We offer a complete product range of Siemens QFM2160 Duct Temperature Humidity Sensor, Ethernet Bacnet IP MS Server Gateway, Siemens GLB141.1E Rotary Air Damper Actuator, Belimo 22dtm-1106 Duct Sensor co2 Humidity Temperature and Landis Gyr Ultrasonic Btu Meter

Modbus Rtu To Modbus Tcp Router

  • Number Of Flower Router
  • Model INMBSRTR0320000
  • Throughput 1 Gbps
  • Interface RS 485
  • Serial Port Number 1
  • Terminator for RS- 485
  • Modbus Type Modbus TCP/IP
Integrate devices in a Modbus RTU network with a Modbus TCP network transparently with our compact Modbus Router. This integration aims to make Modbus RTU devices, registers, and resources accessible to a Modbus TCP client BMS or controller.
View Complete Details

Ethernet Bacnet IP MS Server Gateway

  • Interface Ethernet
  • Serial Port Number 2
  • Throughput 100 Mbps
  • IP Access method Intesis MAPS
  • Ethernet Ports 2 Ports
  • Power Supply 24VDC
  • Operating Temperature 0 DegreeC to +60 DegreeC
EtherNet/IP - BACnet IP & MS/TP Server GatewayThe Intesis BACnet-EtherNet/IP gateway allows you to seamlessly inter-connect PLC/BMS systems and their connected devices between BACnet IP&MSTP Control systems and EtherNet/IP networks.This gateway works as a BACnet slave/server on the BACnet side and as a EtherNet/IP adapter on the EtherNet/IP side.
View Complete Details

Integrate Modbus Rtu Tcp Server Device

  • Application IOT
  • Throughput 100 Mbps
  • Interface RS 485
  • Modbus Type Modbus RTU
  • IP Access method MAPS
  • Model Name/Number IN700
  • Ethernet Ports 1 Port
  • Serial Port Number 2
  • Number Of Ports 3
Modbus TCP & RTU Master to BACnet IP & MS/TP Server Application Integrate any Modbus RTU or TCP server device, or both at the same time, with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. The aim of this integration is to make accessible Modbus system signals and resources from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa. FEATURES UL Certified BTL Certified Support for BACnet IP Client and MSTP Master BACnet Advanced features available (Trend logs, Calendars, etc.) Support for 2 independent RTU ports for integration into BACnet IP
View Complete Details

M-BUS To Modbus Tcp Server Gateway

  • Application IOT
  • Model INMBSMEB0200100
  • Throughput 1 Gbps
  • Interface Ethernet
  • Serial Port Number 1
  • Modbus Type Modbus TCP/IP
  • Dimensions (with ears) 100 x 60 x 70mm
  • IP Access method Intesis MAPS
  • Ethernet Ports 1 Port
  • Power Supply 24VDC
  • Operating Temperature 0-60 Deg.C
Integrate any M-Bus device with Modbus. The aim of this integration is to make accessible M-Bus devices, its registers and resources from a Modbus-based control system or device as if it was a part of the own Modbus system and vice-versa. FEATURESUL Listed.Scan: Automatic identification of M-Bus devices (meter detection) and registers discovery.Embedded M-Bus level converter.Up to 5 TCP clients (incoming sockets) are supported.Supports Modbus TCP physical layer.Configuration through IP (Console) port.Easy integration with Intesis MAPS.Automatic updates for both Intesis MAPS and the interfaces firmware.
View Complete Details

Profinet Bacnet IP MS Server Gateway

  • Interface Ethernet
  • Serial Port Number 1
  • Throughput 100 Mbps
  • Modbus Type Modbus TCP/IP
  • Usage/Application Industrial
  • IP Access method MAPS
  • Model Name/Number INBACPRT1K20000
  • Ethernet Ports 1 Port
  • Power Supply 24VDC +/-10% Max.580mA
The Intesis BACnet-PROFINET gateway allows you to seamlessly interconnect PLC/BMS systems and their connected devices between BACnet/IP and MS/TP control systems and PROFINET networks. The gateway works as a BACnet server on the BACnet side and as a PROFINET I/O device on the PROFINET side and is configured via the Intesis MAPS configuration tool.
View Complete Details

Ocpp To Modbus Tcp Rtu Server Gateway

  • Application Industrial
  • Throughput 100 Mbps
  • Interface Ethernet
  • Modbus Type Modbus TCP/IP
  • IP Access method MAPS
  • Model Name/Number INMBSOCP0010100
  • Ethernet Ports 1 Port
  • Power Supply 9-36 VDC
OCPP to Modbus TCP & RTU Server GatewayIntegrate Electric Vehicles Charging points based on OCPP 1.6 with any Modbus RTU or TCP controller or connect the chargers to an external OCPP Central System (CS) and monitor them via Modbus. This gateway offers 2 type of OCPP functionalities configurable in MAPS tool:
View Complete Details

M-BUS To Bacnet/IP Server Gateway

  • Application Industrial
  • Material UL 94 V-0
  • Network Type TCP/IP
  • Model Name/Number M-BUS to BACnet IP & MS/TP Server Gateway
  • Input Voltage 24VDC
Integrate any M-Bus device with BACnet. The aim of this integration is to make accessible M-Bus devices, its registers, and resources from a BACnet-based control system or device as if it was a part of the own BACnet system and vice-versa.
View Complete Details

Knx Tp To Bacnet IP MS Server

  • Application Industrial
  • Interface RS 485
  • Serial Port Number 2
  • Throughput 100 Mbps
  • Modbus Type Modbus RTU
  • IP Access method MAPS
  • Ethernet Ports 1 Port
KNX TP to BACnet IP & MS/TP Server ApplicationIntegrate any KNX device or installation, with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. The aim of this integration is to make accessible KNX communication objects and resources from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa.
View Complete Details

Ocpp To Modbus Tcp & Rtu Server Gateway- 20 Chargers

  • Number Of Flower Router
  • Application Industrial
  • Interface Ethernet
  • Serial Port Number 1
  • Throughput 100 Mbps
  • Modbus Type Modbus TCP/IP
  • Model Name/Number INMBSOCP0200100
  • Ethernet Ports 1 Port
  • Power Supply 9-36 VDC
OCPP to Modbus TCP & RTU Server GatewayIntegrate Electric Vehicles Charging points based on OCPP 1.6 with any Modbus RTU or TCP controller or connect the chargers to an external OCPP Central System (CS) and monitor them via Modbus. This gateway offers 2 type of OCPP functionalities configurable in MAPS tool:
View Complete Details

Knx Tp To Modbus Tcp Rtu Server Gateway

  • Throughput 100 Mbps
  • Interface Ethernet
  • Serial Port Number 2
  • Modbus Type Modbus TCP/IP
  • Dimensions (with ears) 99 x 88 x 56 mm
  • Backplane Current Load 180mA
  • Model Name/Number IN701KNX1000000
  • Ethernet Ports 1 Port
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed. The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer
View Complete Details

M-BUS To Modbus Tcp & Rtu Server Gateway

  • Application Industrial
  • Interface RS 485
  • Serial Port Number 2
  • Modbus Type Modbus TCP/IP
  • Terminator for RS- 485
  • Model Name/Number M-BUS to Modbus TCP & RTU Server Gateway - 20 devices
  • Power Supply 24VDC
  • Network Type TCP/IP
  • Number Of Ports 2
  • Ethernet Ports 1
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available projecttemplates or to import any created/exported project template on your computer.
View Complete Details

Lonworks Tp To Bacnet IP Tp Server Gateway

  • Application IOT
  • Interface RS 485
  • Serial Port Number 2
  • Throughput 100 Mbps
  • Modbus Type Modbus TCP/IP
  • IP Access method MAPS
  • Ethernet Ports 1 Port
  • Power Supply 24VDC
Integrate any LON device or installation, with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. The aim of this integration is to make accessible LON devices, its network variables (SNVT) and resources from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa.
View Complete Details

Dali To Modbus Tcp Server Gateway

  • Model INMBSDAL0640500 1 DALI Channel)
  • Application IOT
  • Dimensions (with ears) Net dimensions (dxwxh): 88x106x56 mm
  • Power Supply 24VDC/AC +/-10% 6W(250mA)
  • Operating Temperature 0 DegreeC to +50 DegreeC
  • Ethernet Ports 1 x Ethernet 10/100 Mbps RJ45
  • Relative Humidity 5 to 95%, no condensation
  • Number Of Ports 1
Integrate any DALI/DALI-2 driver and DALI-2 light sensor, or occupancy sensor with a Modbus BMS or any Modbus TCP controller. The aim of this integration is to make DALI devices and its data and resources accessible from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
View Complete Details

Bacnet IP MS Tp Client To Modbus Gateway

  • Interface Ethernet
  • Serial Port Number 2
  • Throughput 100 Mbps
  • Modbus Type Modbus TCP/IP
  • IP Access method MAPS
  • Ethernet Ports 1 Port
Integrate any BACnet MS/TP or BACnet IP server device, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible BACnet objects data and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
View Complete Details

Bacnet MS/tp To Bacnet IP Router

  • Number Of Flower Router
  • Application Industrial
  • Packaging Type RAL 7035
  • Throughput 100 Mbps
  • Model Name INBACRTR0320000
  • Power Supply 9-36 VDC
  • Operating Temperature 0 DegreeC to +60 DegreeC
  • Ethernet Ports 1
BACnet MS/TP to BACnet IP RouterIntegrate BACnet MS/TP with BACnet IP devices with our BACnet Router. It is a compact BACnet multi-network device which provides smooth routing between BACnet/IP and BACnet MS/TP networks. The aim of this integration is to make accessible BACnet devices, its objects and resources independently of the BACnet network they are connected.FEATURESUL CertifiedBTL CertifiedSupport for up to 32 full-load MS/TP devicesSupport for BBMD network roleBACnet Explorer featureBACnet network diagnose signals available in MAPS and as BACnet objectsEasy integration & updates with Intesis MAPS
View Complete Details

Modbus Tcp Rtu To Bacnet IP Server Gateway

  • Application IOT
  • Interface RS 485
  • Serial Port Number 1
  • Modbus Type Modbus RTU
  • Terminator for RS- 485
  • IP Access method MAPS
  • Model Name/Number INBACMBM1000100
  • Ethernet Ports 1 Port
  • Power Supply 24VDC
Modbus RTU Master and Modbus TCP ClientThe gateway acts as a BACnet/IP Server device in its BACnet interface, allowing other BACnet devices to perform subscription (COV) requests and reads/writes to its internal points. From the Modbus point of view, Intesis simulates a Modbus RTU Master device and or Modbus TCP Client device. Readings of the Modbus slave device(s) is performed by Intesis by automatic continuous polling.
View Complete Details

Dali To Bacnet IP Server Gateway

  • Model Name/Number INBACDAL0640500 1 DALI channel
  • Power Supply 24VDC/AC +/-10% 6W(250mA)
  • Operating Temperature 0 DegreeC to +50 DegreeC
  • Ethernet Ports 1 x Ethernet 10/100 Mbps RJ45
  • Number Of Ports 1
Integrate any DALI/DALI-2 driver and DALI-2 light sensor, or occupancy sensor with a BACnet BMS or any BACnet IP controller. The aim of this integration is to make DALI devices and its data and resources accessible from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa.
View Complete Details

Rotronic Xd33a-s3x Standard Versions Humidity Transmitters

  • Brand Name ROTRONIC
  • Country of Origin 5 16 VAC 5 24 VDC
  • Application Pharma
  • Minimum Order Quantity 1 Piece
  • Model Name/Number ROTRONIC XD33A-S3X STANDARD VERSIONS
  • Measuring Parameter relative humidity & temperature
  • Operating Range 5 16 VAC 5 24 VDC
  • Warranty 1 yrs.
Measures relative humidity & temperature Calculates dew/frost point Power supply range: 516 VAC / 524 VDC Outputs: 0.1 V / 0.5 V / 0.10 V (standard probes) 0.1 V / 0.5 V / 0.10 V / 0.20 mA / 4.20 mA (industrial probes) Voltage outputs configurable via software Highest precision and reproducibility Excellent long-term stability
View Complete Details

Temperature Humidity Co2 Sensor Modbus

  • Application ROOM OPERATING UNIT
  • Material PC White RAL 9003
  • Humidity Accuracy +-2%
  • Operating Temperature 0.50 DegreeC [32.122 DegreeF]
  • Protection Class IP30
  • Interface RS 485
  • Serial Port Number 1
  • Modbus Type Modbus RTU
  • Parameter To Be Monitored CO2, Temperature, Relative humidity, Dew point
  • Connection Modbus RTU BACnet MS/TP MP-Bus
  • Dimensions 69x62 mm
  • Display Type ePaper touch display
  • Model Name/Number P-22RTM-1U00D-2
  • Power Source AC/DC 24 V
  • Voltage AC/DC 24 V
Nominal voltage AC/DC 24 VNominal voltage range AC 19.2.28.8 V / DC 19.2.28.8 VPower consumption AC 1 VAPower consumption DC 0.5 WElectrical connection Spring loaded terminal 0.25.1.5 mmCable entry Back sideTop sideBottom side
View Complete Details

Siemens GLB141.1E Rotary Air Damper Actuator

  • Material Aluminium
  • Product Code GLB141.1E
  • Running Time 150
  • Control Signal 0-10vdc
  • Room Type Commercial Space
GLB141.1E Rotary air damper actuator, AC/DC 24 V, 2-position/3-position, 10 Nm, 150 sFor shaft dia. 8.16 mm, square 6.12 mm, min. shaft length 30 mmWith position indication and adjustable mechanical limit stopButton for disengaging the gear train to enable manual overrideWith base made of steel, plastic housing and 0.9 m connecting cable
View Complete Details

Belimo 22DTH-13M Duct Temperature & Humidity Sensor

  • Number Of Flower Digital Temperature Sensor
  • Humidity Accuracy +-2% RH
  • Temperature Accuracy +-0.2 Deg C
  • Humidity range 0 to 100% RH
  • Temperature Range -20.80
  • Part Number 22DTH-13M
  • Brand Name BELIMO
  • Country of Origin Made in India
  • Payment Mode Online
  • Packaging Type Box
  • Connectivity Type Wire
Voltage -AC/DC DC 24 VElectrical connection -TerminalsMeasured values -Temperature HumidityOutput signal -4.20 mA Measuring range humidity -0.100% RH non-condensingOutput Current [Range] -2x 4.20 mA, max. resistance 500 Probe length -140 mm
View Complete Details

Landis Gyr Ultrasonic Btu Meter

  • Application Industrial
  • Display Type BACLIT
  • Brand Name Landis+Gyr
  • Display Digital
  • Model Name/Number UH50-UH30
  • Technique ULTROSONIC
  • Is It Portable Non Portable
  • Output M-BUS , MODBUS
  • I Deal In New Only
Measuring accuracyClass 2 or 3 (EN 1434)Environment classA (EN 1434) for indoor installationMechanical classM1 *)Electromagnetic classE1 *)*) according to 2014/32/EU Directive on Measuring InstrumentsAmbient humidity< 93 % rel. humidity at 25C, without condensationMax. height2000 m above sea levelStorage temperature-20 60 C Electronic unitAmbient temperature5 55CHousing protection ratingIP 54 according to EN 60529Safety classLine 110 / 230 V ACII according to EN 61558Line 24 V ACDCIII according to EN 61558Operation threshold f. T0.2 KTemperature difference T3 K 120 KTemperature measurement range0 . 180CLCD7 digitOptical interfaceStandard, EN 62056-21CommunicationOptional, e. g. M-BusSeparabilityAlways, optional cable length Temperature sensorTypePt 500 or Pt 100According to EN 60751Temperature range0 . 150C(up to 45 mm overall length)0 . 180C(from 100 mm overall length) Volume measurement unitProtection classIP 54 / IP 65 / IP 68 according to EN 60529According to EN 60529Mounting placeHot side / cold sideInstallation positionAnyFlow straighteningNoneMeasuring range1:100Temperature range5 130CNational type approvals may be differ-ent.Recommended.heating application10 130C.cooling application5 50CMaximum overload2, 8 qpNominal pressurePN16 (PS16), PN25 (PS25)
View Complete Details

Belimo 22DTH-11M Duct Temperature & Humidity Sensor

  • Number Of Flower Digital Temperature Sensor
  • Humidity Accuracy +-3% RH
  • Temperature Accuracy +-0.2 Deg C
  • Brand Name BELIMO
  • Temperature Range 22DTH-11M
  • Output 0-5V 0-10 V
  • Supply Voltage AC/DC 24 V
  • Number of Pins 4 Pins
SpecificationsVoltage AC/DC -AC/DC 24 VElectrical connection -TerminalsMeasured values -Temperature HumidityOutput signal -0.5 V 0.10 VMeasuring range humidity -0.100% RH non-condensingOutput Voltage [Range] -2 x 0.5 V, 0.10 V, min. resistance 10 kOutput signal active note -Output 0.5/10 V with Jumper adjustableProbe length -140 mm
View Complete Details

Siemens QFM2160 Duct Temperature Humidity Sensor

  • Humidity Accuracy 3% RH
  • Number Of Flower Humidity & Temperature Sensor
  • Humidity range 10 to 90 % RH
  • Brand Name Siemens
  • Application Temperature Measurement
  • Model Name/Number QFM2160
View Complete Details

Outdoor Sensor With Weather And Radiated Heat Shield Humidity / Temperature

  • Application Outdoor
  • Humidity Accuracy +-2% between 0.80% RH @ 25 DegreeC
  • Parameter To Be Monitored Temperature and Humidity
  • Connection Pluggable spring loaded terminal block
  • Model Name/Number 22UTH-130X
Voltage AC/DC-DC 24 VElectrical connection -TerminalsMeasured values -Temperature HumidityOutput signal -4.20 mAMeasuring range humidity - 0.100% RH non-condensingOutput Current [Range] -2x 4.20 mA, max. resistance 500
View Complete Details

Belimo 22dtm-1106 Duct Sensor Co2 Humidity Temperature

  • Number Of Flower Digital Temperature Sensor
  • Brand Name BELIMO
  • Humidity Accuracy +-2% RH
  • Temperature Accuracy +-0.2 Deg C
  • Part Number 22DTM-1106
  • Humidity Range 0 to 100% RH
  • Temperature Range 0.50 DegreeC [32.122 DegreeF]
  • Output 0.5 V 0.10 V
  • Supply Voltage AC/DC 24 V
Voltage AC/DC -AC/DC 24 VElectrical connection -TerminalsMeasured values - CO Temperature HumidityOutput signal -0.5 V 0.10 VMeasuring range CODefault setting: 0.2000 ppmWith A-22G-A05: 0.5000 ppmMeasuring range humidity0.100% RHMeasuring range temperature0.50C [32.122F]Output Voltage [Range]3 x 0.5 V, 0.10 V, min. resistance 10 kOutput signal active noteOutput 0.5/10 V with Jumper adjustableDisplay type -LCDProbe length -180 mm
View Complete Details

Siemens Digital Room Thermostat

  • Temperature Range 5.40 DegreeC
  • Application HVAC
  • Brand Name SIEMENS
  • Size 86 x 86 x 57 mm
  • Description Modbus RTU (RS 485)
  • Model Name/Number RDF302
Flush-mount room thermostat for rectangular conduit box with Modbus communications, 2-/4-pipe fan coils or DX type equipment Modbus communications For heating and/or cooling applications 2 or 3-position control outputs Output for 1-speed or 3-speed fan 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact Operating modes: Comfort, Economy and Protection Automatic or manual heating/cooling changeover Adjustable commissioning and control parameters Minimum and maximum setpoint limitation Color of housing: signal white (RAL 9003) Backlit display
View Complete Details

Belimo 22DTH-15M Duct Temperature & Humidity Sensor

  • Humidity Accuracy +-3% RH
  • Number Of Flower Digital Temperature Sensor
  • Accuracy +-2% RH
  • Temperature Accuracy +-0.2 Deg C
  • Humidity range 0 to 100% RH
  • Brand Name BELIMO
  • Part Number 22DTH-15M
  • Temperature Range -20.80 DegreeC
  • Measuring Parameter Temperature and Humidity
  • Usage/Application Pharma
  • Model Name/Number 22DTH-15M
View Complete Details

Belimo 01DT-1LP Duct/immersion Sensor Temperature Passive, NTC10k (10k2)

  • Number Of Flower Temperature Sensor
  • Material Stainless Steel, Brass
  • Probe Length 200 Mm
  • Usage Measuring Temperature In Duct And Pipe Applications

Duct/Immersion sensor Temperature passive, NTC10k (10k2), Probe length 200 mm, Probe diameter 6 mmFor measuring temperature in duct applications. In connection with a stainless steel or brass thermowell also applicable for pipe applications. IP65 / NEMA 4X rated enclosure.

View Complete Details

Siemens QFA2060 Humidity & Temperature Sensor

  • Brand Name SIEMENS
  • Number Of Flower Humidity & Temperature Sensor
  • Minimum Order Quantity 1 Piece
  • Humidity Accuracy +-3% RH
  • Measurement Range 0% to 100% RH
  • Humidity Range 0 to 100% RH
  • Protection class IP30
Signal output humidityDC 0.10 VSignal output temperatureDC 0.10 VOperating voltageAC 24 V, DC 13.535 VSensing element, temperatureDC 0.10 VMeasuring range, temperature050 C, -3535 C, -4070 CMeasurement range humidity095 % r.h.Measurement accuracy23 C: 23 % r.h., 095 % r.h.: 5 % r.h.At 23 C, 3070 % r.h.: 5 % r.h.Time constantHumidity: 20 s, Temperature: 510 sDimensions (W x H x D)90 x 100 x 36 mm
View Complete Details

Universal IR AC To Rtu Bacnet Mstp Interface Modbus Gateway

  • Application For Office
  • Humidity Accuracy +-3% RH
  • Temperature Accuracy +-0.5 Deg C
  • Model Name/Number IN485UNI001I100
  • Number Of Ports/Pins 1
  • Humidity Range 10 to 90 % RH
  • Temperature Range 0-50 deg.C
  • Output MODBUS RTU
  • Supply Voltage 1 x Mini-USB Type Mini B. Power consumption: max. 400mA @ 5 Vdc
  • Operating Temperature 0 to 50 Deg C
  • Dimensions (W x H x D) 93 x 60 x 21 mm
Energy savings and efficiency, smart AC control Use 365-day scheduling calendars, presence detectors, or window contacts to execute automated scenes, optimizing energy usage. Feedback from the AC unit The gateways built-in IR receiver reads the handheld remote controller commands and reports the AC unit 's status to AC Cloud Control. This enables bidirectional communication
View Complete Details

Daikin Vrv Sky Systems To Rtu Interface Modbus Gateway

  • Interface RS 485
  • Serial Port Number 1
  • Modbus Type Modbus RTU
  • IP Access method MAPS
Daikin VRV and Sky systems to Modbus RTU InterfaceThe Daikin-Modbus gateway allows fully bi-directional communication between Daikin VRV and Sky systems and Modbus RTU (RS-485) networks. FEATURES Modbus RTU (EIA485) slave device.Configuration from both onboard DIP-switches and Modbus RTU.Quick and easy installation (plug and set the DP-SW).External power not required.Simultaneous control of the AC unit by the IR remote controller and by Modbus RTU.Reduced dimensions 93 x 53 x 58 mm.Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.Window contact function allows energy savings. Costs related to HVAC systems in a building are one of the highest and this type of functions allow to reduce them.Total control and monitoring of the AC unit from Modbus RTU, including AC units internal variables, running hours counter (for filter maintenance control) and error indication
View Complete Details

Bosch Vrf Systems To Rtu Interface Modbus Gateway

  • Interface RS 485
  • Serial Port Number 2
  • Modbus Type Modbus RTU
  • IP Access method MAPS
Bosch Commercial & VRF systems to Modbus RTU InterfaceThe Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks. FEATURES Modbus RTU (EIA485) slave device.Configuration from both onboard DIP-switches and Modbus RTU.Quick and easy installation (plug and set the DP-SW).Simultaneous control of the AC unit by the IR remote controller and by Modbus RTU.Reduced dimensions 93 x 53 x 58 mm.Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.Window contact function allows energy savings. Costs related to HVAC systems in a building are one of the highest and these type of functions allow to reduce them.Total control and monitoring of the AC unit from Modbus RTU, including AC units internal variables, running hours counter (for filter maintenance control) and error indication
View Complete Details

Digital Input Module

  • Brand Name TROPOSPHAIRA
  • Power 12-24 VAC DC
  • Frequency 50Hz
  • Country of Origin 12024 VDC AC
  • Country of Origin Made in India
  • Current 0.1 A
  • Model Name/Number TP-16DI
  • No. Of Channels 16
  • Dimensions L110XH110XB50MM
  • Instrument Type DIGITAL INPUT MODULE
  • Network Speed 9600 - 115200 bps
  • Number Of Ports/Pins 1
  • Communication MODBUS
  • Type Of Mounting DIN Rail
  • Ambient Temperature 0 - 60
IO Module with 16 Port DI with Dual detection ( voltage detection 3 - 40 V DC or potential free detection with on board 12 V DC ref) and Modbus RS485 interface. SW for Slave ID and Baud rate selection. Closed DIN rail mountable enclosure.
View Complete Details

Tailgating Detector Modbus Gateway

  • Application Detect Events and Changes In the Environment
  • Country of Origin Made in India
  • Frequency Mode Fixed-Frequency Emission Mode
  • Type Of System TAILGATE DETECTOR
  • Model Name/Number DG001
  • Voltage 12VDC
  • Infrared Diodes Range 2000mm
  • Installation Type Wall Mounted
  • Number Of Sensors 4
  • Connectivity Type Wired
  • Operating Temperature -10 to +60 Degree Celcius
  • Battery Backup W/O Battery
  • Power Supply 12 VDC
Door Guard (DS01) is doorway-mounted tailgate detection system that further secures an access controlled door. Operation Door Guard (DG01) protects employees and valuable assets by improving the security of any access-controlled door and maximizing the security investment. When access is granted, one person can pass through the doorway without alarm. Door Guard (DG01) monitors how many people pass and for each valid authorization, and sounds an alarm if there is a violation. An optional programmable relays can also activate subsequent actions such as triggering CCTV or local hooter. Door Guard (DG01) should be considered for critical areas where an intruder could slip through undetected. Advanced Intelligence Door Guard uses a network of beam paths to make smart alarm conclusions about movement through an open door. Real-time annunciation helps access control anti-pass back policy enforcement, allowing event alarms to be activated upon unauthorized entry.
View Complete Details