABS and highly resistant to acid, alkali and oil among others.
  • Automiser heads - Twin soft flow automiser head which has aerators to control the stream straightness and diameter, thus reducing splash by aerating the stream. It also controls to save water and reduce energy costs. The twin flow has cover which protects from dust and opens with water pressure
  • Activation - For shower – Pull rod; For eyewash – Push plate/ Foot paddle
  • Water inlet and drain - 1-1/4 inches BSP
  • Standard - IS- 10592:1982
View Complete Details

Trunnion Roller



These help in the proper placement of tonners and to rotate the ton container easily for positioning the gas valves




View Complete Details

Trunnion Roller Support

  • Type Roller Support
  • Material Iron, Metal
  • Application Industrial
  • Feature Corrosion Resistance, Heavy Weight Bearing Capacity, High Quality, Non Breakable
  • Finishing Polished
  • Technics Yellow Zinc Plated

These help in the proper placement of tonners and to rotate the ton container easily for positioning the gas valves.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. K. Kesav Sankar (Sun Engineering Services)
  • No. 20 Shreenathji, Industrial Estate, Near Nikol Ring Road, Near Katawada GIDC, Odhav, Ahmedabad, Gujarat - 382330
  • http://www.sunengineeringservices.com
  • Share us via
  • Call 08069247353 Ext. 119
List of Other Products by Sun Engineering Services from Ahmedabad, Gujarat.
Post Buy Requirement
Sun Engineering Services
Ahmedabad, Gujarat, India
gstGST : 24AEWPC2292L1Z4 Verified Add Review

Other Products / Services #1984975

Telescopic Valve Carbon Steel

Telescoping valves are designed to control the height of liquid within a pond, reservoir, or other holding chamber. In modern sewage treatment facilities, water treatment plant one specific use is to control the level of effluent in settling basins. Also called Decanting Valves or Sludge Draw-off Valves, the assembly consists of a drain tube which can slip up and down inside a stationary vertical pipe. Through a lifting device, the tube is raised and lowered to maintain the desired level within the chamber.

View Complete Details

Chemical Dosing System

  • Voltage 380V
  • Power 9-12kw
  • Capacity 100gms/hr to 250 Kgs/hr of chlorine
  • Flow Rate 300 - 30000 T/h
  • Frequency 50/60 Hz
  • Phases 3 phase

The Industries that benefit Chemicals and Fertilizers, Refineries, Petrochemicals, Power stations, Steel Plants, Cement Plants, Pharmaceuticals, Industries, Pesticide Industries, Food Industries, Textiles, Paper and Pulp Industries, Sugar Plants, Municipalities, Corporations, Townships, Water Boards, Theme Parks, Hotels, Apartment Complexes, etc .

  • We manufacturing wide range of chlorinator and accessories
  • Vacuum feed type gas chlorinator
  • Capacity ranges from 100 Gms/hr to 250 Kgs/hr of chlorine.
  • Simple Design, Easy to Operate and Efficient Performance
View Complete Details

Pressure Filter / Iron Removal Plant

AUXILIARY CONTAINER VALVE WITH YOKE

An additional valve assembly mounted with a yoke on the container valve . this valve eliminates the possibility of leakage from damaged container valve

View Complete Details

Tonner Mounted Ammoniator

  • Capacity 100gms/hr to 5 Kgs/hr of chlorine
  • Type Tonner Mounted
  • Accuracy + - 4% of Max Flowmeter capacity
  • Voltage 240 V AC or 24 V DC
  • Power Hydraulic
  • Fluid Media Chlorine Gas

The Industries that benefit Chemicals and Fertilizers, Refineries, Petrochemicals, Power stations, Steel Plants, Cement Plants, Pharmaceuticals, Industries, Pesticide Industries, Food Industries, Textiles, Paper and Pulp Industries, Sugar Plants, Municipalities, Corporations, Townships, Water Boards, Theme Parks, Hotels, Apartment Complexes, swimming pool water distubution system etc.

  • We manufacturing wide range of chlorinator and accessories
  • Vacuum feed type gas chlorinator
  • Capacity range from 100 gms /hr to 5 kg/hr .
  • Simple Design, Easy to Operate and Efficient Performance


Principle of OperationMotive Water (water at high pressure) passes through the injector to produce vacuum. This vacuum extends upto Vacuum Regulator. The chlorine gas received (from Tonnes / Cylinders under pressure this regulator is in build regulating system when we control the flow of chlorine through flow control valve the pressure regulate automatic and gas flow through a Rotameter to injector where chlorine and water mixes .

Flow Meter

  • Indicates
  • Directly the flow Chlorine gas in terms of Grams/kilograms per hour.
  • Made of Borosilicate glass and calibrated for 0.1, 0.2, 0.5, 1, 2, 3, 5, 6 10, 15, 20, 25, 30, 40, 50, 75, 90, 110, 150, 200, 250 kgs/hr.
  • Accuracy is +- 2 TO 4% of indicated flow.

Safety Valves - The system is provided with Pressure Relief Valve. Vacuum Relief Valve, Check Valve and Emergency Drain Relief Valve.

Flow control valve

  • Manual control valve for manual chlorinator
  • Electical actuator with flow control valve for automatic chlorinator


Injector- Fixed-throat

MOC :- PVC/PVC FRP

Material supplied with system

  • Roller support for tonner only
  • Yoke
  • Vacuum regulator
  • Flow meter
  • Flow control valve
  • Injector
  • Check valve with emergency drain valve.
View Complete Details

Auxiliary Container Valve

  • Type Auxiliary Container Valve with Yoke
  • Color Silver
  • Material Steel
  • Finishing Polished
  • Features Perfect Shape, Abrasion Resistant
  • Grade Manual

An additional valve assembly mounted with a yoke on the container valve . this valve eliminates the possibility of leakage from damaged container valve.

View Complete Details

Iron Removal Plant

  • Automatic Grade Automatic, Fully Automatic, Semi Automatic
  • Driven Type Electric
  • Capacity 50T/Hr
  • Capacity 500 - 1, 00, 000 LPH
  • Body Material FRP/ MS/ SS
  • Motive Force Pressure
View Complete Details

Evaporator / Steam Hated Vaporizer

  • Gasket lead sheet – cut gasket
  • Gasket asbestos
  • Tube ASTM – A – 106, Gr.B
  • Flanges ASTM – A – 105.
  • Bolts IS : 1364 (1967) HEAT TRETED TO 8.8 CONDITION
  • Pipe ASTM – A – 106, Gr.B
  • Suction trap ASTM – A – 106, Gr.B
  • Baffle IS – 2062
  • Shell ASTM – A – 106, Gr.B
  • Flanges IS – 2062
  • Bolts steel

SUN ENGINEERING SERVICE manufactures Evaporators for Chlorine, Sulphur Dioxide and Ammonia. The capacity ranges are from 20 kgs/hr to 3000 kgs /hr. Evaporators are classified into two categories depending on type of energy used for vaporizing, namely

  • Electrically heated Evaporator CAPACITY 200 KG/HR MAX
  • Steam heated Evaporator CAPACITY 3000 KG/HR MAX

VAPOURIZER is of heavy duty construction with all pressure parts in contact with chlorine liquid or gas of extra heavy pipe with a minimum of 3 mm corrosion allowance on chlorine side and 1.5mm corrosion allowance on steam side.x

Operating principle

In operation the liquid is introduced through liquid inlet which is piped to the bottom of the vapourizer tube by a dip pipe. Here the liquid rises to contact sufficient surface to supply vapour demand rate. After equilibrium is reached vapourizer operates at essentially liquid line pressure As gas demand is reduced. Vapourizer pressure raises, reducing the flow of liquid feed. On sudden shut down of gas valve, liquid Would be forced out of vaporizing chamber back to the container.

With evaporation the vapour raises through the vapour baffle to the super heating chamber. Enters the indicated parts of the suction trap and leaves through the gas outlet.

The steam chamber has nipple connections for steam inlet condensate outlet pressure gauge and pressure relief valve, insulation on shell must be done by the client.

Two numbers single tonner connection manifold are provided. When first tonner is getting empty, second tonner line will open automatically through inter lock system for which 3 way ball valve with electric actuator (8) and pressure switches (6) are installed for auto operation chlorine tonner valve and corresponding valves should be kept open.Note :- before admitting liquid chlorine to vaporizer system. Steam shall be admitted first. So that vaporizer body will be heated and ready to receive liquid chlorine. The steam pressure shall be 1.0 kg/cm unless steam pressure is available in vaporizer steam chamber. Automatic shut off valve (8) on manifold and auto shut off valve (19) on chlorine gas line will not open so that flooding of liquid chlorine is avoided .from manifold liquid chlorine will be fed to vaporizer through dip pipe. As soon as liquid chlorine is fed, gas is formed . please note that chlorine gas coming out will be at least 3 to 5c above room temperature.

The chlorine gas coming out of vaporizer passes through chlorine gas filter (16) where all impurities like ferric chloride will be trapped. The filtered gas will pass through automatic shut off valve (19) which is inter locked with pressure switch on steam chamber. As the gas reaches pressure reducing valve where chlorine gas pressure will be reduced from 8 kg/cm to 0.5 to 3 kg/cm. the outlet of pressure reducing valve is taken to system bye oass valves (17) are provided in case pressure reducing valve is taken for maintenance.

Excess pressure:-

Chlorine vaporizer should be equipped with pressure relief valve to protect the system against rupture spring loaded safety valve are combined in series with a frangible disc ( rupture disc). The rupture disc is 19 to 21 kg//cm rupture pressure. Because of this pressure relief valve opens when reupture disc burst vent connection shall be taken to chlorine absorption system.

Expansion chamber on liquid chlorine line:

During operation incase automatic shut off valve closes pressure will be developed in liquid chlorine line. In order to reduce the pressure in the line expansion chamber with rupture disc is provided. The repture disc bursts at 19 to 21 kg/cm and liquid chlorine enters empty cylinder. Because of this action pressure in the line reduces.

DESIGN TEMPERATURE & PRESSURE FOR TUBE.

The evaporator tube is constructed of specified materials for 64.5 kg/cm (920 psi ) pressure and 120 c (250 f ) temperature. Flanges are of class 300 ( ANSI B 16.5 1968 ) and the pipe is of sch 80 (ASA B 36.10 1950).

HYDRAULICS TEST PRESSURE FOR TUBE

102 kg/cm. (1450 psi ) as per ANSI B 16.5 1968.

View Complete Details

Steam Hated Vaporizer

  • Material Steel
  • Feature Durable, Easy To Use, Light Weight, Rust Proof
  • Driven Type Electric
  • Application Industrial
  • Capacity Ranges 20 kgs/hr to 3000 kgs /hr
  • Hydraulics Test Pressure for Tube 102 kg/cm². (1450 psi ) as per ANSI B 16.5 – 1968.

Sun Engineering Service manufactures Evaporators for Chlorine, Sulphur Dioxide and Ammonia. The capacity ranges are from 20 kgs/hr to 3000 kgs /hr. Evaporators are classified into two categories depending on type of energy used for vaporizing, namely

  • Electrically heated Evaporator Capacity 200 KG/HR MAX
  • Steam heated Evaporator Capacity 3000 KG/HR MAX

VAPOURIZER is of heavy duty construction with all pressure parts in contact with chlorine liquid or gas of extra heavy pipe with a minimum of 3 mm corrosion allowance on chlorine side and 1.5mm corrosion allowance on steam side.

Operating principleIn operation the liquid is introduced through liquid inlet which is piped to the bottom of the vapourizer tube by a dip pipe. Here the liquid rises to contact sufficient surface to supply vapour demand rate. After equilibrium is reached vapourizer operates at essentially liquid line pressure As gas demand is reduced. Vapourizer pressure raises, reducing the flow of liquid feed. On sudden shut down of gas valve, liquid Would be forced out of vaporizing chamber back to the container.With evaporation the vapour raises through the vapour baffle to the super heating chamber. Enters the indicated parts of the suction trap and leaves through the gas outlet.The steam chamber has nipple connections for steam inlet condensate outlet pressure gauge and pressure relief valve, insulation on shell must be done by the client.

Design Temperature & Pressure for Tube.The evaporator tube is constructed of specified materials for 64.5 kg/cm² (920 psi ) pressure and 120 °c (250 °f ) temperature. Flanges are of class 300 ( ANSI B 16.5 – 1968 ) and the pipe is of sch 80 (ASA B 36.10 – 1950).

Hydraulics Test Pressure for Tube102 kg/cm². (1450 psi ) as per ANSI B 16.5 – 1968.

Description of Steam Heated Vapourizer

  • Two numbers single tonner connection manifold are provided. When first tonner is getting empty, second tonner line will open automatically through inter lock system for which 3 – way ball valve with electric actuator (8) and pressure switches (6) are installed for auto operation chlorine tonner valve and corresponding valves should be kept open.
  • Note :- before admitting liquid chlorine to vaporizer system. Steam shall be admitted first. So that vaporizer body will be heated and ready to receive liquid chlorine. The steam pressure shall be 1.0 kg/cm² unless steam pressure is available in vaporizer steam chamber. Automatic shut off valve (8) on manifold and auto shut off valve (19) on chlorine gas line will not open so that flooding of liquid chlorine is avoided .from manifold liquid chlorine will be fed to vaporizer through dip pipe. As soon as liquid chlorine is fed, gas is formed . please note that chlorine gas coming out will be at least 3 to 5°c above room temperature.
  • The chlorine gas coming out of vaporizer passes through chlorine gas filter (16) where all impurities like ferric chloride will be trapped. The filtered gas will pass through automatic shut off valve (19) which is inter locked with pressure switch on steam chamber. As the gas reaches pressure reducing valve where chlorine gas pressure will be reduced from 8 kg/cm² to 0.5 to 3 kg/cm². the outlet of pressure reducing valve is taken to system bye oass valves (17) are provided in case pressure reducing valve is taken for maintenance.


Excess pressure:-Chlorine vaporizer should be equipped with pressure relief valve to protect the system against rupture spring loaded safety valve are combined in series with a frangible disc ( rupture disc). The rupture disc is 19 to 21 kg//cm² rupture pressure. Because of this pressure relief valve opens when reupture disc burst vent connection shall be taken to chlorine absorption system.


Expansion chamber on liquid chlorine line:During operation incase automatic shut off valve closes pressure will be developed in liquid chlorine line. In order to reduce the pressure in the line expansion chamber with rupture disc is provided. The repture disc bursts at 19 to 21 kg/cm² and liquid chlorine enters empty cylinder. Because of this action pressure in the line reduces.

View Complete Details

Chlorine Tonner

The Lifting Beam Is Very Essential For Safe Handing Of Chlorine Container The Lifting Beam Can Also Be Fitted With Crane Weighing Scale To Weigh The Chlorine Ton Container
View Complete Details

Flexible Copper Connector With PVC Coating

FLEXIBLE COPPER CONNECTOR OFFERING POSITIVE CONNECTION BETWEEN TONNER AND THE MANIFOLD VALVES

View Complete Details

Copper Flexible Connector With PVC Coating

  • Type Flexible Connector
  • Material Copper
  • Application Fittings Use, Pipe Use
  • Color White
  • Feature Easy To Connect, Proper Working, Superior Finish
  • Surface Treatment PVC Coating

Flexible Copper Connector – Offering Positive Connection Between Tonner and the Manifold Valves

View Complete Details

Copper Flexible Connector Without PVC Coating

  • Type Flexible Connector
  • Material Copper
  • Application Fittings Use, Pipe Use
  • Color White
  • Feature Easy To Connect, Proper Working, Water Proof
  • Surface Treatment PVC Coated

Flexible Copper Connector – Offering Positive Connection Between Tonner and the Manifold Valves

View Complete Details

Auto Change Over System

In order to have uninterrupted chlorine gas supply to chlorination system necessary manifolds.Motorised valves and control panel are provided. Chlorine tonner are connected to manifold in which pressure gauge and pressure switch are installed. Pressure gauge indicates the chlorine tonner pressure and pressure switch actuate the electrically operated ball valve. Pressure switch is set at 1.0 kg/cm that means chlorine cylinder is getting empty.

Filled tonner connected to manifold. All tonners valve are kept opened so that manifolds are under pressurized condition. Switch on the auto change over panel and keep the selector switch in auto mode now as soon as panel is energized electrically operated valve manifold I will open first. Even though manifold ll is pressurized , manifold ll side valve will not operate due to inter lock system.

As plant is in operation, chlorine gas will be consumed and tonner pressure may be coming down.When pressure switch actuator and alarm will come and electrically operated ball valve on manifold l will close and valve on manifold ll will open simultaneously. This system will be in operation till chlorine gas pressure is above 1.0 kg/cm at the manifold. During this period fresh filled cylinders may be connected to manifold and kept ready for operation. As explained earlier, chlorine pressure started going below 1.0 kg/cm, alarm will be there and manifold l valve in opened thus the operation of auto change over system continues.

NOTE

:- kindly note that when the manifold pressure is 1.0 kg/cm the chlorine tonner is not fully empty there will be at least one or two kg of chlorine will be available. It is not advisable to send chlorine cylinders for refilling with so much of chlorine left over. This left over chlorine shall be exhausted by keeping auto/manual selector switch in manual mode and operate corresponding push button stations and electrically operated valve can be opened. Keep the valve in open position till chlorine pressure comes to 0.2 kg/cm . pressing off push button, valve will be closed. Similar way manifold ll side shall be operated. During this operation no need of opening bypass valves. During manifold-ll is in operation fresh filled tonner may be connected to manifold l and kept ready for auto operation.

View Complete Details

Automatic Changeover System

  • Power Source Electric
  • Voltage Level Low-Voltage, High-Voltage, Medium-Voltage
  • Frequency 50Hz
  • Fluid Media Chlorine Gas

In order to have uninterrupted chlorine gas supply to chlorination system necessary manifolds.Motorised valves and control panel are provided. Chlorine tonner are connected to manifold in which pressure gauge and pressure switch are installed. Pressure gauge indicates the chlorine tonner pressure and pressure switch actuate the electrically operated ball valve. Pressure switch is set at 1.0 kg/cm that means chlorine cylinder is getting empty.
Filled tonner connected to manifold. All tonners valve are kept opened so that manifolds are under pressurized condition. Switch on the auto change over panel and keep the selector switch in auto mode now as soon as panel is energized electrically operated valve manifold I will open first. Even though manifold ll is pressurized , manifold ll side valve will not operate due to inter lock system.
As plant is in operation, chlorine gas will be consumed and tonner pressure may be coming down.When pressure switch actuator and alarm will come and electrically operated ball valve on manifold l will close and valve on manifold ll will open simultaneously. This system will be in operation till chlorine gas pressure is above 1.0 kg/cm at the manifold. During this period fresh filled cylinders may be connected to manifold and kept ready for operation. As explained earlier, chlorine pressure started going below 1.0 kg/cm, alarm will be there and manifold l valve in opened thus the operation of auto change over system continues.

Note :- Kindly note that when the manifold pressure is 1.0 kg/cm the chlorine tonner is not fully empty there will be at least one or two kg of chlorine will be available. It is not advisable to send chlorine cylinders for refilling with so much of chlorine left over. This left over chlorine shall be exhausted by keeping auto/manual selector switch in manual mode and operate corresponding push button stations and electrically operated valve can be opened. Keep the valve in open position till chlorine pressure comes to 0.2 kg/cm . pressing off push button, valve will be closed. Similar way manifold ll side shall be operated. During this operation no need of opening bypass valves. During manifold-ll is in operation fresh filled tonner may be connected to manifold l and kept ready for auto operation.

View Complete Details

Chlorination Systems

38,000 /Set Get Latest Price
see for detail cylinder mounted chlorination system our range of cylinder mounted chlorinator up to 5 kg/hr
View Complete Details

Safety Eye Wash And Shower

  • Shower Extra large drench shower head made of highly visible yellow ABS plastics
  • Pipe ISI marked GI pipe with powder coating for anti-corrosion
  • Valve SS stay open ball valve with yellow ABS push plate
  • Bowl Receptor bowl made of ABS and highly resistant to acid, alkali and oil among others.
  • Activation For shower – Pull rod & For eyewash – Push plate
  • Water inlet and drain 1-1/4 inches BSP
  • Standard IS: 10592:1982

Safety Shower and eyewash operates independently by pull rod and push lever

Automiser heads : Twin soft flow automiser head which has aerators to control the stream straightness and diameter, thus reducing splash by aerating the stream. It also controls to save water and reduce energy costs. The twin flow has cover which protects from dust and opens with water pressure.

View Complete Details

Eye Wash Safety Showers

  • Type Safety Shower
  • Material Stainless Steel
  • Color Multi Colour
  • Finishing Polished
  • Feature Good Quality, Hard Structure, Rust Proof
  • Finishing Color Coated
  • Water inlet and drain 1-1/4 inches BSP

Description

  • Safety Shower and eyewash operates independently by pull rod, hand push lever and foot lever
  • Shower - Extra large drench shower head made of highly visible yellow ABS plastics
  • Pipe - ISI marked GI pipe with powder coating for anti-corrosion
  • Valve - SS stay open ball valve with yellow ABS push plate
  • Bowl - Receptor bowl made of ABS and highly resistant to acid, alkali and oil among others.
  • Automiser heads - Twin soft flow automiser head which has aerators to control the stream straightness and diameter, thus reducing splash by aerating the stream. It also controls to save water and reduce energy costs. The twin flow has cover which protects from dust and opens with water pressure
  • Activation - For shower – Pull rod; For eyewash – Push plate/ Foot paddle
  • Water inlet and drain - 1-1/4 inches BSP
  • Standard - IS- 10592:1982
View Complete Details

Trunnion Roller

These help in the proper placement of tonners and to rotate the ton container easily for positioning the gas valves

View Complete Details

Trunnion Roller Support

  • Type Roller Support
  • Material Iron, Metal
  • Application Industrial
  • Feature Corrosion Resistance, Heavy Weight Bearing Capacity, High Quality, Non Breakable
  • Finishing Polished
  • Technics Yellow Zinc Plated

These help in the proper placement of tonners and to rotate the ton container easily for positioning the gas valves.