Our Products
MCB can be used for protection of circuits against short-circuit currents, protection of circuits against overload currents.
HIGH PERFORMANCE VALUES OF MCB
BENEFITS:
FEATURES:
BENEFITS:
APPLICATIONS:
Isolators can be used for electrical isolation they combine the following functions:
BENEFITS:
APPLICATIONS:
Positive disconnection of electrical circuit in order to under go maintenance of downstream circuit in:
FEATURES:
BENEFITS:
Get the performance you need, at a cost-effective investment, with the quality you demand:
APPLICATIONS:
Air Circuit Breakers are ideal for variety of applications & designed for protection & measurement of electrical distribution networks.
FEATURES:
APPLICATIONS:
APPLICATIONS:
FEATURES:
APPLICATIONS:
FEATURES:
BENEFITS:
BENEFITS:
APPLICATIONS:
KEIindustries has launched its new range of Flame retardant PVC insulated wires for domestic household applications -homecab.
Especially designed for domestic house hold usage, Homecab a multi-strand flexible house wires with fire resistant properties are equipped with specially formulated insulation, with a high oxygen and temperature index, enables the cable to withstand overloads preventing electric mishaps.
KEI INDUSTRIES LIMITEDis manufacturingLT POWER CABLESwith PVC or XLPE insulation of voltage grade upto 3.3 KV conforming to various Indian and International Standard Specifications.KEIalso manufactures other types of cables as listed at the end of this catalogue.
These winding wires have very thin insulation thickness which makes them useful in smaller submersible pumps such as V4 pumps. The old pumps are to be rewound the stator slots get smaller and they require thinner winding wires.
CROSS LINKED POLYETHYLENE (XLPE) :-
ONTROL CABLESare primarily used in all types of electric utilities, industrial and commercial markets.
These products are mainly used inMACHINERY, MACHINE TOOLS AND APPLIANCES, MEASURING, CONTROL, HEATING AND AIR CONDITIONING TECHNOLOGIESfor permanent connections in cable chains, etc.
The halogen-free cables and wires are internationally certified and you can choose from our comprehensive range of standard products or can ask for cables / wires with special properties to meeting your requirement.
The state-of-the-artEXTRA HIGH VOLTAGE (EHV)cable plant with German technology manufactures cables up to 220kV. There are two CCV lines for the same:
Both the above mentioned manufactures are well-known names inCCV LINES TECHNOLOGYand have supplied more than 250 lines world over. The triple extrusion and DCDC process ensure contamination-free cores.
All three layers are well-bonded and the core has very less eccentricity and ovality. The insulation itself is free of micro voids and has negligible moisture content.
KEImanufactures HT cables up to 220KV conforming to National and International Standards at Bhiwadi plant.KEIhas State of Art HT cable plant with German technology. The manufacturing capability is upto 220KV.
HT plant is complete with heavy duty machines for wire drawing and conductor making, laying up, armouring , sheathing and packing.
The process commences with a compacted circular conductor being fed from the pay off stands into the extruder on elevated platform. The conductor passes through extruders crosshead, it is covered first with semiconducting screen layer then the XLPE insulation, followed by the outer semiconducting core screen. This crosshead is specially designed to feed three compounds from three extruders at one point described as Singe point Triple extrusion.
Thereafter, the extruded core enters and passes through vulcanizing line known as CCV line (Continuous Catenary Vulcanising) and the XLPE insulated core is cured in the process. In CV line inert atmosphere is maintained by the Nitrogen gas which is at high pressure and high temperature.
This process is popularly known as Single point Triple extrusion CDCC(Completely Dry Cured and Cooled Curing)
In keeping with the companys commitment to technological advancement, elastomer materials such as Polychloroprene (PCP), Chloro-Sulphoneted Polyethelene (CSP), Nitrile Rubber / PVC blends, Ethylene Propelene Rubber (EPR), Ethylene Vinyle Acetate (EVA) and Silicone have been specially compounded to meet numerous heat oil and fire resisting requirements. In the recent years KEI has also developed special Elastomeric Fire Survival Cables for power, control and instrumentation wiring.
Elastomeric compounds for insulating and sheathing of cables are formulated to meet the requirement ofIS 6380, BS 6899, IEC 60502and other international specification.
GENERAL CONSTRUCTION (CONFORMING TO IS 9968 PART 1)
KEI INDUSTRIES LIMITEDmanufactures a wide variety of cables suitable for process instrumentation. In the projects related to power generation & distribution, chemical & fertilizer industries and various other types of engineering industries, the process instrumentation plays a vita role in measurement, supervision and control of the process.
All this means that the cables to be used for instrumentation should be designed and manufactured very carefully, KEIwith its meticulous efforts in maintaining quality, stringent in process control during manufacture and the knowledge of cable designing, is proud to say that it is capable of supplying instrumentation cables meeting any Indian/International standard or a specific requirement desired by project authority.
The efforts done byKEIare reqarded by acceptance of our quality by the country's prime organisations such asNTPC, PDIL, EIL, BHEL, TATA'S, IOCL, L&T, ABB, KRUPP IND, BPCL., HPCL, ESSAR, SIEMENS, ELECTRICITY BOARDS, RELIANCE, IOTL, MUKAND, HONEYWELL, ETC.
These cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to paired instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control.
The thermocouple and pyrometers are electrically conducted byTHERMOCOUPLE EXTENSION/COMPENSATING CABLES.The conductors used for these cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature. The cables are manufactured as perIS:8784, ANSI-MC 96. 1, B.S., ENI, DIN AND CUSTOMERS SPECIFICATION.