1. Specifications:- Display : 4 digits, LCD display.Range : Moisture Content: 0-50%Temperature : 16-65 CResolution: 0.1%Accuracy : Moisture Content: (0.5%)Temperature: 0.9 C 2. Measuring Procedure:- (i) Hold the handle measurement needles and leave needles in the air, i.e. dont let needles touch anything except air.(ii) Set the Function Switch to the Moisture Content (H2O)position to switch on the power supply.(iii) You will hear 2 times of click sound. That is self-calibration by the instrument.(iv) Insert two steel measurement needles into the paper or box in correct way to be measured. The reading on the Display is the measurement value.(v) Hold : To keep the maximum value, just push the Hold button for a while, the symbol max will appear on the display. To cancel the hold value, just push Hold button again for a while when the symbol max disappears.
Additional Information:
Payment Terms :
L/C, T/T, Western Union
Packaging Details : Wooden Packing